Loading...
HomeMy WebLinkAboutRAINTREE TOWNHOMES PUD PRELIMINARY - 42 93 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTS1 � p will- be at level of service B and C. The intersections along Raintree Drive will be at level of service A for all movements. 1 The right-in/right-out access to Shields Street is recommended because it will greatly reduce the "non Senior Center traffic" that 1 will be using the main access due to the access easement which will be provided. The right-in/right-out access to Shields Street will operate acceptably. It is recommended that this access be located on/near the property line between the vacant parcel and the parcel 1 on which the 12 dwelling units are being considered. This location will provide a single point of access while serving two properties. This location is about 300 feet south of Raintree Drive. It is 1 recommended that the right-in/right-out have a right -turn auxiliary lane. Provision of this auxiliary lane will move the west curb of Shields Street about 10 feet to the west. It will likely use the 1 sidewalk area on the bridge that crosses the New Mercer Canal. The sidewalk and bike path can be provided on a separate structure to the west of the existing bridge. 1 A long range analysis was not performed. Peak hour traffic volumes on Shields Street are expected to grow modestly over the next 20 years. Traffic growth on Shields Street will likely occur 1 during the non -peak hours. The signalized Shields/Raintree/Centre intersection will operate acceptably for many years into future. Acceptable operation will occur at the Raintree stop sign 1 controlled intersections with a more than five times increase of the traffic volumes shown in Figure 6. It is not likely that future uses along Raintree Drive will create a five times increase in traffic. 1 III. Conclusions The following summarizes the significant findings as a result 1 of this study: The Fort Collins Senior Center traffic can be accommodated on the area streets. 1 - Current traffic operation at the area intersections is acceptable. 1 - In the short range future (1995) with the Senior Center traffic, the key intersections operate acceptably. 1 - In the short range future (1995) with the traffic from the Senior Center, fast food restaurant, and 12 dwelling units, the key intersections will operate acceptably. ■ - The access easement in the southeast corner of the Senior Center parcel will provide better access to the properties to the 1 4 1 .= y r p ^ WCN � ao = 22/23/14 39/42/25 N M cm N A Go L �zM 37/55/28 INN �34 + �--8 16 it �14/333/35 15130/25 2/5/2 �/ RAINTREE 17/25/16 f r 19/32/21 4/20 15 =i to 0/1 o Z ado N LEGEND AM / NOON / PM N n � Of in c 54 109/136 N C7 10 f_ 2 5 . 7/13/20 51/132/83 CENTRE co to cn 6/34�P34 �N \�� �Mtf7 M O M 1995 PEAK HOUR TRAFFIC WITH SENIOR CENTER, FAST FOOD RESTAURANT AND 12 DWELLING UNITS Figure 6 Table 3 1995 Peak Hour Operation With Senior Center Level of Service Intersection AM Noon PM Shields/Raintree/Centre (signal) 6 Phase B B C Raintree/Shopping Center Access/ Senior Center Access (stop sign) NB LT/T/RT A A A SB LT/T/RT A A A EB LT A A A WB LT A A A Raintree/West Access to Senior Center (stop sign) SB/LT/RT A A A EB LT A A A Table 4 1995 Peak Hour Operation With Senior Center, Fast Food Restaurant, & 12 D.U. Level of Service Intersection AM Noon PM Shields/Raintree/Centre (signal) 6 Phase Raintree/Shopping Center Access/ Senior Center Access (stop sign) NB LT/T/RT SB LT/T/RT EB LT , WB LT Raintree/West Access to Senior Center (stop sign) SB/LT/RT EB LT Shields/Right-in/Right-out (stop sign) EB RT B B C A A A A A A A A A A A A A A A A A A A A B 40 40 development. The roads considered for the operations analysis are Raintree Drive and Shields Street. Background traffic for impacted streets was. projected for 1995 for the Senior Center alone and for the Senior Center with the previously discussed uses that would utilize the Senior Center access. The through traffic on Shields Street was assumed to increase at the rate of three percent to the year 1995. The site generated traffic is added to the background traffic. Trip Distribution Trip distribution was determined based upon an evaluation of trip. productions and the most likely routes available to travel from those productions. The directional distribution of the approaching and departing traffic generated at the Senior Center is a function of: - Geographic location within the City of Fort Collins; - Location of employment/business centers and residential uses which are likely to produce trips; - Access to the site. Figure 4 illustrates the trip distribution percentages used in the subsequent traffic assignments. Traffic Assignment and Intersection Operation Using the vehicular trip generation estimates presented in Table 2, the site generated traffic was assigned to the area street network. The street network consisted of Shields Street and Raintree Drive as they are today. The analyzed intersections were Shields/Raintree/Centre with signalization, and the accesses ' to this site from Raintree Drive. The previously discussed right- in/right-out to Shields Street was also analyzed. Figure 5 shows the short range (1995) peak hour traffic assignment. This assignment also includes the increase in background traffic as described earlier in this report and the traffic generated by the Senior Center. Table 3 shows the peak ■ hour operation at the key intersections. Calculation forms are provided in Appendix D. The signalized Shields/Raintree/Centre intersection will be