HomeMy WebLinkAboutPHELPS TOINTON MINOR SUBDIVISION AND IL SITE PLAN REVIEW - 47 93 - SUBMITTAL DOCUMENTS - ROUND 1 - GEOTECHNICAL (SOILS) REPORTLOG OF BORING NO. 5 Page 1 of 1 CLIENT ARCHITECT/ENGINEER Phel Tointon SITE Lots 12, 13, 18, & 19 N. Lemay Subdivision PROJECT Fort Collins Colorado Proposed Building SAMPLES TESTS o I, 0 ': o w in W HI=— CD W Ha H DESCRIPTION N Cr W Z\ z z = S I- Cn In W no O t N 3 F M O Zz ow =IN-J WHO. O. Q O- U E O- L) F- O H >- LL. C) O: LL. ♦- E \ W Approx. Surface Elev.: 93.0 fL C3 z I}- it WCO E oa =(nO_ Cam- 0.5 6" TOPSOIL 92,5 SC 1 SS 12" 3 117.3 26/16/10 STT.TY CLAYEY SAND SC 2 SS 120 5 Brown, moist, medium PA 3.0 90.0 4 SS 12" 25 13.9 PA e CTTTY SAND_ WITH_ = = GRAVEL AND COBBLES 1r Brown/red, moist to wet 5 +� Medium dense to dense .e. _ SW 5 SS 10" 0/10" 15.4 SM PA 10 s SW 6 SS 12" 36 9.2 i. 15.0 78.0 15 SM BOTTOM OF BORING THE STRATIFICATION LINES REPRESENT THE APPROXIMATE BOUNDARY LINES BETWEEN SOIL AND ROCK TYPES: IN -SITU, THE TRANSITION MAY BE GRADUAL. WATER LEVEL OBSERVATIONS Empire Laboratories Incorporated Division of Tetracon BORING STARTED 6-11-93 WL• g 4.4' W D = 4.4' A.B. BORING COMPLETED 6-11-93 WL RIG CME-55 FOREMAN DL �- Checked 4 days A.B. APPROVED NRS JOB # 20935151 71 17 1 LOG OF BORING NO. 4 e 10" CLIENT ARCHMMENGINEER Phelps Tointon SrrF Lots 12, 13, 18, & 19 N. Lamy Subdivision PROJECT' Fort Collins, Colorado Proposed Building SAMPLES TES! X >- C3 _j 0 I LL r_ w in z X DESCRIPTION >. 0: Z\ M z H�_ a.U) X M M W W > I M Z) W 0 LL. CD zz a. C I.- (L M L) 0 r_ W Q. 0 L) 1­0 H >-LL 0 W L)MLL 0: 0 Approx. Surface Elev.: 93.5 ft. W C3 (n :3 M z >- W 0: (L_j Cn to 0 r_ Q:U OCL Z�_Cn Mcna. A^A^A' A A A 0.5 6"TOPSOIL 93.0 PA: SANDY TIAN CLAY CL I ST 12" 15.3 105 4530 Tan/brown, moist, medium to soft CL 2 SS 12" 4 20.8 PA 4.0 89.5 SILTY SAND WITH GRAVEI. 5 Brown/red, moist to wet, dense 6.5 87.0 Cobbles below 6.5 ft. SW 3 SS 12" 27 17.0 SM PA Aw 10— SW 4 SS 12" 32 11.1 Aw 15.0 78.5 15— sm BOTTOM OF BORING THE STRATIFICATION LINES REPRESENT THE APPROXIMATE BOUNDARY LINES BETWEEN SOIL AND ROCK TYPES: IN -SITU, THE TRANSITION MAY BE GRADUAL. WATER LEVEL OBSERVATIONS BORING STARTED 6-11-93 Empire Laboratories Incorporated WL 31 4.89 W.D. 4X A.B. BORING COMPLETED 6-11-93 VIL R10 CMEE-55 FORE -WAN DL Division of Teffacon WL Checked 4 days A.B. APPROVED NRS JOB # 20935151 LOG OF BORING NO. 3 e 1 of 1 CLIENT ARCHITEMENGINEER Phelps Tointon SITE Lots 12, 13, 18, & 19 N. Lamy Subdivision PROJECT Fort Collins Colorado Proposed Building SAMPLES TESTS F- ►}- c 0 J z H DESCRIPTION } co W z W Z\ 7 Z W H H LL CD S O>ti o a- W U W E O d Y U W h0 D-J H O W_L) COJXIL ZF_w W Approx. Surface Elev.: 94.4 fL c o Z F- o: co CO IE oa ovaa ^ ^ ^ 0.5 6" TOPSOIL 93.9 PA SILTY CLAYEY SAND SC 1 ST 12" 17.0 Ill 2020 Brown, moist, soft to medium SC 2 SS 12" 2 18.3 3.5 90.9 PA STT n SAND WITH GRAVEL. Brown/red, moist to wet = 89.4 5.0 Medium to dense IZ 5 Cobbles below 5 ft. SW 3 SS 12" 29 10.8 SM PA ►► 10 r SW 4 SS 12" 34 15.4 + 15.0 79.4 15 SM BOTTOM OF BORING THE STRATIFICATION LINES REPRESENT THE APPROXIMATE BOUNDARY LINES BETWEEN SOIL AND ROCK TYPES: IN -SITU, THE TRANSITION MAY BE GRADUAL. WATER LEVEL OBSERVATIONS Empire Laboratories incorporated Division of Terrscon BORING STARTED 6-11-93 WL g 5.21 W.D. Z 4.71 A.B. BORING COMPLETED 6-11-93 WL RIG CME-55 FOREMAN DL wl Checked 4 days A.B. APPROVED pIRS JOB p 20935151 LOG OF BORING NO. 2 Page 1 of 1 CLIENT ARCHITECT/ENGINEER Phelps Tointon SITE Lots 12, 130 18, & 19 N. Lemay Subdivision PROJECT Fort Collins Colorado Proposed Building SAMPLES TESTS f- o 0to ., o J LL W W z H� U DESCRIPTION } fA 0: W z\ 7 W U.C7 2 o. a. W UEd W 7 >. U W F—O n-J H O >-W CU UCL 2HU7 CD Approx. Surface Elev.: 94.6 ft. c M z 1.- D: Uian IL oD- :3 0a ^ ^ " 0.5 6" TOPSOIL. 94.1 1 ISS 12" 8 10.6 CLAYEY SAND SC 2 SS 12" 7 Brown, moist, medium PA SC 3 ST 12" 14.3 116 1430 SC 4 SS 12" 2 15.8 5.0 = 89.6 5 PA Q GRAVEL. SILTY SAND WITH Brown/red, moist to wet, dense 7.0 87 6 Cobbles below 7 ft. SW 5 SS 12" 30 9.9 t SM PA # 10 SW 6 SS 12" 43 9.0 � 15.0 79.6 SM15 BOTTOM OF BORING THE STRATIFICATION LINES REPRESENT THE APPROXIMATE BOUNDARY LINES BETWEEN SOIL AND ROCK TYPES: IN -SITU, THE TRANSITION MAY BE GRADUAL. WATER LEVEL OBSERVATIONS Empire Laboratories Incorporated BORING STARTED 6-11-93 WL s_ 5.89 W.D. = 4.89 A.B. BORING COMPLETED 6-11-93 RIG CW-55 FOREMAN DL WL Division of Tecracon w'I Checked 4 days A.B. APPROVED NRS JOB 0 20935151 LOG OF BORING NO. 1 Page 1 of 1 CLIENT I ARCH1TECf/ENCINEER Phel Tointon sTPE Lots 12, 13, 18, & 19 N. Lemay Subdivision PROJECT Fort Collins Colorado Proposed Building SAMPLES TESTS r o .. o 0 z H DESCRIPTION } N � zLL z z Hz_ _ = H 0 W m W � O I fA 3 F tl1 O z z ow _i cn J fA 4. d U L (L L) F-O H >LL UMU. WWLL � Approx. Surface Elev.: 95.2 ft. O 7 z )- 11 0: Nm E On. =WO_ (3Add " A A " " 0.5 6" TOPSOIL 94.7 PA SILTY C T _AYRY SAND Brown, moist, medium to stiff 35 SC 1 ST 12" 12.4 116 1660 3.5 91.7 SW SM 2 SS 12" 11 7.5 SILTY SAND WITH GRAVEL PA Brown/red, moist to wet = Medium to dense Y 5 6.0 89.2 Cobbles below 6 ft. SW 3 SS 12" 32 r' SM 117.91 PA i. 10 t SW 4 SS 12" 35 9.1 � 15.0 80.2 15 SM BOTTOM OF BORING THE STRATIFICATION LINES REPRESENT THE APPROXIMATE BOUNDARY LINES BETWEEN SOIL AND ROCK TYPES: IN -SITU, THE TRANSITION MAY BE GRADUAL. WATER LEVEL OBSERVATIONS Laboratories EmpireIN Incorporated BORING STARTED 6-11-93 WL s 5.31 W.D. = 4.89 A.B. BORING COMPLETED 6-11-93 RIG CME-55 FOREMAN DL WL Division of Tertacon WL 4 days A.B. APPROVED NRSJOB k 20935151Checked _,,.__ Ta, l-&' Oaf'T►� Buhl�>-' 13a1-T vP F I Kr- H-(pRAt4-i liL ✓VAT 1.00 : I ov. o PR�P&pt�POn t!IU I Lplhlfa - efig J : I ft.T LEI'I,*-'.5ustpiVIS10 l.o'TS 1-70 13 ; is t 19 GoLL I1�/ ��iw L I . YRo .GT I.� o. 20006151 8 aS. 1 LvT i2 I �o-r 13 LoG.