HomeMy WebLinkAboutGROWTH LEASING COLORADO - BDR190008 - SUBMITTAL DOCUMENTS - ROUND 3 - STAFF'S PROJECT COMMENTSDepartment: Building Services
Contact: Katy Hand, 970-416-4272, khand@fcgov.com
Topic: Building Insp Plan Review
Comment Number: 3
04/22/2019: BUILDING PERMIT:
This building is required to be provided with a fire sprinkler system in
accordance with NFPA 13 or must be provided with a method of fire
containment (ie: fire areas).
Comment Number: 4
04/22/2019: BUILDING PERMIT:
Be advised that conditioned buildings are required to provide air barrier details
at building permit plan review and pass a blower door test (<.25cfm/75) prior to
issuance of the Certificate of Occupancy.
Department: PFA
Contact: Andrew Rosen, 970-416-2599, arosen@poudre-fire.org
Topic: General
Comment Number: 1
07/02/2019: INFORMATION ONLY:
GATE - Please note that a Knox Key Switch is appropriate for the entrance gate and a
Knox Box is appropriate for the building entrance.
Comment Number: 8
05/29/2019: BUILDING PERMIT:
Please note that PFA will have further comments regarding the Hazardous
Materials and their storage on the site at time of building plan permit.
Department: Technical Services
Contact: Jeff County, 970-221-6588, 'county@fcqov.com
Topic: Site Plan
Comment Number: 4
06/25/2019: FOR APPROVAL -UPDATED:
There are line over text issues. See redlines.
06/05/2019: FOR APPROVAL -UPDATED:
There are line over text issues. See redlines.
04/24/2019: FOR APPROVAL:
There are line over text issues. See redlines.
Comment Number: 13
06/25/2019: FOR APPROVAL:
There are cut off text issues. See redlines.
2
Fort Collins
./110'� -
July 03, 2019
Tom Orfanos
Growth Leasing LLC
3019 Duportail Street #177
Richland, WA 99352
RE: Growth Leasing Colorado, BDR190008, Round Number 3
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6689
970.224.6134 - fax
rcgov. com/developmentreview
Please see the following summary of comments from City staff and outside reviewing
agencies for your submittal of the above referenced project. If you have questions about
any comments, please contact your Development Review Coordinator Brandy Bethurem Harras at
970.416.2744 or bbethuremharras@fcgov.com.
Comment Summary:
Department: Planning Services
Contact: Kai Kleer, 970-416-4284, kkleer@fc_qov.com
Topic: General
Comment Number: 12
06/03/2019 INFORMATION ONLY:
No other comments, ready to present to decision maker.
Department: Light And Power
Contact: Cody Snowdon, 970-416-2306, csnowdon@fcaov.com
Topic: General
Comment Number: 6
06/20/2019: INFORMATION ONLY:
It is understood that the design of the mechanic systems is not at the level to
accurately provide a C-1 Form and One -Line Diagram, but I did want to note the
risk involved with not providing that information at this stage in the process. If
the overall commercial use requires additional transformers, it could result in
plan revisions. As long as this is understood by the Development Team, Light
and Power has no further comments and is ready for mylar.