Loading...
HomeMy WebLinkAboutOAKWOOD SCHOOL NCL SITE PLAN REVIEW - 13 93 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORT, I Projecl: Oakwood School 1401 W. Mouutttin tort Collins, CO S1lC Plan Vic Smith Mounlain Avenue —,. Alley Lt5' - LOT S17..E: Approximmely 20,758 BUILDING SIZE: Approximately 5,952 NOTE: Not to weto. DIUi.ncot stud site anoemmtlis ore npproximeto livid casinos list prunntoed. ,m r au. nn N. o•o,)I �� )•� I0000 Il ri rInVOMN{)) CO(IIICrf N/ rY ...... —'10 9000 rO.YOL. .rfwnlRl.rr 10 Y.rr wr.I rN 8000 NOr TOY 0I CY.NN[C 7000 ) Is .r ar.Daa of c.Os1 SLO11 .08 1.0 6000 .f 1(nI Nf1 11 R N INnf1[Olwn, •S.l. .O7 5000 r.of , 1011.1.0. 1.., - BO o6 4000 -Jo EXAMPLE ISlf ..%.,a Irwe it .05 3000 nrwfN 1 • 0.01 oo -.60 - r0 f • L. n , of .50 2000 Opt Q LL z o LL I INO O In [rs .03 .40 - - O z - -- -- — -. -..._ - -- z 1 N ' 1000 _ , z .30 900 �? eoo T C d .. ... MA600 500 i - r m v .. ' .20 ! O 400 z ' .... ...... w z I INSTRUCTIONS - - J Q 300 �- - - .01 o- OF I co.Nrfl ,in :um +nw it nrr r.I Q n) w - - z .wn c0.ur.r m,uuwcr Inr .rr•I = .008 200 n) p(rrN u, nnv rrn IJ,as w/a1 z rwlr..lfcr .. tD..rwr. r wr .Bw - oz Q - .007 U) .10 cnY.0 .r sow r,n. o, .V 006 LaJ _ a 08 100 s urn c1r.Nwn :..-. W -.07 -90 O 8O •S SIrOYN VS[ NOYOf...rrr w,111 , . - .004 .06 70 LL , 60 a O 50 ) to 01 rC.YIN( O oo3 05 40 oscwuc( D, rw I p �•,.:.."-I r co 04 IORr�nw 01 C11.NN,l 1 I (�I I• � 30 N.YrNO YIDrM f 0(1[NYIM! Of... I ION rOI.L 1-%C... 1.1 •Y 00 [NrIR( S[C1.0" a rN(N VS! 4o.00.... rn !• L .03 20 Of IrNY(1Nr` 0. IN SCfrInN n /nR p, 1iy Q to of tI.YIYr Olirn. RO! I • H r. f,nYln.rrf )cello. I••• .02 10 IDIIOY 1r.VCIro, ' �. 1 � W en. m Io oatuu wDf Iw � .001 p arcrmN R .t .,,I.Fo Of f1. ) on ru. D 11. From BPR ,Lnr1 ,.Irn P. .wp Orrlw ) 11.1. 0, 1. • % Figure 4-1 01 NONOGRAPH FOR FLOW IN TRIANGULAR GUTTERS (From U.S. Uept. of Commerce, Bureau of Public Roads. 1965) MAY 1984 4-3 DESIGN CRITERIA R�t�o I Metlti4 A,,e,, aF 41I41 �o be fav-eA 1 1' x 150' = o h 4 c S = 0. 02 (Z tt.7 Pam- , = I 'SO ay. Slopke-, = 0•609 &*5 a •r+Av i'%zfty�w S2- M.✓\ LIz i 5,4 �t,r '1 1 �x�Sr,� 6rLAvrG(� DP= Iles, Pf' 7711( Ggnv.ve/ _ (�. �� ��= O.S(o• 3Z� = D• t!a c.�s c1 �Z - (C�sp� - e���� �• r5 = �D, 45 )�o.«�) = o.o7c� IF &)o i5rkE a •F La OS Etin-i;,; h. E D TR I= G urrQfZ,) .-F�j+ e A V6 G14 kfJGe, ,A.) Pi-:, p%+ 4rOrZ r.�r, loo - y r. S-r oaAt i f� T-rt�F, Gµ-rrrc2 WOk-O LD lba a (F.oY,. F�5 4 1, Nom-or r �(" •th tr c, 5v44ehs ` ) x5s WIe V1- o, oi'S = l l . S s = o� G8 3� = 0,003S zz/n_ �jo5 ��►t;� l �gorf = o. i5' o, Iq -0.14; * 0, 03,alml TWS is T42,a+ash' e, K&+ coJk ocz aA Northern Engineering Services, Inc. Final Approved Report Date 3�g, 3 March 3, 1993 Mr. Glenn Schleuter Stormwater Utility City of Fort Collins 235 Mathews P.O. Box 580 Fort Collins, Colorado 80522-0580 re: Drainage of Alley, Oakwood School Fort Collins, Colorado Project No. 9311.00 Dear Glenn: Northern Engineering is pleased to submit this Drainage Letter for your review. It represents a study of the existing and proposed runoff characteristics of an alley south of the property located at 1401 W. Mountain Avenue, Fort Collins, Colorado. An existing building would be converted to a private school. The only changes that will effect the drainage of the site are due to the asphalt paving of the alley adjacent to the property. Presently, the alley is paved with gravel and drains east to the gutter on McKinley Street. An inverted crown section (17' wide) would be constructed adjacent to the south property line and match the existing grades at each end. Using the Rational Method to quantify the drainage flows, the only parameter that would change is the runoff coefficient, C. Storm drainage criteria for the city of Fort Collins gives for gravel drives, C? = 0.50, and for asphalt drives, C3 = 0.95, which would cause a 90 percent increase in flow. Since the existing peak runoff from the alley for a 100-year storm is only 0.16 cfs, the new peak runoff would be 0.31 cfs. Translating this into terms of the maximum change in depth of flow in the gutter on McKinley Street, no more than 0.03 feet increase in depth would be expected. If you should have any questions or comments as you review this letter, please feel free to contact me at your earliest convenience. Sincerely, YD-RTHERN ENGINEERING SERVICES, INC. Terr.�Enany 420 S. Howes • Suite 106 • Fort Collins, Colorado 80521 • (303) 221-4158 • Fax (303) 221-4159