+pl-� : GoJ {tT of lo0 200 300 SUAL� I"� 1001 Empire Laboratories, Inc. A Division of The Terracon Companies, Inc. 7 ,; Terracon �i Phelps Tointon ELi Project No. 20935151 The Geotechnical Engineer should also be retained to provide services during excavation, grading, foundation and construction phases of the work. Observation of footing excavations should be performed prior to placement of reinforcing and concrete to confirm that satisfactory bearing materials are present and is considered a necessary part of continuing geotechnical engineering services for the project. Construction testing of fill placed on the site is considered part of T continuing geotechnical engineering service for the project. Field and laboratory testing of concrete and steel should be performed to determine whether applicable requirements have been met. It would be logical for Empire Laboratories, Inc. to provide these services since we are most qualified to determine consistency of field conditions with those data used in our analyses. The analyses and recommendations in this report are based in part upon data obtained from the field exploration. The nature and extent of variations beyond the location of test borings may not become evident until construction. If variations then appear evident, it may be necessary to reevaluate the recommendations of this report. �{ J Our professional services were performed using that degree of care and skill ordinarily exercised, under similar circumstances, by reputable geotechnical engineers practicing in this or similar localities. No warranty, express or implied, is made. We prepared the report as an aid in design of the proposed project. This report is not a bidding document. Any contractor reviewing this report must draw his own conclusions regarding site conditions and specific construction techniques to be used on this project. This report is for the exclusive purpose of providing geotechnical engineering and/or testing information and recommendations. The scope of services for this project does not include, either specifically or by implication, any environmental assessment of the site or identification of contaminated or hazardous materials or conditions. If the owner is concerned about the potential for such contamination, other studies should be undertaken. We are available to discuss the scope of such studies with you. 19 Terracon Phelps Tointon ELl Project No. 20935151 impervious soil should be used in the upper layer of backfill to reduce the potential for water infiltration. Additional Design and Construction Considerations: • Exterior Slab Design and Construction: Exterior slabs -on -grade, exterior architectural features, and utilities founded on, or in backfill may experience some movement due to the volume change of the backfill. Potential movement could be reduced by: • minimizing moisture increases in the backfill • controlling moisture -density during placement of backfill • using designs which allow vertical movement between the exterior features and adjoining structural elements • placing effective control joints on relatively close centers • allowing vertical movements in utility connections • Underground Utility Systems: All underground piping within or near the proposed structure should be designed with flexible couplings, so minor deviations in alignment do not result in breakage or distress. Utility knockouts in grade beams should be oversized to accommodate differential movements. • Corrosion Protection: Results of soluble sulfate testing indicate that ASTM Type I Portland cement is suitable for all concrete on and below grade. However, if there is no, or minimal cost differential, use of ASTM Type II Portland cement is recommended for additional sulfate resistance of construction concrete. Foundation concrete should be designed in accordance with the provisions of the ACI Design Manual, Section 318-121. GENERAL COMMENTS It is recommended that the Geotechnical Engineer be retained to provide a general review of final design plans and specifications in order that grading and foundation recommendations may be interpreted and implemented. In the event that any changes of the proposed project are planned, the conclusions and recommendations contained in this report should be reviewed and the report modified or supplemented as necessary. 18 Phelps Tointon Terracon ELl Project No. 20935151 The contractor should retain a geotechnical engineer to monitor the soils exposed in all excavations and provide engineering services for such slopes. This will provide an opportunity to monitor the soil types encountered and to modify the excavation slopes as necessary. It also offers an opportunity to verify the stability of the excavation slopes during construction. IDrainage: • Surface Drainage: 1. Positive drainage should be provided during construction and maintained throughout the life of the proposed facility. Infiltration of water into utility or foundation excavations must be prevented during construction. Planters and other surface features which could retain water in areas adjacent to the building or pavements should be sealed or eliminated. 2. In areas where sidewalks or paving do not immediately adjoin the structure, we recommend that protective slopes be provided with a minimum grade of approximately 10 percent for at least 10 feet from perimeter walls. Backfill against footings, exterior walls, and in utility and sprinkler line trenches should be well 'a compacted and free of all construction debris to reduce the possibility of moisture infiltration. 3. Downspouts, roof drains or scuppers should discharge into splash blocks or extensions when the ground surface beneath such features is not protected by J exterior slabs or paving. 4. Sprinkler systems should not be installed within 5 feet of foundation walls. Landscape irrigation adjacent to the foundation system should be minimized or eliminated. k • Subsurface Drainage: Free -draining, granular soils containing less than five percent fines (by weight) passing a No. 200 sieve should be placed adjacent to walls which retain earth. A drainage system consisting of either weep holes or perforated drain lines (placed near the base of the wall) should be used to intercept and discharge water which would tend to saturate the backfill. Where used, drain lines should be embedded in a uniformly graded filter material and provided with adequate clean -outs for periodic maintenance. An +� 17 1 Phelps Tointon Terracon ELl Project No. 20935151 J Maximum Slope Material Horizontal. • Vertical Cohesive soils (clays and silts) ................................ 2:1 Cohesionless soils ........................................ 3:1 Bedrock............................................... 