HomeMy WebLinkAboutEAST DRAKE TERRACE OFFICE PARK PUD - 58 93 - CORRESPONDENCE - RESPONSE TO STAFF REVIEW COMMENTS12. We understand that a replat will be required if building envelopes have to change. 13. The Governor's Park building setback at the narrowest point is approximately 15 feet from building face to property line. We believe that the trash receptacles function best where they are located. We have added additional screening to insure that they are not seen from Drake Road. 14. We have noted on the landscape plan that landscaping along Drake Road and Stover Street will be maintained by a Building Owner's Association. 15. The gross acreage of the property is 2.18 acres as indicated. Using gross acreage we could gain 6 additional points on Point Chart E, bring our percentage total to 72%. We have use Governor's Park to gain points for joint parking. The question (f) asked if there is direct vehicular and pedestrian access between on -site and off -site parking areas. The answer is yes. If you have any questions regarding the revisions or these comments, please call. Sincerely, RIPLEY ASSOCIATES Linda Ripley cc: Gordon Murdoff Mike Jones, Northern Engineering Services October 6, 1993 Mr. Steve Olt Project Planner Planning Department 281 North College Avenue Fort Collins, CO 80524 Re: Response to staff comments - Dear Steve: East Drake Terrace Office Park Preliminary P.U.D. Tract A will be dedicated as a "utility easement" on the final plat. See note 3 on the landscape plan regarding "no trees within 4" of gas lines" 2. Tract A is intended to serve as a blanket utility easement. 3. Existing and proposed utilities are shown on the utility plan for this project. If they need to be shown on the preliminary plat too, please let us know. 4. Access aisles have been provided for handicap parking spaces. 5. Northern Engineering has received Water/Wastewater comments. They will be in contact with Mike Herzig regarding engineering revisions. 6. A note has been added to the site plan stating that the curbs opposite the perpendicular parking bays on the east -west driveway will be signed "No Parking - Fire Lane" with approved signs and the curb painted red. 7. Northern Engineering field checked the location of the median and believe the location indicated on our drawings is correct. Please let us know if you believe it is necessary to survey the exact location. 8. Northern Engineering has received Stormwater comments and will be addressing that departments concerns at final. 9. The architectural Des4m Guidelines and Standards noted on the site plan were written to achieve similar architectural character. Please let us know if you have specific comments regarding the design guidelines and standards. 10. The developer of each building will be responsible for the development of the courtyard or portion thereof, as well as foundation plantings, and courtyard landscaping. The developer will be responsible for installation of perimeter landscaping and landscaping of the parking lot. 11. We are proposing that individual building plans be reviewed by staff at Final. All information normally required for Final approval would be submitted, including detailed elevations and landscape plans. We are suggesting that individual building plans are not reviewed by the Planning and Zoning Board unless staff believes they are not in conformance with the Preliminary Plan. Our intent is to streamline the review process, since there may be as many as seven separate final plans for this 2- acre site. Please call me, so that we can discuss what kind of Final approval process makes the most sense. RIPLEY ASSOCIATES Landscape Architecture Urban Design Planning 117 East Mountain Avenue Suite 200A Fort Qllllns, Q,lorado 80524 PHONE (303) 224.5828 FAX (303) 48+2443