HomeMy WebLinkAboutGREENBRIAR VILLAGE PUD - 19 93 - CORRESPONDENCE - STAFF'S PROJECT COMMENTS (4)This completes the staff review comments at this time. Additional
comments may be forthcoming as the various departments and
reviewing agencies continue to review this request. Please be aware
of the following dates and deadlines to assure your ability to stay
on schedule for the May 24, 1993 Planning and Zoning Board hearing:
Plan revisions are due May 5, 1993 by 12:00 noon. Please contact me
for the number of folded revisions required for each document.
PMT's, renderings, and 8 folded copies of final revisions (for the
Planning and Zoning Board packets) are due May 17, 1993.
Final documents (including the signed development agreement,
applicable mylars and utility plans) are due May 20, 1993 by 12:00
noon.
Please contact me at 221-6750 if you have questions or concerns
related to these comments. I would like to schedule a meeting with
you as soon as possible, if necessary, to discuss these comments.
S' rely,
t v
Project Planner
xc: Kerrie Ashbeck
Sherry Albertson -Clark
Advance Planning
Stormwater Utility
Transportation
Jeff Laughren
Stewart & Associates
file/Project Planner
access to the parking lots.
14. The City Transportation Division has not completed their
review of this request yet, due to the late submittal (April
15, 1993) of the traffic study. I have not yet received
comments from them but it is possible that it might be
necessary to connect Butch Cassidy Court to Greenbriar Circle
to the east. Questions pertaining to the traffic issues should
be directed to Rita Davis. She can be reached at 221-6608.
15. A copy of the Engineering Department's comments is attached to
this letter. The utility plans as submitted are not adequate
for a combined Preliminary 6 Final review. Staff feels that
this project can move ahead as a Preliminary review only, with
the Preliminary going to the Planning and Zoning Board on May
24, 1993.
16. Planning comments:
a) There is no fencing indicated on the Site Plan or the
Landscape Plan. Fencing is shown on the "Typical Planting
Detail". Will there be perimeter fencing or fencing around the
patios? If so, it should be identified.
b) Will the Garden Areas have access to water connections?
c) The sidewalk should be connected to the existing sidewalk
on the north side of Butch Cassidy Court.
d) Elevations for all four sides of the buildings is needed.
The elevations must identify the proposed height of the
buildings, the materials, colors, etc.
e) What will be the groundcover treatment on the "back" sides
of the buildings? The "Typical Planting Detail" should include
labeling of the plantings and treatment.'%. (t�
f) The Site Plan should identify when the phase with the
clubhouse will be built.
g) The materials and colors for the trash enclosure should be
included on the Site Plan. Also, a detail showing materials
and colors for the gazebo is needed.
h) More information on the berming is needed. Where will they
ba and how tall? 18" high berms will not screen the parking
areas.
i) The parking spaces backing into Butch Cassidy Court are not
recommended. The platting of the property seems strange. Lot
1 is left with essentially no parking and no way to get to the
units from the large parking area.
j) The SITE must be shown and identified on the Vicinity Map.
6. Public Service Company of Colorado states that the developer's
architect had indicated in telephone conversations that there
would be an unobstructed 15' utility easement around the
outside perimeter of this project. The Site and Landscape
Plans indicate that in some cases building envelopes extend to
within 10' of the property boundary and that patios extend
even beyond the building envelopes. Proposed trees will also
obstruct use of this space for multiple utility lines. Front
building setbacks from the rear of the sidewalks fail to meet
the 15' specification required to install both electric and
natural gas facilities behind sidewalks as is normally done.
Installation of electric and/or natural gas lines in paved
areas may be a required option. Utility easements as proposed
on the subdivision plat are inadequate.
7. City Light 8 Power states that the Site Plan shows the
location of a street light on the north side of Butch Cassidy
Court, just east of Building #6. The Landscape Plan shows a
couple of street trees that appear to be too close to the
light. Street trees must be a minimum of 401, horizontally,
from a light pole.
8. The Water/Wastewater Department states that a utility plan
must be submitted to and approved by the City.
9. The Poudre Fire Authority has the following comments:
a) The Phase One parking lot does not provide 20' inside and
40' outside turning radius.
b) Both sides of the Phase One parking lot, at the ends of the
center parking, must be signed "No Parking - Fire Lane"
with approved signs and the curbs painted red. An
unobstructed 20' wide drive lane must be provided.
c) The Phase One parking lot must be included in a public
access easement.
10. A copy of the Stormwater Utility's comments is attached to
this letter. It appears that the drainage information
submitted is not sufficient for a combined Preliminary & Final
review.
11. Parkland fees of $625 per dwelling unit will apply for all
v residential development and be collected at the time of
issuance of building permits.
12. There is an 18' drive width around the island in the cul-de-
sac at the end of Butch Cassidy Court. The City standard is a
c28' width in this situation. The City is discouraging the use
of the center island.
13. Utility easements for this phase do not appear to be adequate,
and the subdivision plat does not provide for any public
16. The O.D.P. indicates a general pattern for drainage. It
appears that someone has thought it through but there is no
narrative or indication of the method of conveyance (i.e.,
ditch, street, pipe, etc.). An overall drainage plan, reviewed
and signed by an engineer, should be submitted. The plan does
not need calculations unless the design engineer thinks there
is reason to check flows to see if what is proposed is really
feasible. Some sub -basin delineations may be needed just to be
able to describe each area and how it is planned to drain.