at level of service B and C during the peak hours. The accesses to Raintree Drive will be at level of service A for all movements. Figure 6 shows the short range (1995) peak hour traffic assignment, which includes background traffic on the area streets, the Senior Center traffic, and the traffic generated by the adjacent uses as discussed earlier. Table 4 shows the peak hour operation at the key intersections. Calculation forms are provided in Appendix E. The Shields/Raintree/Centre signalized intersection 1 3 n Iet-in /Right -out (SHIELDS Assumed as Future Fast Food Restaurant I (Existing Private. I Residence) I I c rn 3 N T L_.J p 1 STREET 4$Z NO SCALE Future Access Easement w W N Z OaC Raintree Shopping Center SITE PLAN Figure 3 ioperation is acceptable and the overall intersection operation is acceptable. Analyses performed for the future conditions assumed a six phase signal. ' III. Proposed Development The Fort Collins Senior Center is proposed on a 5 acre parcel of land west of Shields Street and north of Raintree Drive. A schematic site plan is shown in Figure 3. It is proposed that the main access will be across from the Shopping Center access. A ' secondary access will be located further to the west along Raintree Drive. A third access may be built as the parking area expands to the west. There is an existing private residence and a small vacant parcel east of the proposed Senior Center. While no proposals have been put forth for these properties, it is likely that they will ' be redeveloped as a commercial use. For analysis purposes, it was assumed that these parcels would be combined and have a fast food restaurant. This was considered to be the likely highest intensity ' use for this site. At a meeting involving all the adjacent property owners, it was agreed that an access to this commercial parcel would occur via an access easement through the Senior Center main access to Raintree. Drive. Right-in/right-out access from Shields Street to this parcel was also discussed. The property north of the proposed Senior Center is being considered for development with 12 dwelling units. Access to this property would be via Shields Street. It was suggested in the aforementioned meeting that access to this parcel from Shields Street be shared with the future commercial parcel. This access to Shields Street would be right-in/right-out. Therefore, both of these adjacent properties would have access via the easement to the Senior Center main access. Trip Generation Trip generation estimates for the adjacent uses were obtained from Trip Generation, 5th Edition, ITE. The trip generation for ' the Senior Center was estimated based upon conversations with Fort Collins Senior Center staff. Table 2 shows the trip generation used for the various uses considered in this study. Background Traffic Background traffic is defined as the traffic that is and/or will 'be on the area streets but is not related to the proposed 2 6 L Table 1 1992 Peak Hour Operation Level of Service Intersection AM Noon PM Shields/Raintree/Centre (signal) 4 Phase B B B 6 Phase B B C Raintree/Shopping Center Access (stop sign) NB LT/RT A A A WB LT A A A Table 2 Trip Generation A.M Peak Daily (Noon Peak) P.M. Peak Land Use Trips Trips Trips Trips Trips in out in out Senior Center 700 30 10 20 50 (60) (60) 12 Dwelling Units 120 2 7 8 4 (5) (5) Fast Food - 2.0 KSF 1260 57 34 38 35 (61) (59) ft FORT COLLINS SENIOR CENTER SITE ACCESS STUDY FORT COLLINS, COLORADO OCTOBER 1992 Prepared for: City of Fort Collins 300 LaPorte Avenue Fort Collins, CO 80521 Prepared by: MATTHEW J. DELICH, P.E. 3413 Banyan Avenue Loveland, CO 80538 Phone: 303-669-2061 00 Cl) 0 00 u.i a WN 3 W s I-- July 12, 1993 (File: 9350LT01) o Mr. Mike Herzig Fort Collins Development Engineer o P.O. Box 580 Mo Fort Collins, CO 80522-0580 m Dear Mike: Raintree Townhouses PUD is proposing to build a 28 foot wide public street within the development. According to the Fort Collins Design Criteria and Standards for Streets, this street width will require a variance by the City of Fort Collins. The reasons for requesting/granting this variance are listed ` below: - The street that is proposed to be 28 feet is a cul-de- sac. - The cul-de-sac will access an arterial street (Shields Street). Given the constraints of the subject property, the primary access must be from Shields Street. The access to Shields Street is proposed to be a right- in/right-out with a deceleration lane on Shields Street.' However, it is proposed that there will be alternative access through other properties to the south. - The street will have less than 750 ADT on it. The development itself will have 12 dwelling units, which will generate 120 vehicle trips on an average weekday. The "Fort Collins Senior Center Site Access Study, October 1992, assumed a fast food restaurant on the parcel to south of the Raintree Townhouses PUD. This is likely to be the highest intensity use from a traffic z perspective. This land use will add 470 ADT to the Ui street segment that is just west of Shields Street. z Therefore, the highest traffic volume just west of z Shields Street will be 590 ADT. J - It is proposed that the townhouses would be built on one > side of the street. v Z I recommend that the street in Raintree Townhouses PUD be 28 F feet wide (curb to curb). Given the layout of the Raintree a Townhouses PUD site, I recommend on -street parking be allowed 0 only on one side of the street. Ln If you have any questions or desire additional information, do not hesitate to call me. U