ID Topic Issue Status Round Comment By Initial Date
1 Electric [2/9/06] No comments, assuming there is no change in electric service
requirements. If a change is necessary, contact Light & Power Engineering
at 221-6700.
Active 1 Doug Martine 02/09/2006
2 ZONING [2/9/06] In the response letter dated Feb 7, 2006, Comment 1B it states that
there is no parking proposed in the development, yet the site/landscape plan
clearly shows parking. 73 parking spaces.
Resolved 1 Jenny Nuckols 02/09/2006
3 ZONING [2/9/06] What parking spaces will be used for auto display/storage and what
spaces for customer parking? Please note on the site plan.
Resolved 1 Jenny Nuckols 02/09/2006
4 ZONING [2/9/06] I don't see a trash enclosure noted anywhere on the site plan. How
will trash and recyclables be handled?
Resolved 1 Jenny Nuckols 02/09/2006
5 ZONING [2/9/06] Make note of the parking stall dimensions on the site plan. Resolved 1 Jenny Nuckols 02/09/2006
6 ZONING [2/9/06] NOTE: one of the handicap spaces needs to be van accessible: 16'
overall width with a sign at the head of the space denoting it as van
accessible
Resolved 1 Jenny Nuckols 02/09/2006
7 ZONING [2/9/06] Is there a fence along the east property line to screen the building
and parking from the adjacents properties? 3.2.1(E)(4)(b)
Resolved 1 Jenny Nuckols 02/09/2006
8 General [2/10/06] Please show the 20' access easement on the site plan. Resolved 1 Shelby Joy 02/10/2006
9 General [2/10/06] How much parking is provided for the car rental business? How
much parking is provided for each of the other 3 uses? Please differentiate
on the site plan.
Resolved 1 Shelby Joy 02/10/2006
3/7/2011 Page 1
Project: 4900 SOUTH COLLEGE AVENUE PDP, CHANGE OF USE - TYPE II
ID Topic Issue Status Round Comment By Initial Date
11 General [2/10/06] Contact me for the appropriate signature blocks to include on the
site plan. Aerial context diagram is unnecessary on stie plan, just keep the
vicinity map.
Resolved 1 Shelby Joy 02/10/2006
12 General [2/10/06] West elevation should be enlarged to a legible scale. Resolved 1 Shelby Joy 02/10/2006
14 Traffic [2/15/06] No further traffic analyses is required. The projected use of the
facility is similar to the past use.
Active 1 Eric Bracke 02/15/2006
15 General [6/1/06] The plans are still not clear as to whether there is an existing ramp
at the corner of the frontage road and Fairway Lane. If there is not one, this
project will need to construct one.
[4/5/06] Just keeping this comment in for coordination and papertrail.
[2/28/06] The City will not require any upgrades to the existing sidewalk
along either the frontage road or Fairway. This project will only have to
replace and/replace any existing damaged curb, gutter, ramp and/or
sidewalk.
Active 1 Susan Joy 02/28/2006
16 General [6/1/06] Existing easements previously dedicated by separate documents
need to be labeled as such with the reception number. Please see redlines.
[4/5/06] Easement dedications are still not correctly labeled on the plan (the
frontage road sidewalk access easement is not shown).
[2/28/06] Please label and dimension all existing easements as "existing"
and all proposed easements as "proposed". Must provide legals and exhibits
of all easements to be dedicated with the next submittal along with a $250
processing fee for each dedication. Larimer County filing fees are due prior
to the actual filing of the dedications.
Active 1 Susan Joy 02/28/2006
17 General [2/28/06] A 20' access easement along the east side of the property must be
dedicated to accommodate the future "rearage" road and it may not overlap
the existing 10' Trail Easement. There is some possibility that the 20' access
easement has already been dedicated and the 10' trail easement is really on
the property to the east. The developer/consultants will need to research this
further.
Resolved 1 Susan Joy 02/28/2006
18 General [2/28/06] Will need access easements for all public sidewalks outside of the
right of way along Fairway and the Frontage Road.
Resolved 1 Susan Joy 02/28/2006
3/7/2011 Page 2
Project: 4900 SOUTH COLLEGE AVENUE PDP, CHANGE OF USE - TYPE II
ID Topic Issue Status Round Comment By Initial Date
19 General [2/28/06] Please label the existing sidewalk width along Fairway. Current
standards require a 4.5 sidewalk minimum. You may add on to a sidewalk
equal to 1/2 the existing width (and dedicate the additional access easement
beyond the row) OR you may remove the existing walk and replace it to the
required 4.5' width.
Resolved 1 Susan Joy 02/28/2006
20 General [2/28/06] The attached walk along the Frontage Road needs to be widened
out to a 6' attached walk. An access easement must be dedicated for the
portion of the sidewalk outside of row. Please provide a legal and exhibit for
our review and approval along with a $250 processing fee.