2:1 If steeper slopes are required for site development, stability analyses should be completed to design the grading plan. 2. The face of all slopes should be compacted to the minimum specification for fill embankments. Alternately, fill slopes can be over -built and trimmed to compacted 1 material. • Compliance: Recommendations for slabs -on -grade, foundations and pavement elements supported on compacted fills or prepared subgrade depend upon compliance with "Earthwork" recommendations.. To assess compliance, observation and testing should be performed under the direction of the geotechnical engineer. • Utility Construction: Excavations into the on -site soils will encounter caving soils and possibly groundwater, depending upon the final depth of excavation. The individual contractor(s) should be made responsible for designing and constructing stable, temporary excavations as required to maintain stability of both the excavation sides and bottom. All excavations should be sloped or shored in the interest of safety following local, and federal regulations, including current OSHA excavation and trench safety standards. The soils to be penetrated by the proposed excavations may vary significantly across the site. The preliminary soil classifications are based solely on the materials encountered in widely spaced exploratory test borings. The contractor should verify that similar conditions j exist throughout the proposed area of excavation. If different subsurface conditions are encountered at the time of construction, we recommend that we be contacted immediately to evaluate the conditions encountered. As a safety measure, it is recommended that all vehicles and soil piles be kept to a minimum lateral distance from the crest of the slope equal to no less than the slope height. The exposed slope face should be protected against the elements. 16 Terracon Phelps Tointon ELl Project No. 20935151 • Placement and Compaction: 1. Place and compact fill in horizontal lifts, using equipment and procedures that will produce recommended moisture contents and densities throughout the lift. 2. Uncompacted fill lifts should not exceed 10 inches loose thickness. 3. No fill should be placed over frozen ground. 4. Materials should be compacted to the following: Material Minimum Percent Compaction (ASTM D698) On -site soils: Beneath foundations ................................... 95 Beneath slabs ....................................... 95 Beneath pavements ................................... 95 Imported fill: Beneath foundations ................................... 95 Beneath slabs ....................................... 95 Beneath pavements ................................... 95 Aggregate base (beneath slabs) ................................ 95 Miscellaneous backfill....................................... 90 5. On -site silty clayey sand and sandy lean clay subsoils should be compacted within a moisture content range of optimum moisture content to 2 percent wet of optimum moisture. Imported soils should be compacted within a moisture range of 2 percent below to 2 percent above optimum. • Slopes: 1. For permanent slopes in compacted fill areas, recommended maximum configurations for on -site materials are as follows: 15 Terracon Phelps Tointon ELl Project No. 20935161 3. A minimum 8-inch layer of clean, graded gravel should be placed beneath the floor slab of the south/rear portion of the manufacturing building. • Pavement Subgrade Preparation: The subgrade should be scarified, moistened as required, and recompacted for a minimum depth of 12 inches prior to placement of fill and pavement materials. • Fill Materials: 1. Clean on -site soils or imported materials may be used as fill material for the following: • general site grading • exterior slab areas • foundation areas • pavement areas • interior floor slab areas • foundation backfill 2. Frozen soils should not be used as fill or backfill. 3. Imported soils (if required) should conform to the following: • Gradation (ASTM C136): percent finer by weight 6.. ............................................... 100 3.. ........................................... 70-100 No. 4 Sieve .............................. ..... 50-100 No. 200 Sieve .................................. 15 (max) • Liquid Limit .................................... 30 (max) • Plasticity Index .................................. 15'(max) 4. Aggregate base should conform to Colorado Department of Transportation Class 5 or 6 specifications. 14 Terracon Phelps Tointon ELi Project No. 20935151 • Excavation: 1. It is anticipated that excavations for the proposed construction can be accomplished with conventional earthmoving equipment. 2. Some additional effort may be necessary to extract boulder sized materials, particularly in deep narrow excavations such as utility trenches at a depth of approximately six (6) to seven (7) feet below the surface. 3. Groundwater seepage should be anticipated for excavations approaching the level of groundwater. Pumping from sumps may be utilized to control water within the excavations. Well points may be required for significant groundwater flow, or where excavations penetrate groundwater to a significant depth. 4. On -site clayey sand and/or sandy lean clay soils may pump or become unstable or unworkable at high water contents. Workability may be improved by scarifying and drying. Overexcavation of wet zones and replacement with granular materials may be necessary. Use of lime, fly ash kiln dust, cement or geotextiles could also be considered as a stabilization technique. Adequate laboratory testing should be performed prior to use of chemical stabilization to evaluate the strength characteristics and the affect these materials have on the physical properties of the soils. Lightweight excavation equipment may be required to reduce subgrade pumping. 5. All excavations should be dug on safe and stable slopes. The slope of the sides of the excavations should comply with local codes or OSHA regulations. The side slopes of the excavations should be maintained under safe conditions until completion of backfilling. • Slab Subarade Preparation: 1. Where existing on -site natural soils will support floor slab, the soils should be scarified, moisture conditioned and compacted to a minimum depth of 12 inches. 2. A minimum 4-inch layer of clean graded gravel should be -placed beneath the floor slab of the front/north portion of the manufacturing building. 