LL Sincere1 Matthew J. Delich, P.E. Kral VA,ir`p to Tn,--I^L",I CPS ALL DEVELOPMENT; NUMBERED CRITERIA CHART ALL CRITERIA . APPLICABLE CRITERIA ONLY CRITERION Is the criterion aoplicoole? Will the criterion be sbfisfieb? If no, please explain QO:�`��b' �Q4°�0 Yes No NEIGHBORHOOD COMPATABILITY 1. Social Compatability. . t/ 2. Neighborhood Character 3. Land Use Conflicts 4. Adverse Traffic Impact PLANS AND POLICIES 5. Comprehensive Plan V/ PUBLIC FACILITIES & SAFETY 6. Street Capacity 7. Utility Capacity B h /- b✓2 -43 8. Design Standards cvn / orL 0A 9. Emergency Access _,54r, 10. Security Lighting 11. Water Hazards I/ RESOURCE PROTECTION 12. Soils & Slope Hazard 13. Significant Vegetation 14. Wildlife Habitat 15. Historical Landmark 16. Mineral Deposit 17. Eco-Sensitive Areas 18. Agricultural Lands ENVIRONMENTAL STANDARDS 19. Air Quality 20, Water Quality 21. Noise 22. Glare & Heat 23. Vibrations 24. Exterior Lighting 25. Sewages & Wastes SITE DESIGN 26, Community Organization 27. Site Organization Vol 28. Natural Features 29. Energy Conservation 30.Shadows 31. Solar Access 32. Privacy 33. Coen Space Arrangement 34. Building Height 35. Vehicular Movement ✓ 36. Venicular Design 37. Parxing x/ 38. Active Recreational Areas 39. Pflb'aTe Outdoor Areas ✓ V 40. Pedestrian Convenience v V I 41. Pedestrian Conflicts V 1 1 V 42. Lcnascaoing/Open Areas Vp I I \/ 43. LonoscapingfBuildings \/ I 30e, Cb i C1t+ 44. LandscapingfScreening `/ 1 rr 1, 45. Pudic Access ✓ I 46. $iC❑5 a s Rain+rep, Townl.o�scs f U� DENSITY CHART Maximum Earned Criterion Credit If All Dwelling Units Are Within: Credit a 20% 1 2000 feet of an existing or approved neighborhood snapping center. Vt O zo b 10% 650 feet of an existing transit stop. to C 10% 4000 feet of an existing or approved regional shopping center. d 20% 3500 feet of an existing or reserved neighborhood park community park Of community facility. ^�1 ftor& w lllatColorado. /v W e 10% 1000 feet of a school, meenrg all the requirements of me compulsory education laws of the State ' (J� f 20% 3000feet at a major employment center. ev.+re, 4r Ar J I-ck r zO g 5% 1000 feet of a child care center. h 20% 'North"Fori Collins I 20% the Central Business District. A project whose bounwN is contiguous toexisling urban tlavelopmeni. Credit may be earned as fdksw& 0%—For projects whose property boundary has to 10%configuily j 30% 10 to 15%—For molectswhose oroperty boundary has 10 to 20% contiguity . 15to20%— For projects whose property boundary has 20to30%Contiguity: 30 20 to 25%— For projects whose property boundary has 30 to 40%contiguity, 25 to 30%—For projects whos property boundary has 40 to 50%contiguity. . If it can be demonstrated that the project will redo enon-renewable energy useoge eitherthrough the application of alternative energy k systems or through committed energy conservation measures beyond mat nomlally, required by City Code, a5% bonus may be earned for every 5%reduction in energy use. I Calculate a l% bonus fig every 50 acres inclucie0 in the ofolect. m Calculate the percentage of the total acres in the project that are devoted to recreational use. enter W ofmat percentage as a bonus. If the applicant commits to presenting permanent offsite open space that meets the Citys minimum requirement& calculate the percentage, n of this open space acreage to the total developmentaaeage. enter this percentage as a bonus If pan of the total develooment budget a to be spent on neighborhood pudic transit facilities which are not otherwise required by City Code, O enter 2%bonus for everv$100 per dwelling unit invested. If part of the total development budget is to be spent on neighborhood facilities and services which are not otherwise required by City Code. P enter al%bonus for eVerv$100Der aweningunit mvestea If a commitment is being made to develop a speciffeci percentage of the total number of dwelling Units for low inCOfne families. enter that q percentage at a bonus up to a maximum of 30%. It a commitment is being made to develop a specified oercentoge of the total number of dwelling unitstor Type 'A" and Type'"handicapper Z housing as defined by the City of Fort Collins calculate the bonus as follow& Or Type "A'— Slimes TTaIA�fi LLts iype'B"-1.011mes Type Ir U-1—ts oTTa w In no case shall the combined bonus be greater than 30%. If the site or odlacent properly contains an historic building or place. a bonus may be earned for the following 3% — For preventing or mitigalig outside influences (e.g. environmental land use. aesthetic, economic and=at factors) adverse to its 5 preservation: 3% — FIX assuring that new structures will be in keeoingwim the character of the building or place. whikeavdding total units 3% — FonpropoungowptNeu ofinebuiWirgorpimematwillleoatoriswntinwme.preserwtionandimprovementinan appropnotemonner. If a portion or all of the required parking in the mumble family project is provided underground.within the building. or non elevated parking V=tufe as an accessory use to the primary structure, a bonus may be earned m follows t 9% — For providing 75% or more of the parking in a structure; 6% — Far providing 50-74%of the parking in a structure 3% — For providing 25-49% ofthe parking in a structure. u If a commitment is being made to provide approved automatic fire extinguishing systems for the dwelling wit& enter a bonus of 10%. TOTAL too -30- ACTIVITY: Residential Uses DEFINITION: All residential uses. Uses would include single family attached dwellings, townhomes, duplexes, mobile homes, and multiple family