Loading...
HomeMy WebLinkAboutRAINTREE TOWNHOMES PUD PRELIMINARY - 42 93 - SUBMITTAL DOCUMENTS - ROUND 1 - TRAFFIC STUDYeast and north of the Senior Center. Without this access easement, these properties would be restricted to right-in/right-out access to Shields Street. Conversely, the right-in/right-out access to Shields Street is recommended in order to reduce the traffic volumes at the Senior Center main access. 5 will be at level of service B and C. The intersections along Raintree Drive will be at level of service A for all movements. The right-in/right-out access to Shields Street is recommended because it will greatly reduce the "non Senior Center traffic" that ' will be using the main access due to the access easement which will be provided. The right-in/right-out access to Shields Street will operate acceptably. It is recommended that this access be located on/near the property line between the vacant parcel and the parcel ' on which the 12 dwelling units are being considered. This location will provide a single point of access while serving two properties. This location is about 300 feet south of Raintree Drive. It is recommended that the right-in/right-out have a right -turn auxiliary ' lane. Provision of this auxiliary lane will move the west curb of Shields Street about 10 feet to the west. It will likely use the ' sidewalk area on sidewalk and bike the bridge that crosses the path can be provided on a New Mercer Canal. The separate structure to the west of the existing bridge. ' A long range analysis was not performed. Peak hour traffic volumes on Shields Street are expected to grow modestly over the next 20 years. Traffic growth on Shields Street will likely occur during the non -peak hours. The signalized Shields/Raintree/Centre intersection will operate acceptably for many years into future. Acceptable operation will occur at the Raintree stop sign ' controlled intersections with a more than five times increase of the traffic volumes shown in Figure 6. It is not likely that future uses along Raintree Drive will create a five times increase in traffic. III. Conclusions The following summarizes the significant findings as a result ' of this study: The Fort Collins Senior Center traffic can be accommodated on the area streets. - Current traffic operation at the area intersections is acceptable. ' - In the short range future (1995) with the Senior Center traffic, the key intersections operate acceptably. ' - In the short range future (1995) with the traffic from the Senior Center, fast food restaurant, and 12 dwelling units, the key intersections will operate acceptably. ' - The access easement in the southeast corner of the Senior Center parcel will provide better access to the properties to the ' 4 1 / --- 339/42/25 I N � N n ncn N cm N 37/5� 28 m v c " w �-- 54 109/136 7/13/4 I� jz M 8/16/135 IN } 275/5 0 /r / 1 /� �-15 30 25 ! 1 2/5/2 RAINTREE 17/25/164 51/132/83� + C 19/32/21 4/20 15 - 0/1 /1--� �� to4 � z m 11 -+- 6/34 34� co too t^-c. o \ c� N W) M� 0 LEGEND I AM / NOON / PM 1995 PEAK HOUR TRAFFIC WITH SENIOR CENTER, FAST FOOD RESTAURANT AND 12 DWELLING UNITS N Figure 6 Table 3 1995 Peak Hour Operation With Senior Center Level of Service Intersection AM Noon PM Shields/Raintree/Centre (signal) 6 Phase B B C Raintree/Shopping Center Access/ Senior Center Access (stop sign) NB LT/T/RT A A A SB LT/T/RT A A A EB LT A A A WB LT A A A Raintree/West Access to Senior Center (stop sign) SB/LT/RT •A A A EB LT A A A Table 4 1995 Peak Hour Operation With Senior Center, Fast Food Restaurant, & 12 D.U. Level of Service Intersection AM Noon PM Shields/Raintree/Centre (signal) 6 Phase B B C Raintree/Shopping Center Access/ Senior Center Access (stop sign) NB LT/T/RT A A A SB LT/T/RT A A A EB LT A A A WB LT A A A Raintree/West Access to Senior Center (stop sign) SB/LT/RT A A A EB LT A A A Shields/Right-in/Right-out (stop sign) EB RT A A B a so development. The roads considered for the operations analysis are Raintree Drive and Shields Street. Background traffic for impacted streets was projected for 1995 for the Senior Center alone and for the Senior Center with the previously discussed uses that would utilize the Senior Center access. The through traffic on Shields Street was assumed to increase at the rate of three percent to the year 1995. The site generated traffic is added to the background traffic. Trip Distribution Trip distribution was determined based upon an evaluation of trip productions and the most likely routes available to travel from those productiohs. The directional distribution of the approaching and departing traffic generated at the Senior Center is a function of: Geographic location within the City of Fort Collins; Location of employment/business centers and residential uses which are likely to produce trips; Access to the site. Figure 4 illustrates the trip distribution percentages used in the subsequent traffic assignments. Traffic Assignment and Intersection Operation Using the vehicular trip generation estimates presented in Table 2, the site generated traffic was assigned to the area street network. The street network consisted of Shields Street and Raintree Drive as they are today. The analyzed intersections, were Shields/Raintree/Centre with signalization, and the accesses to this site from Raintree Drive. The previously discussed right- in/right-out to Shields Street was also analyzed. Figure 5 shows the short range (1995) peak hour traffic assignment. This assignment also includes the increase in background traffic as described earlier in this report and the ' traffic generated by the Senior Center. Table 3 shows the peak hour operation at the, key intersections. Calculation forms are provided