Loading...
HomeMy WebLinkAboutORCHARD PLACE PUD PRELIMINARY - 40 93 - CORRESPONDENCE - CORRESPONDENCE-CONCEPTUAL REVIEWU S. Water and sewer mains are available in Orchard Place. If the units are contained within one building, you can run one service into the building and use a master meter. 9. The property is located in the Canal Importation Basin. Stormwater development fees are $6181.00 per acre, subject to the coefficient of run-off. These fees are payable at the time of building permit issuance. 10. A standard submittal should include a drainage and grading plan, storm drainage report, and an erosion control plan. 11. On -site detention will be required. You will have to tie into the existing storm sewer. Your engineer could look into capacity in the R.O.W. for outfall as well. 12. You will be required to submit a set of utility plans. Public improvements, such as sidewalk, curb, gutter, curb cuts, etc. should be shown on the plans and should be to city standards. The developer will be required to enter into a development agreement with the City for public improvements and storm water facilities. 13. Street oversizing fees are $584.00 per unit and are payable at the time of building permit issuance. 14. There may be a repay agreement due for improvements already constructed on Orchard Place. Please contact Matt Baker at 221- 6605. 15. Planning submittal should include a site plan, landscape plan, architectural elevations, point charts, and written planning objectives. Please see attached information from the LDGS for detailed submittal requirements. 16. Staff will be concerned about adequate buffers, both landscaped and fenced,•between the proposal and surrounding existing land uses. The front buffer area between parking and the street should be bermed and planted. CONCEPTUAL REVIEW STAFF COMMENTS MEETING DATE: May 3, 1993 ITEM: 8 multi -family units on a 19,000 square feet undeveloped, unplatted parcel of land located on the north side of Orchard Place, west of Taft Hill Road. APPLICANT: Don Richmond Richmond Associates 420 W. Oak Fort Collins, CO 80521 LAND USE DATA: This is a proposal for 8 multi -family units on 19,000 square feet. Seventeen parking spaces are proposed. Proposed are 6 two bedroom, one three bedroom, and one two bedroom handicapped accessible unit. The units would be two story townhouse type units. COMMENTS: 1. Normal Light and Power development charges apply. Please coordinate with Light and Power for a transformer location. 2. A subdivision plat will be required as part of the Planned Unit Development (PUD) submittal. Easements for existing and proposed utilities,will have to be dedicated. 3. The property is zoned RMP, Medium Density Planned Residential,. and a PUD will be required for the proposed use. 4. Parkland fees of $625.00 per unit are due at the time of building permit issuance. 5. The Fire Authority requires a minimum aisle width of 20' and turning radii of 20' inside and 40' outside. 6. The units must be within 400' of a fire hydrant. Please show, on the site plan, the location of existing or proposed fire hydrants. 7. Transportation requires that a traffic analysis study be submitted with the PUD.application. The study does not have to be a full impact analysis, but should primarily focus on trip generation, and impacts on local streets. The study can be a short memo/letter format. For more information, please contact Eric Bracke at 221-6608. Commk- :ty Planning and Environmental .,ervices Planning Department City of Fort Collins May 7, 1993 Don Richmond Richmond Associates 420 W. Oak Fort Collins, CO 80521` Dear Mr. Richmond:. For your information, attached is a copy of the Staff's comments concerning 8 Multi -Family units at Orchard Place, presented before the Conceptual Review Team on May 3, 1993. The comments are offered informally by Staff to assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 221-6750. Sincerely, Kirsten Whetstone Project Planner KW/gjt Attachments cc: Tom Peterson, Planning Director Kerrie Ashbeck, Civil Engineer Transportation Department Stormwater Department Project Planner File 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6750