dwellings; group homes; boarding and rooming houses; fraternity and sorority houses; nursing homes; public and private schools; public and non-profit quasi -public rec- reational uses as a principal use;_. uses ,prov,i.ding meeting Irlaces and plaee-s for public assembly with incidental office space; and child care centers. CRITERIA Each of the following applicable criteria must be answered "yes" and implemented within the develop- ment plan. Yes No 1. On a gross acreage basis, is the average residential density in the project at least three (3) dwelling units per acre (calculated for residential portion of the site only)? ❑ 2. DOES THE PROJECT EARN THE MINIMUM PERCENTAGE POINTS AS CALCULATED ON THE FOLLOWING "DENSITY CHART" FOR THE PROPOSED DENSITY OF THE RESI- DENTIAL PROJECT? THE REQUIRED EARNED CREDIT FOR A RESIDENTIAL PROJECT El ❑ SHALL BE BASED ON THE FOLLOWING: 30-40 PERCENTAGE POINTS = 3-4 DWELLING UNITS/ACRE; 40-50 PERCENTAGE POINTS = 4-5 DWELLING UNITS/ACRE; 50-60 PERCENTAGE POINTS = 5-6 DWELLING UNITS/ACRE; 60-70 PERCENTAGE POINTS = 6-7 DWELLING UNITS/ACRE; . 70-80 PERCENTAGE POINTS = 7-8 DWELLING UNITS/ACRE; 80-90 PERCENTAGE POINTS = 8-9 DWELLING UNITS/ACRE; 90-100 PERCENTAGE POINTS = 9-10 DWELLING UNITS/ACRE; 100 OR MORE PERCENTAGE POINTS = 10 OR MORE DUELLING UNITS/ACRE. •,± property is owned by the City of Fort Collins.) 10. There are a lot of animals and critters who use the area between the ditches. It is a corridor of sorts between Spring Creek over by the Centre for Advanced Technology and the open space area at Rolland Moore Park. There are deer, foxes, rabbits, lots of birds, and lots of other animals who use the corridor. I would hate to see this corridor interrupted. 11. Where is the existing road or path located, between the two ditches? If you mean the ditch rider road, there are roads along both ditches, along the south side of the ditch, I believe. We would not be able to disturb those access roads. 12. Have you talked to the ditch company yet? When you do,, could you ask them to clean up the area and ditches more often. No, we haven't talked to them yet, but when we do we will pass along your comments. 13. Would it be possible for the City to incorporate the ditches into the Stormwater System? I don't know about that, but we will be talking to Stormwater about this topic as we prepare our drainage plans. 14. The wildlife in the corridor is a major concern of mine. I've lived in this area for a long time and have enjoyed watching the wildlife in this area. This is a major concern of mine. 15. Where is the nearest Fire Station? Would emergency vehicles have to make a left turn into this site? STAFF: I believe that Station No. 4 at Rossborough is the closest and it is located on Taft Hill Road, south of Drake Road. If this is the case, they would be coming from the south and would have to make a left in. 16. Will the units be rented to students if not seniors. We certainly can not discriminate against students, but the townhouses would be on individual lots, individually owned not rented. If the owner were a senior who chooses to rent to students, we couldn't prevent that. 17. What price range are you looking at? Somewhere around $100,000 per townhouse. 5. G'p, VA 8. What is the access point to the property to the south? What is the reason for it? The City has requested that we provide a possible future access point from our street to allow for internal circulation between the three properties along Shields and Raintree in the event that the other two properties along Shields redevelop and access off of Shields becomes difficult. We don't want that access street or drive going down the back of our property. The City would not be building an access drive. If the properties never develop, then the drive would never be built. The access only provides you the opportunity to gain access to Raintree Drive from your property in the event that.an access drive is agreed to. It doesn't preclude access through the property that is developing. The City will want to combine curb cuts on Shields Street in the future. Wouldn't there be a lot of traffic using the access drive, which looks like it would have to exit through the Senior Center parking lot in order to get to Raintree Drive? We would have to look at the traffic numbers to determine whether this would be a problem. Right now we don't know how the properties on Shields will develop. The traffic from 12 units would not be a problem and it would be mostly the northbound traffic that would use the access drive to avoid the dangerous left hand turn out of the townhouse street. I still think the access drive is a problem, it goes through my property and I don't want it. CITY TRANSPORTATION: The City looks at future access as projects come forward. It is important to look at the big picture and to try to do some future planning to provide a safe and efficient circulation system for the area in the future. The access drive would not be built with this project. 