13 Phelps Tointon Terracon EL/ Project No. 20935151 Earthwork: • Genera/ Considerations: The conclusions contained in this report for the proposed construction are contingent upon compliance with recommendations presented in this section. Although fills or underground facilities such as septic tanks, cesspools, basements, utilities were not observed during site reconnaissance, such features might be encountered during construction. • Site C/ear/n4: 1. Strip and remove existing vegetation, debris, and other deleterious materials from proposed building and pavement areas. All exposed surfaces should be free of mounds and depressions which could prevent uniform compaction. 2. If unexpected fills or underground facilities are encountered during site clearing, such features should be removed, the excavation thoroughly cleaned and backfilled. All excavations should be observed by the geotechnical engineer prior to backfill placement. 3. Stripped materials consisting of organic materials should be wasted from the site, or used to revegetate exposed slopes after completion of grading operations. If it is necessary to dispose of organic materials on -site, they should be placed in non- structural areas, and in fill sections not exceeding 5 feet in height. J 4. Sloping areas steeper than 2:1 to 3:1 (horizontal:vertical) should be benched to reduce the potential for slippage between existing slopes and fills. Benches should rbe level and wide enough to accommodate compaction and earth moving equipment. 5. The site should be initially graded to create a relatively level surface to receive fill, and to provide for a relatively uniform thickness of fill beneath proposed building structures. 6. All exposed areas which will receive fill, once properly cleared and benched where necessary, should be scarified to a minimum depth of twelve inches, conditioned to near optimum moisture content, and compacted. 12 Phelps Tointon Terracon ELl Project No. 20935151 • Maintaining stable moisture content of the subgrade soils; and, • Providing for a planned program of preventative maintenance. Since the clay soils on the site have shrink/swell characteristics, pavements could crack in the future primarily because of expansion of the soils when subjected to an increase in moisture content to the subgrade. The cracking, while not desirable, does not necessarily constitute structural failure of the pavement. The performance of all pavements, but in particular the recommended asphalt sections, can be enhanced by minimizing excess moisture which can reach the subgrade soils. The following recommendations should be considered at minimum: • Site grading at a minimum 2% grade away from the pavements; • Compaction of any utility trenches for landscaped areas to the same criteria as the pavement subgrade; • Sealing all landscaped areas in, or adjacent to pavements to minimize or prevent moisture migration to subgrade soils; • Placing compacted backfill against the exterior side of curb and gutter; and; I • Placing curb, gutter and/or sidewalk directly on subgrade soils without the use of base course materials. Preventative maintenance should be planned and provided for through an on -going pavement management program in order to enhance future pavement performance. Preventative maintenance activities are intended to slow the rate of pavement deterioration, and to preserve the pavement investment. Preventive maintenance consists of both localized maintenance (e.g. crack sealing and patching) and global maintenance (e.g. surface sealing). Preventative maintenance is usually the first priority when implementing a planned pavement maintenance program and provides the highest return on 1 investment for pavements. II Recommended preventative maintenance policies for asphalt and jointed concrete pavements, based upon type and severity of distress, are provided in Appendix D. Prior to implementing any maintenance, additional engineering observation is recommended to determine the type, and extent of preventative maintenance. 11 Phelps Tointon Terracon ELl Project No. 20935151 Asphalt concrete should be obtained from an approved mix design stating the Marshall or Hveem properties, optimum asphalt content, job mix formula, and recommended mixing and placing temperatures. Aggregate used in asphalt concrete should meet a particular gradation. Use of materials meeting Colorado Department of Transportation Grading C or CX specifications is recommended. The mix design should be submitted prior to construction to verify its adequacy. The asphalt material should be placed in maximum 3-inch lifts, and should be compacted to a —, minimum of 95% Marshall or Hveem density (ASTM D-1559). �j • Rigid Pavement: Where rigid pavements are used the concrete should be obtained from an J approved mix design with the following minimum properties: • Compressive Strength @ 28 days ................... 3750 psi minimum • Modules of Rupture @ 28 days ..................... 700 psi minimum • • Strength Requirements .............. Minimum Cement Content .............. • • • ASTM C-94 5.5 sacks/cu.yd. • Cement Type .................................... Type I Portland • • Entrained Air Content ................ Concrete Aggregate • ............. • • • 6% + 2% ASTM C-33 and COOT Section 703 0 • Aggregate Size ................................. Maximum Water Content ....................... 1 inch maximum 0.49 lb/lb of cement • Maximum Allowable Slump ............................... 4 inches I Concrete should be deposited by truck mixers or agitators and placed a maximum of 90 minutes from the time the water is added to the mix. Other specifications outlined by the Colorado Department of Transportation should be followed. J i J, 0 Longitudinal and transverse joints should be provided as needed in concrete pavements for expansion/contraction and isolation. The location and extent of joints should be based upon the final pavement geometry and should be spaced (in feet), at roughly twice the slab thickness (in inches), on center in either direction. Sawed joints should. be cut within 24-hours of concrete placement, and .should be a minimum depth of 25% of slab thickness plus -1 /4 inch. All joints should be sealed to prevent entry of.foreign material and dowelled where necessary for load transfer. Where dowels cannot be used at joints accessible to wheel loads, pavement thickness should be increased by 25 percent at the joints and tapered to regular thickness in 5 feet. Future performance