Resolved 1 Susan Joy 02/28/2006
21 General [2/28/06] Are the drainage easements existing? Proposed? If proposed,
please provide a legal and exhibit for each easement for our review and
approval along with $250 processing fee for each. The detention pond area
needs to be dedicated as a Drainage Easement as well.
Resolved 1 Susan Joy 02/28/2006
22 General [2/28/06] A sidewalk connection from the building out to Fairway must be
provided.
Resolved 1 Susan Joy 02/28/2006
23 General [2/28/06] Please provide directional ramps at the northeast corner of Fairway
and the Frontage Road.
Resolved 1 Susan Joy 02/28/2006
24 General [2/28/06] Please provide a sidewalk along the front of the parking stalls
immediately north of the building. Please provide a continuos sidewalk
connection to the building from there and do not offset the sidewalks.
Resolved 1 Susan Joy 02/28/2006
25 General [4/5/06] Label the dimensioned stalls as "typical" if typical and dimension all
atypical stalls. See redlines.
[2/28/06] Please dimension all parking stalls, driveway widths and drive
aisles.
Resolved 1 Susan Joy 02/28/2006
26 General [2/28/06] Please provide a 9' utility easement along Fairway (currently
showing a 6').
Resolved 1 Susan Joy 02/28/2006
3/7/2011 Page 3
Project: 4900 SOUTH COLLEGE AVENUE PDP, CHANGE OF USE - TYPE II
ID Topic Issue Status Round Comment By Initial Date
27 fire [2/28/06] A fire lane is required. This fire lane shall be visible by painting and
signage, and maintained unobstructed. A fire lane plan shall be submitted for
approval prior to installation. The fire lane shall be designated on the plat as
an Emergency Access Easement. The minimum required width shall be 20
feet throughout the length of the fire lane. If a fire lane cannot be provided,
the building shall be fire sprinklered.
Resolved 1 Carie Dann 02/28/2006
28 fire [4/19/06] Our map shows the closest fire hydrant at the southeast corner of
College Avenue and Fairway Lane. Applicant needs to determine this hydrant
meets minimum flow requirement.
[2/28/06] Hydrant spacing and water flow must meet minimum requirements
based on type of occupancy. Spacing and flow requirements for commercial
property are 1,500 gpm at 20 psi residual pressure, spaced not further than
300 feet to the building, on 600-foot centers thereafter.
Resolved 1 Carie Dann 02/28/2006
29 fire [2/28/06] The proposed building exceeds 5,000 square feet for type V
construction and shall be fire contained or fire sprinklered.
Resolved 1 Carie Dann 02/28/2006
30 General [2/28/06] Please show all utilities. Resolved 1 Susan Joy 02/28/2006
31 General [2/28/06] If Transportion Planning is ok with using the existing drive aisle as
the future north south connection, then you will need to dedicate an additional
access easement to the northern property line. Please provide enough of a
design to make sure that the proposed future easement will work in the
future. More internal discussion is necessary to determine the exact scope of
this development's responsibilities.
Resolved 1 Susan Joy 02/28/2006
32 General [2/28/06] Bonnie Ham (Post Office): Developer must provide appropriate
mailboxes for additional deliveries.
Resolved 1 Shelby Joy 02/28/2006
33 General [2/28/06] The 10' trail easement shown on the site plan should not be located
on the property located at 4900 South College, but rather the property directly
to the east.
Active 1 Kurt Ravenschlag 02/28/2006
34 General [2/28/06] A 20' Public Access Easement will be required for auto circulation
from Fairway Ln to the properties to the north per the South College Access
Plan. The easement will need to span from the south property line to the
north property line. The existing drive aisle located on the east side of the
building can be used for this easement.
Active 1 Kurt Ravenschlag 02/28/2006
3/7/2011 Page 4
Project: 4900 SOUTH COLLEGE AVENUE PDP, CHANGE OF USE - TYPE II
ID Topic Issue Status Round Comment By Initial Date
35 General [2/28/06] The existing sidewalk connections from the north parking area
should align or connect with the existing walkways on the east and west sides
of building.
Active 1 Kurt Ravenschlag 02/28/2006
36 General [2/28/06] The sidewalk located along the Frontage Rd. needs to be widened
out to 6'.
Active 1 Kurt Ravenschlag 02/28/2006
37 General [2/28/06] Any sidewalks not located within public ROW should be placed in a
Public Access Easement.
Active 1 Kurt Ravenschlag 02/28/2006
38 Stormwater [4/17/06] The provided water quality outlet detail needs to be revised.
As currently shown, the water quality pond will hold water up to 2 inches deep
before it releases. Please make sure that the plate has an opening at the
invert elevation of the pond.
According to Urban Drainage criteria, rows need to be separated by 4 " in
order to use that manual's charts.