9. How will the area between the ditches be landscaped? We haven't really decided that yet. It may come down to the targeted market. If the occupants are young families or professional couples it might be desirable to put in a more developed, active recreational type landscaping with turf and an irrigation system. If we are looking a seniors, we.may want to leave it more natural. At this time we really don't know. (At the time of this meeting the applicants understood that they owned the property between the ditches, in fact, the J SUMMARY The following are QUESTIONS, CONCERNS, and RESPONSES expressed .at a Neighborhood Meeting for Raintree Townhouses PUD. The applicant is proposing approximately 12 townhouse units on 4 acres, located on the west side of Shields Street, north of Raintree Drive and south of Rolland Moore Park. The property is zoned RP, Planned Residential. Townhouses are not a use -by -right in the RP Zoning District and therefore, the proposal would be reviewed as a Planned Unit Development, and must meet the criteria of the Land Development,Guidance System. MEETING PLACE: Faith Evangelical Free Church MEETING DATE: October 28, 1992 MEETING TIME: 7:00 p.m. CITY PLANNER: Kirsten Whetstone COMMENTS, QUESTIONS, CONCERNS 1. How many stories would the townhouses be? We are thinking that most of the units would be 1 story ranch townhouses, although some units may be 2 stories (maximum of 34' in height). It depends somewhat on our eventual market, we would like to target the senior market with the ranch style units, similar to the Sundering Townhouses. 2. What about parking? Each unit would have an attached 2 car garage with a 2 car driveway. We would provide some additional guest parking in a landscaped area in the center of the cul-de-sac. 3. What about stormwater? Do you have plans yet to show where the water will be directed? We.are not far enough along in the design to have the details of the grading. and drainage plan worked out. We will negotiate with the ditch companies to see if we can release directly into the ditches as one alternative. We will have a stormwater plan prepared prior to submitting the project to the City for review. We can make copies available to you. 4. How are the townhouses oriented relative to the Senior Center? They are north of the Center. The backs of the units would face out towards the park, along the north and west property lines. We have designed the layout so that they wouldn't back to the Senior Center Building. PLANNING & ZONING APPROVAL OWNER'S CERTIFICATION SOLAR ORIENTATION PROJECT STATISTICS PLANT NOTES 6 Yl I�O.p. wwm, aRlnm . ..wr[w ro.�uammga.Yw '.Im.f M�un�"isa M. R�wuuf W a .,wsw r..c��..svav uan PROJECT NOTES .�v �al.]a.I. ro.Yvi Wf ♦�ln/®lO.��la t.�91. M.. w wOI1M...YY.IY.Tumw PLANT KEY o VICINITY MAP PRELIMINARY SIFE dF UNIDSCAPE PLAN LEGAL. DESCRIPTION FILE NO. 959904 PAGE 1 OF 1 RAINTREE TOWNHOMES "EXIBIT A" A TRACT OF LAND SITUATE IN THE SOUIHEAST 1/4 OF SECTION 221 RagNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., AS BEARING SOUTH 00 DEGREES 21 MINUTES FAST AND WITH ALL BEARINGS OONTAINED HEREIN RELATIVE THERETO, BEGIN AT THE SaMMASP CORNER OF THE NORTH 1/2 OF THE SaMMAST 1/4 OF SAID SECTION 22, AND RUN THENCE ALONG THE SOUTH LINE OF SAID NORTH 1/2 OF THE SO(M A.ST 1/4, NORTH 89 DEGREES 53 MINUTES 30 SECONDS WEST 650.20 FEET TO THE SOUIHE RLY BaJNDARY OF THE NEW MERCER DITCH; THENCE ALONG THE SOUTHERLY BOUNDARY OF THE NEW MERCER DITCH, NORTH 34 DEGREES 55 MINUTES FAST 78.58 FEET, AND AGAIN NORTH 52 DEGREES 08 MINUTES 35 SECONDS EAST 263.74 FEAT, AND AGAIN SOUTH 60 DEGREES 20 MINUTES FAST 160.26 FEET, AND AGAIN SOUTH 74 DEGREES 18 MINUTES FAST 119.06 FEET, AND AGAIN NORTH 86 DEGREES 54 MINUTES EAST 142.55 FEET TO A POINT ON THE THE FAST LINE OF SAID SOUTHEAST 1/4; THENCE ALONG SAID EAST LINE SOUTH 00 DEGREES 21 MIWrES EAST 123.70 FEET TO THE POINT OF BEGINNING, EXCEPT THAT PORTION AS CONVEYED TO THE CITY OF FCRT COLLINS, COLa:ADO BY GRANT DEED RECORDED JANUARY 10, 1975 IN BOOK 1630 AT PAGE 972, AND. MORE PARTICULARLY DESCIBED AS FOLLOWS: A TRACE OF LAND SITUATE IN THE SOUIHEAST QUARTER OF SECTION 221 TUQNSHIP 7 NORTHr RANGE 69 WEST OF THE 6TH P.M., IN THE CITY OF FCRr COLLI2ZSI COUNTY OF LARIMER, STATE OF COLORADO, WHICH OONSIDERI2, THE EAST LINE OF THE SOCTTHEFST 1/4 OF SAID SECTION 22, AS BEARING SOUTH 00 DEGREES 21 MINUTES FAST AND WITH ALL BEARINGS OONTAINED HEREIN RELATIVE THERETO, IS CONTAINED WITHIN THE BOUTIDARY LINES WHICH BEGIN AT THE SOUTHEAST OOL0ER OF THE NORM 1/2 OF THE SOUTHEAST 1/4 OF SAID SECTION 22r AMID RUN THENCE ALCM THE SOUTH LINE OF SAID NORTH 1/2 OF THE SOUTHEAST 1/4, NORTH 89 DENS 53 M 2UTE5 30 SECONDS WEST 50.00 FEET; THENCE NORTH 00 DEGREES 21 MINUTES WEST 123.95 FEET; THENCE NORTH 86 DEGREES 54 MINUTES FAST 50.00 FEET TO A POINT ON THE EAST LINE OF SAID SECTION 22; THENCE A 43 SAID FAST LINE, SOUTH 00 DEGREES 21 MIN(TI1'S FAST 123.70 FEET TO THE POINT OF BEGINNING. 0 �~ / �'Qon +o�dDr, nfie ld fir. INirrormere Sundering Qr. Cir. Gilgalad CRd. 0'6� _ .' w gh�te Ct. Chetwood Or. o County �a��� ' c f J w��Aa°c � o 3 Mee .. j N 1 Worthin9fop -pitch Dr.� New of Pie. av Germantowr) Ord > �' Or Centre )Po�ntrea � a et�y .a i U co D Q W. ra a Rd. HavenCr Lno Ct. Glen tr 9a wheel rn Or. iastin s D d c �c avidsun inchester r-'♦ Dr, r fl C o�c �u O ��, Q4,Racky I a. Dr G f= � 3 0 5 ca - a GO z 0 u St.cors FF-: Mountain •: j h °°, a°iv ~°' Swallow J c j u c o rontle� c �w Ct.E `4i W. Rd. w > o - 0 Q V .4.; Q E-cc I U D: ca Sioux Blvd. > y s o` Iu nt ° o Nee Perce y a o °° CIO 047 3 t. a`„n cn ��r° 0 °g Grand 3 -` in14" .��° y, °': ITEM: RAINTREE TOWNHOMES PUD-Prelim. North NUMBER: 42=93 Raintree Townhouses PUD, Preliminary #42-93 August 30, 1993 P & Z Meeting Page 5 1. That additional shrubs and trees be provided between the masonry wall and Lot 1, to enhance the sound barrier. 2. That the design of the pork chop at the intersection with Shields Street be approved by the City Engineering and Transportation Departments prior to final. 