of pavements constructed on the clay soils at this site will be dependent upon several factors, including: 10 J Phelps Tointon Terracon ELI Project No. 20935151 Recommended Pavement Section Thickness (Inches) Asphalt Concrete Surface Aggregate Base Course Plant Mix Bituminous Base Course Portland Cement Concrete TOTAL Traffic Area Alternative A 2.5 4.0 6.5 Automobile B 2.0 2.0 4.0 Parking C 5.0 5.0 A 3.0 6.0 9.0 Main Traffic Corridors/ B 2.0 3.5 5.0 Truck Access C 6.0 6.0 Each alternative should be investigated with respect to current material availability and economic conditions. In view of the subgrade soil conditions and projected traffic, either full -depth asphalt or rigid concrete pavement sections should be considered in areas of main traffic corridors, drive bays or truck access. Rigid concrete pavement is recommended at the location of dumpsters where trash trucks will park and load. Aggregate base course (if used on the site) should consist of a blend of sand and gravel which meets strict specifications for quality and gradation. Use of materials meeting Colorado Department of Transportation Class 5 or 6 specifications is recommended. In addition, the base course material should be moisture stable. Moisture stability is determined ' by R-value testing which shows a maximum 12 point difference in R-values between exudation pressures of 300 psi and 100 psi. Aggregate base course material should be tested to determine compliance with these specifications prior to importation to the site. Aggregate base course should be placed in lifts not exceeding six inches and should be compacted to a minimum of 95% Standard Proctor density (ASTM D-698), within a moisture content range of 2 percent below, to 2 percent above optimum. Where base course thickness exceeds 6 inches, the material should be placed and compacted in two or more lifts of equal thickness. 9 L Terracon Phelps Tointon ELi Project No. 20935151 • Interior trench backfill placed beneath slabs should be compacted in accordance with recommended specifications outlined below. • In areas subjected to normal loading, a minimum 4-inch layer of clean graded gravel should be placed beneath the interior slab for heavy loading areas such as the south or rear portion of the building. A minimum 8-inch layer of clean graded gravel should be placed beneath the interior slab. • If moisture sensitive floor coverings are used on interior slabs, consideration should be given to the use of barriers to minimize potential vapor rise through the slab. • Floor slabs should not be constructed on frozen subgrade. • Other design and construction considerations, as outlined in the ACI Design Manual, Section 302.1 R are recommended. Pavement Design & Construction: • Flexible Pavement: It is our opinion flexible pavement is suitable for the proposed parking area associated with the construction of the manufacturing building. The required total thickness for the pavement structure is dependent primarily upon the foundation soil or subgrade and upon traffic conditions based on soil conditions encountered at the site and the type and volume of traffic using a group index of two (2) as a criteria for pavement design. The following minimum pavement thicknesses should be provided of the pavement structure. 0 Phelps Tointon Terracon ELI Project No. 20935151 • Passive: Cohesive soil backfill (on -site clay and/or clayey sand) :: ; :.::::: . 200 psf/ft Shallow foundation walls . 255 psf/ft Imported Granular Backfill ............................... 300 psf/ft Where the design includes restrained elements, the following equivalent fluid pressures are recommended: • At -rest: Cohesive soil backfill (on -site clay) ......: ........... : :.... 60 psf/ft Cohesive Structural Fill 55 psf/ft Imported Granular Backfill................................ 55 psf/ft Seismic Considerations: The project site is located in Seismic Risk Zone I of the Seismic Zone Map of the United States as indicated by the Uniform Building Code. Based upon' the nature of the subsurface materials, a seismic site coefficient of 1.0 should be used for the design of structures for the proposed project (Uniform Building Code, Table No. 23-J). Floor Slab Deg n and Construction: Non -expansive, or only low expansive soils will support the floor slab. Some differential movement of a slab -on -grade floor system is possible should the subgrade soils become elevated in moisture content. Such movements are considered within general tolerance for normal slab -on -grade movements. To reduce any potential slab movements, the subgrade soils should be prepared as outlined in the earthwork section of this report. For structural design of concrete slabs -on -grade, a modules of subgrade reaction of 100 pounds per cubic inch (pci) may be used for floors supported on existing or engineered fill consisting of on -site soils. A modules of 200 pci may be used for floors supported on non -expansive imported fill meeting the specifications outlined below. Additional floor slab design and construction recommendations are as follows: • Positive separations and/or isolation joints should be provided between slabs and all foundations, columns or utility lines to allow independent movement. 0 Contraction joints should be provided in slabs to control the location and extent of cracking. Maximum joint spacing of 15 to 20 feet in each direction is recommended. 7 Terracon Phelps Tointon ELl Project No. 20935151 undisturbed subsoils, recompacted native soils and/or engineered fill material is recommended for support of the proposed structure. The footings may be designed for a maximum bearing pressure of 1,500 pounds per square foot (psf). In addition, the footings should be sized to maintain a minimum deadload of 500 psf. Exterior footings should be placed a minimum of 30 inches below finished grade for frost protection. Interior footings should bear a minimum of 12 inches below finished grade. The bottom of the footings and/or grade beams should be located a minimum of two (2) feet above groundwater level at an elevation of 92 or higher (see Log of Borings in Appendix A). Footings should be proportioned to minimize differential foundation movement. Proportioning on the basis of equal total settlement is recommended; however, proportioning to relative constant dead -load pressure will also reduce differential settlement