Please contact Glen Schlueter of the City Stormwater Utility
with questions pertaining to storm drainage. He can be reached
at 221-6589.
17. Blue Spruce Drive should be labeled on the plan.
18. Pedestrian connections should be indicated from Phase 1 to
Greenbriar Circle.
19. The Solar Orientation Ordinance will apply to the Phase 2 -
Single Family/Duplex portion of the development. This must be
addressed with the Preliminary P.U.D. plans.
20. The Engineering Department is suggesting shifting the
alignment of Sundance Circle and the intersection of Sundance
Circle and Greenbriar Circle further to the south, creating
more separation from Willox Lane. What is the circle on
Sundance Circle?
Greenbriar Village P.U.D., First Filing - Preliminary/Final
y1. The plans should represent the fact that this is a P.U.D.
2. The Site Plan, and Building Envelope Plan detail, should
identify that all buildings contain 4 dwelling units each.
w This is unclear with the information provided.
3. Both control monuments shown on the subdivision plat must be
described. All outer boundary monuments must be described.
4. The Residential Uses Density Point Chart submitted on April 5,
1993 is claiming base credit for being within 3,000 feet of a
major employment center and bonus credit for a commitment to
developing low income housing. What is the major employment
center that is being used for credit? This will need to be
substantiated in writing to the City. Your commitment to low
income housing must be presented in the Planning Objectives or
in some other form of writing submitted to the City and
included on the Site Plan.
5. Columbine CableVision would like to work with the developers
in wiring the units in a home -run system. They would also like
to possibly go joint trench up to the buildings with main
lines. Your contact person at CCTV is Dennis Greenwalt.
6. A legend should be added to the O.D.P. indicating, as a
minimum, the significance of the arrows (presumably drainage
patterns) and conceptual pedestrian connections both on- and
off -site.
7. Note 3 should indicate that Any part of an exterior building
wall will be located within 150 feet of an access for fire and
emergency equipment.
8. Note 6 should indicate that all signs will comply to City of
Fort Collins standards and will be restricted to signage as
set forth by the P.U.D. plans. Any intent to change the
approved signage must be submitted to the City Planning
Department for review as an Administrative Change.
9. Note 7 must be eliminated from the plan. This statement is too
open-ended and could potentially create future misconceptions
and misunderstandings about what is allowed to occur on the
property.
10. The SITE for this development proposal must be shown and
identified on the Vicinity Map.
11. The Residential Uses Density Point Chart does not relate to
the O.D.P. It must be attached to the Greenbriar Village
P.U.D., First Filing (and subsequent filings) plan.
12. Public Service Company of Colorado has stated that dedication
of adequate utility easements must be provided by individual
plats (filings).
13. The developer needs to be aware of the City ordinance that
requires the undergrounding of existing overhead utilities
prior to issuance of building permits. In this case, the
ordinance will apply to lots in the southerly part of "Phase
4 - Single Family" and lots adjacent to Redwood Street in
"Phase 2 - Single Family/Duplex". It will also apply to any
development along the south side of Willox Lane. Please
contact Doug Martine of City Light & Power with questions
pertaining to these comments. He can be reached at 221-6700.
14. The City Water/Wastewater Department has stated that a Master
Utility Plan must be submitted and approved prior to the
approval of construction plans for any portion of the
Greenbriar Village P.U.D. Please contact Mark Taylor with
questions pertaining to water and sanitary sewer services. He
can be reached at 221-6681.
15. Timing for construction of Redwood Street and its relationship
to the proposed phasing of this development is critical.
Sufficient secondary points of emergency access for any phase
is required. Please contact Warren Jones of the Poudre Fire
Authority with questions pertaining to emergency access
requirements. He can be reached at 221-6570.
Community Planning and Environmental'Services
Planning Department
City of Fort Collins
April 21, 1993
Ed Zdenek
ZTI Group
1220 South College Avenue
Fort Collins, CO. 80524
Dear Ed,
Staff has reviewed the submittals for the Greenbriar Village P.U.D.
- overall Development Plan and Greenbriar village P.U.D., First
Filing - Preliminary/Final, and would like to offer the following
comments:
Greenbriar Village P.U.D. - O.D.P.
1. The Greenbriar project is being reviewed as a P.U.D. and the
plans should reflect this.
2. The property is in the RP and the RMP zoning districts. The
portion south of the existing Sundance Hills P.U.D., Second
Filing is zoned RMP.
3. It is being recommended that the Development Phasing Plan
schedule submitted as a separate document be added to the
O.D.P. for Greenbriar Village P.U.D.
4. The phase lines are unclear on the O.D.P. Phase 2 is actually
comprised of what area? What is the status/intent/proposed use
of the parcel at the northeast corner of the O.D.P., at the
intersection of Willox Lane and Redwood Street?
5. Submittal requirements for 0.D.P.Is state that the area shown
on the plan must extend beyond the property lines of the
proposal to include a survey of the area within 150 feet of
the proposal and should include:
a) Land uses, location of principal structures and major
existing landscape features;
b) Densities of residential uses;
c) Traffic circulation system;
d) Natural features of the landscape; and
e) General topographical mapping at same scale as the O.D.P.
281 North College Avenue - P.O. Boy W - Fort Collins, CO 80522-0580 - (303) 221-677;0