3. That off -site drainage easements be obtained and approved by the City Parks and Recreation Department and the City Stormwater Utility prior to final approval. Raintree Townhouses PUD, Preliminary #42-93 August 30, 1993 P & Z Meeting Page 4 two canals (the preference being to leave it in a natural state), architecture of proposed buildings (that it blend with the Senior Center), and safety issues concerning the proposed entrance off of Shields Street (addressed in the "Transportation" section of this report). 5. Transportation All lots within this subdivision will gain access from a local street, Evenstar Court. A "pork chop" at the intersection with Shields Street will restrict access and egress to right turns only. There are safety issues with the hill on Shields Street, with the two canal bridges/culverts, and with existing street trees. A decel lane will be constructed or striped for this project. Staff recommends a condition that the design of the pork chop at the intersection with Shields Street and be approved by the City Engineering and Transportation Departments prior to final. Any street trees which are in the proposed travel lanes, will be relocated, if possible. Additional street trees will also be planted. At some time in the future, when properties to the south redevelop, a possible connection to Raintree Drive and the signalized intersection with Shields Street, will be constructed. The Senior Center PUD has dedicated part of this access easement on that subdivision plat.. The current Raintree Townhouses proposal does not exclude the future access from occurring. Transportation has reviewed the project and does not have concerns with the preliminary plans, at this time. 6. Storm Drainage The Stormwater Utility has reviewed the preliminary plans and is recommending a condition that off -site drainage easements be obtained and approved by the City Parks and Recreation Department and the City Stormwater utility prior to final approval. RECOMMENDATION: The proposed density is supported by the Residential Density Chart. The project meets the applicable All Development Criteria of the LDGS. The proposal is in compliance with the solar orientation ordinance. Staff finds the land use and design to be compatible with the surrounding land uses. Therefore, staff recommends approval of Raintree Townhouses PUD Preliminary- #42-93, with the following conditions: Raintree Townhouses PUD, Preliminary #42-93 August 30, 1993 P & Z Meeting Page 3 The maximum building height will be 27 feet. The buildings will be frame construction with earth tone, hardboard siding with brick and a stone cap to be compatible with the Senior Center. Additional architectural details will be provided at the time of final approval. The roofing will be wood shingles. The product is similar to the Sundering PUD townhomes constructed to the north and east of this site. All units have a two car garage and driveways wide enough to accommodate two cars. All driveways will be at least 20' long, with the exception of Lot.7, which will be 181. Additional guest parking will be available in a landscaped area located at the end of the cul-de-sac. The.developer will provide each unit with a concrete rear patio and will install an 8' section of 6' high cedar fencing between each unit for privacy. The rest of the lots and open spaces will not be fenced. .All landscaping is to be installed by the developer and will be maintained by the Homeowner's Association, including the landscaping in the. street right-of-way. Buffering along the north property line, between the Rolland Moore Park property and the proposed townhouses, has been enhanced with additional landscaping of trees and shrubs. The area between the two canals, which was platted with the Rolland Moore Park plat and which is owned by the City of Fort Collins, will remain in its natural state. This area provides an additional buffer of 90 to 150 feet. The unit closest to Shields Street will have a 26' side yard setback from the flowline. A masonry wall, in materials to blend with the Senior Center, evergreen trees and shrubs, and street trees will provide visual screening and a barrier to decrease the sound of traffic on Shields. Staff is recommending a condition that additional shrubs and trees be provided between the masonry wall and Lot 1, to enhance the sound barrier. Pedestrian circulation is accommodated throughout the site on a sidewalk system, a paved connection to the Senior Center, and via open space tracts between buildings. A pedestrian connection to Rolland Moore Park is accommodated on the sidewalk system along Shields Street, where the 2 canal crossings already are in place. 4. Neighborhood Compatibility A neighborhood meeting was held for this project on October 28, 1992 in conjunction with the Fort Collins Senior Center proposal. Items of concern,were the use of the open space area between the Raintree Townhouses PUD, Preliminary #42-93 August 30, 1993 P & Z Meeting Page 2 COMMENTS: 1. Background The surrounding zoning and land uses are as follows: N:) R-L; Rolland Moore Park, New Mercer Canal, and Larimer County No 2 Canal, S: r-m-p; Proposed Fort Collins Senior Center PUD, Raintree PUD (Raintree Village Shopping Center), and R-L; existing single family home, E: i-p; Centre for Advanced Technology, W: R-L; Rolland Moore Park. The property was annexed in 1970 with the Southwest Annexation. There have been no previous development plans for this parcel. The property is currently vacant and unplatted. This is an infill development project. 