between adjacent footings. Total or differential settlements resulting from the assumed structural loads are estimated to be on the order of % inch or less, provided that: • foundations are constructed as we recommend, and • essentially no changes occur in water contents of foundation soils. Additional foundation movements could occur if water from any source infiltrates the foundation soils; therefore, proper drainage should be provided in the final design and during construction. All footings, foundation walls, and masonry walls should be reinforced to reduce the potential for distress caused by differential foundation movements. The use of joints at openings or other discontinuities in masonry walls is recommended. Foundation excavations should be observed by the geotechnical engineer. If the soil conditions encountered differ significantly from those presented in this report, supplemental recommendations will be required. Lateral Earth Pressures: For soils above any free water surface, recommended equivalent fluid pressures for unrestrained elements are: • Active: Cohesive soil backfill (on -site clay or silt) ..................... 50 psf/ft Cohesionless soil backfill (on -site silty sand with gravel) ........... 40 psf/ft Cohesive Structural Fill (imported clay material) ................. 55 psf/ft Compacted imported granular backfill ........................ 35 psf/ft L Phelps Tointon Terracon ELI Project No. 20935151 medium dense to dense and exhibits generally moderate bearing characteristics in its in -situ condition. Laboratory Test Results: Laboratory test results indicate that the on -site subsoils at shallow depths have low expansive potential. The water is added to the on -site subsoil material at shallow depths and upon loading, consolidation occurs. Groundwater Conditions: Groundwater was encountered at depths of four and one-half (4'/2) to five and one-half (5'/2) feet below the surface in the test borings at the time of field exploration. When checked 24 hours after drilling, groundwater was also encountered at depths of four and one-half (4'/2) to five and one-half (5'/2) feet below the surface. These observations represent only current groundwater conditions, and may not be indicative of other times, or at other locations.. Groundwater levels can be expected to fluctuate with varying seasonal and weather conditions. CONCLUSIONS AND RECOMMENDATIONS The site appears suitable for the proposed manufacturing building construction. There are no known geologic hazards which would preclude development as currently planned. Because of variations in the engineering properties of the on -site soils, foundation bearing levels, structural loads and possible final grades, the following foundation systems were evaluated for use on the site. • conventional -type spread footings and/or continuous grade beams bearing on the undisturbed soil; and 0 conventional -type spread footings and/or continuous grade beams bearing on engineered fill. Slab -on -grade construction is considered acceptable for use when subgrade soils consist of the on -site sandy lean clay or the silty clay sand or approved engineered fill material provided the design and construction recommendations discussed in the "Earthwork" section of this report are followed. Site grading for the proposed construction should be completed in accordance with the recommendations discussed in the "Earthwork" section of this report. Foundation Systems: Due to the presence of low expansive swelling soils at the site, conventional -type spread footings and/or continuous grade beam foundation systems bearing on 5 Phelps Tointon Terracon ELl Project No. 20935151 causing the uplifting of the Front Range and the associated downwarping of the Denver Basin to the east. Relatively flat uplands and broad valleys characterize the present-day topography of the Colorado Piedmont in this region. The Pierre shale underlies site at approximate depths of 20 to 30 feet below the surface. The regional dip of bedrock in this area is slight and in an easterly direction. Seismic activity in the area is anticipated to be low and from a structural standpoint, the property should be relatively stable. Groundwater underlies the subject site at depths of approximately four and one-half (4Y:) to five and one-half (5'/:) feet below the surface. The property lies within the drainage basin of the Cache La Poudre River. Groundwater directional flow at the site is anticipated to be in a southeasterly direction towards Cache La Poudre River which is located approximately one-half (Yz) mile south of the subject site. Soil Conditions: The profile at the site consists of stratum of materials arranged in different combinations. In order of increasing depths, they are as follows. 1. Silty Topsoil. The area tested is overlain by a one-half (Yz) foot layer of silty topsoil. The 7 topsoil has been penetrated by root growth and organic matter and should not be used as a bearing soil or as a fill and/or backfill material. J2. Silty Clayey Sand. This brown, moist to damp, loose to medium dense, silty clayey sand material was encountered below the topsoil in test borings 1, 2 3, and 5 and extends to 7 a depth of three (3) to five (5) feet below the surface. The silty clayey sand material exhibits moderate bearing characteristics in its moist to damp in -situ condition. J3. Sandy Lean Clay. This cohesive, tan to light brown, moist, medium stiff sandy lean clay was encountered below the topsoil in test boring No. 4 and extends to a depth of four (4) feet below the surface. The sandy lean clay is plastic, moist and exhibits moderate bearing characteristics in its moist, in -situ condition. 