in Appendix D. The signalized Shields/Raintree/Centre intersection will be at level of service B and C during the peak hours. The accesses to Raintree Drive will be at level of service A for all movements. tFigure 6 shows the short range (1995) peak hour traffic assignment, which includes background traffic on the area streets, the Senior Center traffic, and the traffic generated by the adjacent uses as discussed earlier. Table 4 shows the peak hour operation at the key intersections. Calculation forms are provided in Appendix E. The Shields/Raintree/Centre signalized intersection ' 3 1 1 1 1 1 1 1 ential 't-in t-in /Right -out SHIELDS �Z STREET NO SCALE Assumed as Future Fast Food Restaurant I I(Existing Private I Residence) I I Future y Access Easement c � I � 1 pf 3 N L_J p 6 IN N Raintree Shopping Center SITE PLAN Figure 3 11 0 M operation is acceptable and the overall intersection operation is acceptable. Analyses performed for the future conditions assumed ■ a six phase signal. ' III. Proposed Development The Fort Collins Senior Center is proposed on a 5 acre parcel of land west of Shields Street and north of Raintree Drive. A schematic site plan is shown in Figure 3. It is proposed that the main access will be across from the Shopping Center access. A I ' secondary access will be located further to the west along Raintree Drive. A third access may be built as the .parking area expands to the west. There is an existing private residence and a small vacant parcel east of the proposed Senior Center. While no proposals have been put forth for these properties, it is likely that they will ' be redeveloped as a commercial use. For analysis purposes, it was assumed that these parcels would be combined and have a fast food restaurant. This was considered to be the likely highest 'intensity ' use for this site. At a meeting involving all the adjacent property owners, it was agreed that an access to this commercial parcel would occur via an access easement through the Senior Center main access to Raintree. Drive. Right-in/right-out access from ' Shields Street to this parcel was also discussed. . The property north of the proposed Senior Center is being ' considered for development with 12 dwelling units. Access to this property would be via Shields Street. It was suggested in the aforementioned meeting that access to this parcel from Shields Street be shared with the future commercial parcel. This access to Shields Street would be right-in/right-out. Therefore, both of these adjacent properties would have access via the easement to the Senior Center main access. 1 Trip Generation ' Trip generation estimates for the adjacent uses were obtained from Trip Generation, 5th Edition, ITE. The trip generation for the Senior Center was estimated based upon conversations with Fort Collins Senior Center staff. Table 2 shows .the trip generation used for the various uses considered in this study. Background Traffic Background traffic is defined as the traffic that is and/or will be on the area streets but is not related to the proposed ' 2 1 I Table 1 1992 Peak Hour Operation Level of Service Intersection AM Noon PM Shields/Raintree/Centre (signal) 4 Phase B B B 6 Phase B B C Raintree/Shopping Center Access (stop sign) NB LT/RT A A A WB LT A A A Table 2 Trip Generation A.M Peak Daily (Noon Peak) P.M. Peak Land Use Trips Trips Trips Trips Trips in out in out Senior Center 700 30 10 20 50 (60) (60) 12 Dwelling Units 120 2 7 8 4 (5) (5) Fast Food - 2.0 KSF 1260 57 34 38 35 (61) (59) a go FORT COLLINS SENIOR CENTER SITE ACCESS STUDY FORT COLLINS, COLORADO OCTOBER 1992 Prepared for: City of Fort Collins 300 LaPorte Avenue Fort Collins, CO 80521 Prepared by: MATTHEW J. DELICH, P.E. 3413 Banyan Avenue Loveland, CO 80538 Phone: 303-669-2061 z r z a m Cl) vU W d s t3 J W 0 -13 Q W Q rE July 12, 1993 o Mr. Mike Herzig Fort Collins Development Engineer o P.O. Box 580 o Fort Collins, CO 80522-0580 (File: 9350LT01) Dear Mike: Raintree Townhouses PUD is proposing to build a 28 foot wide public street within the development. According to the Fort Collins Design Criteria and Standards for Streets, this street width will require a variance by the City of Fort Collins. The reasons for requesting/granting this variance are listed below: - The street that is proposed to be 28 feet is a cul-de- sac. - The cul-de-sac will access an arterial street (Shields Street). Given the constraints of the subject property, the primary access must be from Shields Street. The access to Shields Street is proposed to be a right- in/right-out with a deceleration lane on Shields Street. However, it is proposed that there will be alternative access through other properties to the south. - The street will have less than 750 ADT on it. The development itself will have 12 dwelling units, which will generate 120 vehicle trips on an average weekday. The "Fort Collins Senior Center Site Access Study," October 1992, assumed a fast food restaurant on the parcel to south of the Raintree Townhouses PUD. This is likely to be the highest intensity use from a traffic z perspective. This land use will add 470 ADT to the UJ street segment that is just west of Shields Street. z Therefore, the highest traffic volume just west of z Shields Street will be 590 ADT. J - It is proposed that the townhouses would be built on one > side of the street. U Z I recommend that the street in Raintree Townhouses PUD be 28 o feet wide (curb to curb). Given the layout of the Raintree Townhouses PUD site, I recommend on -street parking be allowed 0 only on one side of the street. CL aIf you have any questions or desire additional information, do not hesitate to call me. • U X Sincerel LL Q Q H Matthew J. Delich, P.E.