2. Land Use The proposed land use consists of 12 duplex units on 1.93 acres. The proposed density of 6.22 DU/ac is supported by a score of 100% on the Residential Density Chart of the Land Development Guidance System. Points were awarded for proximity to a community park (Rolland -Moore Park), a neighborhood shopping center (Raintree Village Shopping Center), a transit stop (Shields and Raintree), an employment center (Centre for Advanced Technology), and for contiguity to existing urban development (Raintree PUD, Centre for Advanced Technology PUD, and Senior Center PUD). The proposed project meets applicable criteria of the All Development Chart of the LDGS. Ten of the 12 lots meet the definition of a solar oriented lot; therefore the proposal is in compliance with the Solar Orientation Ordinance with 83% of the lots meeting the requirements. 3. Design The site plan consists of 6 one and two-story duplex buildings for a total of 12 townhouses. Each unit will have two bedrooms, a two car garage, and private patios. Each unit will be situated on an individually owned lot. Most of the buildings are oriented to take advantage of the southern exposure. All units take access from a local street, which is being designed and constructed to City standards as a 28' local street. This width is acceptable, as only one side of the street will have dwelling units. ITEM NO. 17 MEETING DATE 8/ 3 0/ 9 3 STAFF Kirsten Whetstone PLANNING AND ZONING BOARD STAFF REPORT PROJECT: Raintree Townhouses PUD, Preliminary #42-93 APPLICANT: John McCoy c/o Jim Sell Design 117 E. Mountain Ave. Fort Collins, CO 80524 OWNER: John McCoy 3665 JFK Parkway Building 1 Fort Collins, CO 80525 PROJECT DESCRIPTION: A request for 12 duplex lots for 12 townhouses on 1.93 acres, located on the west side of South Shields Street, south of Rolland Moore Park and north of the proposed Fort Collins Senior Center. The property is zoned R-P, Planned Residential. RECOMMENDATION: Approval with conditions EXECUTIVE SUMMARY: This project consists of a request for 12 duplex lots for 12 units on 1.93 acres of unplatted, vacant property. The units will be one and two stories, with a maximum building height of 271. The units will have 2 car garages, driveways for 2 additional cars, private patios, and open space areas between duplexes. Additional guest parking will be available in a landscaped parking area in the cul- de-sac bulb. The site is located on the west side of South Shields Street, south of Rolland Moore Park and north of the proposed Senior Center. The proposed PUD meets applicable criteria of the All Development Point Chart of the Land Development Guidance System LDGS . The proposed density of 6.22 dwelling units per acre (DU/ac) is supported by a score of 100% on the Residential Density Chart. The proposed plans are in compliance with the solar orientation ordinance with 10 of the 12 lots (83%) meeting the definition of a solar oriented lot. Conditions regarding landscaping, design of the "pork chop", and off -site drainage easements are being recommended by Staff. COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box 580 For[ Collins, CO 80522-0580 (303) 221-6750 PLANNING DEPARTMENT N N DENSITY CHART Maximum Earned Criterion Credit If Al Dwelling Units Are Within: Credit 20% 11 2000 feet of an existing or approved neigrborhood shopping Center .'Ro"k �OKn/ a 1 11 b 10% 650feet ofanearsungtransit shop. IO C 10% 4000 fee' of an existing or oppovedregional snapping centet. Wd 20% 3500fearofanexistingorreservedneighborhoodparkcommunityparkacommunitylacility. QM e 10% 1000 feet of a school, meeting all thefequiremenry ts of the compul5oedacatiOn OW110(theState Of Colorado. W f 20% 3000fee of a motor employment center. C4NkTYC dv.T A.t&'a 0 n 20 g 55% 1000 feel of a child care center. h 20% "North"FLACblllm. I 20% The Central Business District �(1' �{/11pye wIf ° Apotect which has alledst l/6 of its poPeM boundary contiguousto existing sjnbatdevelopmenl. 30 itcan be demonstrated In of me project will reduce non-renewable energy useage either thraupn the application of allernotive energy me oasures rm beyond that hodN required 3 City Code.a 5% bones mov be earned it systems a through committed energy coreva ertin for every, 5% reduction in erergy use. ' I Calculate a l% bonus for every 50 acres included in the Project. m Calculate the percentagedfthe total aces In MG PfOlea MWore devoted to recreational use. enter V2 of tttW pefcenloge dt a bona n 0 the applicant commits to pesen ingpermanent offsfte open space that meets the Cltys minimum requirements colcuksle the percentage of this open space acreage to Me total devebpnehtacfeoge. enter mis percentage as a bonus. If Part of the total development budget is to be spent on neighborhood public honslt facllMeswhich ore hotothetwlse required by ON Code. O enter 2%bonus lot every$100 per dwelling unit invested. If part of the total developrent budget Is to be spent on neighborhood focllllle5 and ser iceswhich we not otherwise required by City Code. rj enter al% bonus lot every S100 per dwelling unit Invested Ba commitment is being nude 10devebp o SPealBegpercentage of the total number ofdwelling uNh fa lowmcome tamllles. enter that 30%. C1 percentoge,as0 bonus. up ro a marenum of If a commitment is being hustle to develop0 speclfled percentage of the total number atdw+elling unth fa Type Wand Type Whtandloapp5d Z housing as defined by me City Of Fort Collins calculate the bonuf mtollow5: O r Typew— .5hmes Type 'A"unih Toot iuTn7ts - (W Type"B"—tOhmes Type i units m ho cow shall the combined bonus be greater than 30%. If the site or adjacent property contains an historic building or place, a bonus may be earned for the following 3% — Fa preventing or mitigating outside influences (e g. environmental land sue, desmerlt. economic and soclal factors) Verse to Its S preservation. 