4. Silty Sand and Gravel. This granular, silty sand with gravel stratum was encountered in all five (5) test borings at a depth of three (3) to five (5) feet below the surface and extends beyond the depths explored. Cobbles ranging in the size of three (3) to six (6) inches in diameter were encountered within the silty sand with gravel stratum at depths of five (5) to six and one-half (6Yz) feet below the surface. The granular stratum varies in from a silty sand with gravel to a relatively clean sand with gravel and cobbles. It is 4 Terracon Phelps Tointon ELI Project No. 20935151 Laboratory Testing: All samples retrieved during the field exploration were returned to the laboratory for evaluation by the project geotechnical engineer, and were classified in accordance with the Unified Soil Classification system described in Appendix C. At that time, the field descriptions were confirmed or modified as necessary, final boring logs prepared, and an applicable laboratory testing program was formulated to determine engineering properties of the subsurface materials. Boring Logs for the project are presented in Appendix A. Selected soil samples were tested for the following engineering properties: • Water content 0 Swell consolidation • Dry density • Plasticity • Unconfined Compressive Strength • Soluble sulphate content • Expansion The significance and purpose of each laboratory test is described in Appendix C. Laboratory test results are presented in Appendix B, and were used for the geotechnical engineering analyses, and the development of foundation and earthwork recommendations. All laboratory test were performed in general accordance with applicable ASTM, local or other accepted standards. SITE CONDITIONS The site for the proposed office/manufacturing building is currently a vacant tract of land. Vegetation at this site consists of relatively short growth of medium to dense grass and weeds. The site is relatively flat with minor surface drainage in the south to southeast direction. The property is bordered on the north by Buckingham Street and to the east by vacant land with North Lemay located beyond. South of the subject site is the Vanworks shop and southeast of the site are storage units. West of the site is also vacant land. SUBSURFACE CONDITIONS Geology: The proposed area is located within the Colorado Piedmont section of the Great Plains physiographic province. The Colorado Piedmont, formed during Late Tertiary and Early quaternary time (approximately two million (2,000,000) years ago), is a broad, erosional trench which separates the Southern Rock Mountains from the High Plains. Structurally, the site lies along the western flank of the Denver Basin. During the Late Mesozoic and Early Cenozoic Periods (approximately seventy million (70,000,000) years ago), intense tectonic activity occurred, 3 Terracon Phelps Tointon ELI Project No. 20935151 Other site development will include the construction of a parking lot to the north, east and west of the proposed building location. Two levels of traffic are anticipated for pavements to be constructed on the site. These include automobile parking and drive bays/truck access. SITE EXPLORAT/ON The scope of the services performed for this project included site reconnaissance by a geotechnical engineer, a subsurface exploration program, laboratory testing and engineering analyses. Field Exploration: A total of five (5) test borings were drilled at the subject site on June 11, 1993 to depths of fifteen (15) below the surface at the locations shown on the Site Plan, Figure 1. The test borings were drilled within the footprint of the proposed manufacturing building structure. The test borings were advanced with a truck -mounted drilling rig utilizing 4-inch diameter continuous -type power flight auger drills. The location of borings were positioned in the field by ELI with reference to the north and east property lines. Elevations were taken at the ground surface of each test boring location by measurements with an engineer's level and rod relative to a temporary benchmark consisting of the north bonnet bolt of the fire hydrant located on the south side of Buckingham Street approximately 300 feet east of the proposed structure. The TBM is assumed at an elevation of 100. The accuracy of boring locations and elevations should only be assumed to the level implied by the methods used to determine each. Continuous lithologic logs of each boring were recorded by the engineering geologist during the drilling operations. At selected intervals, samples of the subsurface materials were taken by means of pushing thin -walled Shelby tubes, or by driving split -spoon sampling devices. Penetration resistance measurements were taken with each sampling with the split -spoon driving the sampler with a 140-pound hammer falling 30 inches. When properly interpreted, the penetration resistance is a useful index to the consistency, relative density or hardness of the materials encountered. Groundwater conditions were evaluated in each boring at the time of site exploration, and 24 hours after drilling. 2 GEOTECHN/CAL ENGINEERING REPORT PROPOSED MANUFACTURING BUILDING LOTS 12, 73, 18 AND 19 OF THE NORTH LEMAY SUBDIVISION FORT COLLINS, COLORADO ELI PROJECT NO. 20935151 INTRODUCTION Terracon This report contains the results of our geotechnical engineering exploration prepared for the proposed manufacturing building to be located on lots 12, 13, 18 and 19 of the North Lemay Subdivision 2nd Filing in northeast Fort Collins, Colorado. The site is located. in the northeast quarter of Section 12, Township 7 North, Range 69 West of the 6th Principal Meridian, Larimer County, Colorado. The purpose of these services is to provide information and geotechnical engineering recommendations relative to: • subsurface soil conditions • groundwater conditions • foundation design and construction • lateral earth pressures • floor slab design and construction • pavement design and construction • earthwork • drainage The conclusions and recommendations contained in this report are based upon the results of field and laboratory testing, engineering analyses, and experience with similar soil and structural conditions. PROPOSED CONSTRUCTION Based on information provided by Mr. Tim Brown of Colorado Custom Cabinets, the proposed structure will consist of a steel frame, slab -on -grade, two-story office portion and single -story manufacturing building having plan dimensions of 160x250 feet. Final site grading plans were not available prior to preparation of this report. Ground floor level is anticipated at the proposed office/manufacturing building at existing grade to approximately two (2) feet above existing grade. Phelps Tointon EL/ Project No. 20935151 TABLE OF CONTENTS (cont.) Page No. APPENDIX A Site Plan .............................................. Figure No. 1 Logs of Borings .......................................... A2 thru A6 APPENDIX B Laboratory Test Data: Swell -Consolidation Tests .................................... 