No preview available
HomeMy WebLinkAboutSPRADLEY BARR AUTO DEALERSHIP PDP FDP - 64 93E - CORRESPONDENCE - STAFF'S PROJECT COMMENTSNo Text No Text REVISION COMMENT SHEET ...... DATE: January 30, 1998 TO: Stormwater PROJECT: #64-93D Spradley Barr Auto Dealrship - Type II (LUC) PDP/FC All comments must be received by Steve Olt no later than the staff review meeting: Wednesday, February 25,1998 It is understood that the drainage report for the site was previously approved by Larimer County. However, the City has the following concerns related to the site drainage design. 1. The site discharges under College Ave. and across a vacant lot to Fossil Creek Although this is the existing condition path of the discharge from the site, the additional impervious area of the site as increased the volume of runoff across the off - site property. It is standard practice for the City to require an off -site drainage easement across this property. The City strongly recommends an off -site drainage easement across this downstream property be provided. 2. The required detention volume calculated in the drainage report appears to be low compared to the City's FAA method. The required volume would need to be the minimum volume of that set by the FAA method to meet City criteria. 3. A portion of the site drains to the property to the south. The rate of runoff appears to be less than existing conditions. However, the discharge location has changed. A letter of agreement would be needed from the south property owner to change the existing character of the off -site drainage. /dAA Date: , - -aE' — e � Signatures%�� cc : /Ni /fe C.etlry AV m CECK HERE 1F YOiJ TO RECEIVE COPIES�JF RENSI Z— PW // ✓D[amage Olhr i — r e„a�* City of Fort Coffins �r ,l 1� ,j. I DATE: January 30, 1998 DEPT: Engineering PROJECT: #64-93D Spradley Barr Auto Dealership - Type II (LUC) PDP/FC PLANNER: Steve Olt ENGINEER: Michael Dean All comments must be received no later than the staff review meeting: Wednesday, February 25, 1998 Dedicate additional Right of Way along South College frontage (approximate )y 12 feet) to the back of sidewalk or dedicate a Public Access Easement at this location. Provide an Easement for the Sanitary Sewer Line. The Final Site Plan and Utility Plan do not match each other. Provide a Safety Rail with 3' setback from the public sidewalk along the retaining wall of the detention ponds to isolate them from the public sidewalk. At cross section A the slope between the top of the retaining wall of the detention pond and the back of sidewalk is steeper than 2:1, provide a recovery strip adjacent to the sidewalk in this location. Drive dimensions do not meet the City of Fort Collins minimum Standard of 24' in width. Drive Access to South College Avenue will require a CDOT Access Permit. The South College Access Control Plan shows this access to be 3/4 movement (Right in/Riot out/Left in) which is not reflected in the design, despite Cityscape Urban Design, Inc. Statement of Planning Objectives letter dated November 14, 1997 stating the access is designed in accordance with the South College Avenue Access Control Plan. This proposed point of access to South College Avenue needs to be redesigned in accordance with CDOT, City of Fort Collins Standards and the South College Access Control Plan. At this time no access permit has been issued by CDOT and should have been required by The Larimer County Engineering Department prior to Utility Plan Approval. The application for the Access Permit will now need to be completed by The City of Fort Collins Engineering Department and approved by CDOT prior to the access approval needed for Certificate of Occupancy. Sheet 4/11 of the Utility Plans was not signed by the Latimer County Engineering Department, this sheet shows the proposed access to South College, this design does not incorporate traffic contra! measures to insure this access functions as a 3/4 movement intersection. Submit a design that is in compliance with the current Standards of CDOT and the City of Fort Collins for this proposed access point. This design will need to be reviewed and approved by The City of Fort Collins prior to application for the CDOT Access Permit. Additional comments will be made when the City of Fort Collins reviews the design. Provide Cross Access with adjacent lots in accordance with the South College Access Control Plan to alleviate problems with 3/4 Movement Access on to South College. ** See redline plans for additional comments ** Date: Z./'Z5 Aa Signature: r Please send copies of marked revisions ✓Plat Site Utility ZLandscape Cih, of Fort Collins /T.I.S. REVISION z COMMENT SHEET DATE: January 30, 1998 TO: Zoning PROJECT: #64-93D Spradley Barr Auto Dealrship - Type II (LUC) PDP/FC All comments must be received by Steve Olt no later than the staff review meeting: Wednesday, February 25,1998 O Ind a: a iy -� o due. 3,a, CI per � � u � ' A . %c�-c� ac&-&cs 0 " . leiPcotN AQiEN d'iiois -M 't'D I�£ 'rxf + C. ID AA4-*-7 3t Ce--j6D r j 4 e_a -b .RC S��G� �14a-E mF Type pro-0 t� �. Cowxro,.sti C 13 is crab S 17-N Pc A-4 At s a S ftc w ^T�r—, 7apo , Date: a T- 4 E- Signature: 6 /A� CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS _ PId _ Sit _ _ Obr (Ma^rIMIM Uffly Rdz VW _ Laws*City of Fort Collins Current Planning Department Steve Olt, ASLA City Planner e) RECYCLED PAPER arm t�roje,vt Cv ry,, meAJ7 v"r`-e-4-� 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 (970) 221-6750 • FAX (970) 221-6378 • TDD (970) 224-6002