3% — For assuung that new structures will be in keeping with the ChalOCter of the building a place, while avoiding total units 3% — For proposing oduptive uw of the building or place that will lead to its continuance. pretervatlonand lmplovemenr in an appropriate reanner. If a portion or all of the required parking in me multiple family project is provided underground within me looming. or In an elevated parking stfeCiureosor� ' easory use to lhn pot, -Fystructure. a bonus may be earned aS fOlk>\v5. t 9% ... Forprc 6% - Fapoviding5074% of the POningina structure; 3% — For providing 2549% of the parking in a structure. u If a commitment is being made to Provide approved automatic lire extinguishing systems for the dwelling units enter a bonus Of 10%. TOTAL ►od -30- ACTIVITY DEFINITION: Residential Uses 0 All residential uses. Uses would include single family attached dwellings, townhomes, duplexes, mobile homes, and multiple family dwellings; group homes; boarding and rooming houses; fraternity and sorority houses; nursing homes; public and private schools; public and non-profit quasi -public recreational uses as a principal use; uses providing meeting places and places for public assembly with inciden- tal office space; and child-care centers. CRITERIA Each of the following applicable criteria must be answered "yes" and implemented within the development plan. Yes No 1. On a gross acreage basis, is the average resi- dential density in the project at least three (3) dwelling units per acre (calculated,for residential portion of the site only)? 2. DOES THE PROJECT SCORE A COMBINED TOTAL OF 100 PERCENTAGE POINTS OR MORE AS CALCULATED IN THE "DENSITY CHART" THAT FOLLOWS? -29- %)AAfeeTot.-M ko USA, s L-- ALL DEVELOPMENT; NUMBERED CRITERIA CHART ALL CRITERIA APPLICABLE CRITERIA ONLY WII the criterion Is the criterion applicable? Fx; saLshed� CRITERION °�;� Yes Na If no, please explain pe„�' Na,�a�°db NEIGHBORHOOD COMPATABILITY 1. Social Compatibility i 3y 2. Neighborhood Character / & 3. Land Use Conflicts 4, Adverse Traffic Impact g PLANS AND POLICIES 5. Comprehensive Plan PUBLIC FACILITIES & SAFETY 6. Street Capacity 7. Utility Capacity 8. Design Standards QIIQi a r i 9. Emergency Access i / 10. Security Lighting / 11 Water Hazards yA6:: RESOURCE PROTECTION 12. Soils & Slope Hazard 13. Significant vegetation i 14. Wildlife Habitat 15. Historical Landmark 16. Mineral Deposit` 17. Eco-Sensitive Areas 18, Agricultural Lands ENVIRONMENTAL STANDARDS 19. Air Quality /1►i 20. Water Quality Aww '. 21. Noise 22. Glare & Heat 9 `k . 23. Vibrations i t fir, 24. Exterior Lighting 25. Sewage & Wastes SITE DESIGN 26. Community Organization / 27. Site Organization 28. Natural Features 29. Energy Conservation .� . ea 30. Privacy 31. Open Space Arrangement A�. u, i 32. Building Height 33. Vehicular MovementjtAzt i S 34. Vehicular Design 35. Parking i 36. Active Recreational Areas 37. Private Outdoor Areas 38. Pedestrian Convenience 39. Pedestrian Conflicts N w i 40. Landscaping/Open Areas i 41. Landscaping/Buildings r> i 42. Landscaping/Screening r•. 43. Public Access i 44. Signs -12- Land Use Policies Land -use policies achieved by the proposed development include: - Policy 12-- density of at least 3 units per acre. - Policy 22-- contiguous to existing development. - Policy 46-- energy conservation through solar orientation. - Policy 80-- development has access to neighborhood center Raintree Shopping Center); is close to community park (Rolland Moore); water and sewer service are existing; easy access to employment (Centre for Advanced Technology and Raintree Village); development is on the Transfort route; alternative transportation is available by the bike route through the park. Thank you for your consideration, and we look forward to your com- ments. Sincerely, JIM SELL DESIGN,INC. K,j ` cl Kay Force ■ Planning and Zoning Board Members Planning Department City of Fort Collins RE: Raintree Townhouses PUD Planning Objectives . Dear Board Members: Raintree Townhouses is a 2 acre planned residential. development of 12 units. It is bordered by Raintree Shopping Center, Fort Collins Senior Center and Rolland Moore Park. This project is an excellent example of "infill" planning. The proposed senior market will be very compatible with the new senior center and both shopping and recreation are within walking distance,with Raintree Plaza to the south,and Roland Moore Park to the north. The site offers dramatic views of the foothills over Rolland Moore Park. Access & Circulation Access and circulation consists of a cul-de-sac off of Shields Street. Additional parking will be provided in the landscaped turn -around. Pedestrian access to Rolland Moore Park will be provided by paths to bridges.over the New Mercer Ditch and the. Larimer County Canal #2. Land Use .The lots in Raintree Townhouses are zero lot line of approximately 365.0 S.F. The target market is seniors. There .is access between the units to the Open Space adjoining the,Park. 1 SculleSiSr'; biW' _ F.- I��i I■j■ �■ovI ia�ill��li!5��■�,=anm�u I I= - MEAN EIEVATMNi LEFT EIEVATgN _ FNONT E VAT W T E AMN UNIT A � 'CI ■■ MI MI I�I - - g �_ _i_ IL'll'II7Ii�lllll CIIII17IlIl IIIOIIIItlIAllll - I.6. NEW E AMN IEFT E VAI F T E AT 10G11T ELEVATgN ve•. fo• �- UNIT B