If no utility plans are being submitted, then how will the change to the pond
outlet be documented. Maybe a note on the site plans referencing the
drainage design documents would be appropriate.
[3/1/06] The original detention area did not have a water quality component.
Since the pond is already built and landscaped, no new detention will be
required, however, it is requested that the pond outlet, be modified to include
a water quality plate and detention. A variance will be approved to account
for the water quality volume as being part of the quantity volume.
Please provide water quality calculations.
Active 1 Basil Hamdan 03/01/2006
39 General [3/1/06] Please show all existing features within 150' of the project
boundaries. Most concerned with neighboring driveways (across the street,
next door) and what's exisiting to the north.
Resolved 1 Susan Joy 03/01/2006
40 General [3/1/06] Parking setbacks of 20' or 40' off Fairway apply. Please see Detail
19-6 in LCUASS. Rather than removing a parking stall, you have the option
of striping it out, putting your bike racks in it, etc.
Resolved 1 Susan Joy 03/01/2006
41 General [3/2/06] No issues. Active 1 Doug Moore 03/02/2006
3/7/2011 Page 5
Project: 4900 SOUTH COLLEGE AVENUE PDP, CHANGE OF USE - TYPE II
ID Topic Issue Status Round Comment By Initial Date
42 General [3/2/06] The Transportation Development Review Fee for this project totals
$5655. A check for $2530 has been received therefor, an additional $3125 is
due (.25 cents x 12,500 sf). Please see the attached revised fee calc sheet.
Resolved 1 Susan Joy 03/02/2006
44 General [4/5/06] Please provide handicapped ramps for the handicapped parking
stalls.
Resolved 2 Susan Joy 04/05/2006
45 Easement
Dedications
[6/1/06] Language agreed upon by the attorneys has been altered again.
Please correct the documents to read as shown on the redlines. Also, the
document keeps referring to "roadway" and "street" improvements and this is
incorrect. This is not a street. It is only a driveway through the parking lot
that will eventually have cross access to the north. The city does not and will
not maintain a private parking lot or driveway.
[4/7/06] The 20' access easement dedication was incorrectly submitted and
needs to be resubmitted using the UNALTERED City template. The exhibit
and legals for this easement were checked and accepted. OK to submit
signed and wetstamped docs from the surveyor along with a $250 filing fee
made out to the City of Fort Collins. Larimer County filing fees also apply and
that amount will be calculated once all the paperwork is received.
Active 2 Susan Joy 04/07/2006
46 Easement
Dedications
[4/7/06] Please submit a legal and exhibit for the 5' access easement along
the frontage road for our review and approval. A dedication statement must
also be completed using the UNALTERED city template previously given to
VFRipley. A $250 filing fee applies as well.
Resolved 2 Susan Joy 04/07/2006
47 General [6/1/06] Please remove the rest of the note as you are constructing from this
document. See redlines.
[4/7/06] Remove the note "This is a land use planning document ." No civil
drawings are being submitted so this note is not correct.
Active 2 Susan Joy 04/07/2006
48 General [6/1/06] We have just been given a standard note to be placed on plan sets
that do not list out all of the notes in Appendix E1 and E2. Please replace
what I've previously asked you to note with the attached note. Sorry for the
confusion.
[4/7/06] Add a note: See Appendix E1 and E2 of the Larimer County Urban
Area Standards for other requirements.
Active 2 Susan Joy 04/07/2006
3/7/2011 Page 6
Project: 4900 SOUTH COLLEGE AVENUE PDP, CHANGE OF USE - TYPE II
ID Topic Issue Status Round Comment By Initial Date
49 General [4/17/06] Is any additional lighting proposed? If so, please indicate where
and what type. See lighting standards in LUC Section 3.2.4. If not, please
place a note indicating such on the site plan.
Resolved 2 Shelby Joy 04/17/2006
50 General [4/19/06] From Technical Services: None of the symbols for trees and
shrubs are dark enough to scan to file. See Appendix E6 for scanning
requirements.
Active 2 Susan Joy 04/19/2006
51 General [4/19/06] No further comments. Active 2 Kurt Ravenschlag 04/19/2006
52 General [6/1/06] Please correct all overlapped labeling to meet scannability
requirements.
Active 3 Susan Joy 06/01/2006
53 General [6/6/06] Rick Lee (Building Department): Change of occupancy requires
compliance with current building code (see attachment).
Active 3 Shelby Joy 06/06/2006
54 Landscape Plan [6/6/06] Please modify the note regarding the outlet modifications to say:
See Drainage Design Documents prepared by Northern Engineering for
modifications to the existing detention outlet facilities.
Active 3 Basil Hamdan 06/06/2006
55 fire [4/4/07] . Active 3 Carie Dann 04/04/2007
3/7/2011 Page 7