61 Summary of Test Results .............................. B2 thru B3 APPENDIX C: GENERAL NOTES Drilling & Exploration ............................................. C1 Unified Soil Classification ......................................... C2 Laboratory Testing, Significance and Purpose ........................... C3 Report Terminology ............................................. C4 APPENDIX D Recommended Preventative Maintenance -Asphalt Concrete Pavements ......... D1 Recommended Preventative Maintenance -Jointed Concrete Pavements ......... D2 Phelps Tointon ELi Project No. 20935151 TABLE OF CONTENTS No. Letter of Transmittal ...............................................Page i INTRODUCTION..................................................... 1 PROPOSED CONSTRUCTION ........................................... 1 SITE EXPLORATION .................................................. 2 J Field Exploration ........................ 2 Laboratory Testing ............................................ 3 7 SITE CONDITIONS ................................................... 3 SUBSURFACE CONDITIONS ............................................ 3 J Geology ..................................................... 3 Soil Conditions 4 Laboratory Test Results .......................................... 5 JGroundwater Conditions .......................................... 5 CONCLUSIONS AND RECOMMENDATIONS ................................. 5 Foundation Systems . 5 J Lateral Earth Pressures ........................................... 6 Seismic Considerations ........................................... 7 Floor Slab Design and Construction ................................ 7 Pavement Design & Construction 8 Flexible Pavement ......................................... 8 Rigid Pavement 10 J Earthwork ........................................... 12 General Considerations ..................................... 12 Site Clearing 12 Excavation ........ 13 Slab Subgrade Preparati..................................... on ................................... 13 Pavement Subgrade Preparation .................:.:.... ...:.. 14 Fill Materials 14 Placement and Compaction .................................. 15 Slopes................................................ 15 Compliance............................ 16 Utility Construction ....................................... 16 17 Drainage.................................................... Surface Drainage ................................. 17 Subsurface Drainage ......... 17 Additional Design and Construction Considerations ...................... 18 1 Exterior Slab Design and Construction .......................... 18 y Underground Utility Systems 18 Corrosion Protection ....................................... 18 GENERAL COMMENTS ............................................... 18 Terracon Phelps Tointon ELI Project No. 20935151 We have appreciated being of service to you in the geotechnical engineering phase of this project, and are prepared to assist you during the construction phases as well. If you have any questions concerning this report or any of our testing, inspection, design and consulting services, please feel free to contact us. Sincerely, EMPIRE LABORATORIES, INC. A Division of a Terracon Companies, Inc. �q 4.4 David A. Richer, P.E. Geotechnical Engineer Reviewed by: Chester C. Smith, P.E. Division Manager DAR/CCS/dmf Copies to: Phelps Tointon (3) Empire Laboratories, Inc. A Division of The Terracon Companies, Inc. P.O. Box 503 a 301 No. Howes Fort Collins, Colorado 80522 (303) 484-0359 FAX No. (303) 484-0454 Chester C. Smith, P.E. Neil R. Sherrod, C.P.G. June 21, 1993 Phelps Tointon P.O. Box 1518 Greeley, Colorado 80634 Attn: Mr. Brian Tointon Re: Geotechnica/ Engineering Report, Proposed Manufacturing Building, Lots 12, 13, 18 and 19 of the North Lemay Subdivision Fort Collins, Colorado EL/ Project No. 20935151 Empire Laboratories, Inc. (ELI) has completed a geotechnical engineering exploration for the proposed manufacturing building to be located on lots 12, 13, 18 and 19 of the North Lemay Subdivision in Fort Collins, Colorado. The results of our engineering study, including the boring location diagram, laboratory test results, test boring records, and the geotechnical recommendations needed to aid in the design and construction of foundations and other earth connected phases of this project are attached. The subsurface exploration indicated soil conditions which are typical of soils commonly found in the northeast Fort Collins area. The subsurface soils at the site consisted predominately of a silty sand with gravel material overlain by a clayey sand layer. The information obtained by the results of the field exploration and laboratory testing completed for this project indicate the soils at the site have a low expansive potential. Based on the geotechnical engineering analyses, subsurface exploration and laboratory test results, it is recommended that the proposed structure be supported on a conventional -type spread footing, and/or continuous grade beam foundation system. Slab -on -grade may be utilized for the interior floor system provided that care is taken in the placement and compaction of the subgrade soil. Other design and construction details, based upon geotechnical conditions, are presented in the report. Offices of The Terracon Companies, Inc. Geotechnical, Environmental and Materials Engineers Arizona: Tucson ■ Colorado: Colorado Springs, Denver, Ft. Collins, Greeley, Longmont ■ Idaho: Boise ■ Illinois: Bloomington, Chicago, Rock Island ■ Iowa: Cedar Falls, Cedar Rapids, Davenport, Des Moines, Storm Lake 0 Kansas: Lenexa, Topeka, Wichita ■ Minnesota: St. Paul ■ Missouri: Kansas City ■ Nebraska: Lincoln, Omaha ■ Nevada: Las Vegas ■ Oklahoma: Oklahoma City, Tulsa ■ Texas: Dallas ■ Utah: Salt Lake City ■ Wyoming: Cheyenne QUALITY ENGINEERING SINCE 1965 GEOTECHN/CAL ENGINEERING REPORT PROPOSED MANUFACTURING BUILDING LOTS 12, 13, 18 AND 19 OF THE NORTH LEMAY SUBDIVISION FORT COLLINS, COLORADO ELI PROJECT NO. 20935151 Prepared for: PHELPS TOINTON P.O. BOX151B GREELEY, COLORADO 80634 ATTN: MR. BRAN TO/NTON Empire Laboratories, Inc. A Division of The Terracon Companies, Inc. i GEOTECHN/CAL ENGINEERING REPORT PROPOSED MANUFACTURING BUILDING LOTS 12, 13, 18 AND 19 OF THE NORTH LEMAY SUBDIVISION FORT COLLINS, COLORADO ELI PROJECT NO. 20935151 A Division of The Terracon Companies, Inc.