Pre -Submittal meetings are offered to assist the designer/builder by assuring, early on in the
design, that the new commercial or multi -family projects are on track to complying with all of
the adopted City codes and Standards listed below. The proposed project should be in the
early to mid -design stage for this meeting to be effective and is typically scheduled after the
Current Planning conceptual review meeting.
Applicants of new commercial or multi -family projects are advised to call 970-416-2341 to
schedule a pre -submittal meeting. Applicants should be prepared to present site plans, floor
plans, and elevations and be able to discuss code issues of occupancy, square footage and
type of construction being proposed.
Construction shall comply with the following adopted codes as amended:
20012 International Building Code (IBC)
2012 International Residential Code (IRC)
20012 International Energy Conservation Code (IECC)
2012 International Mechanical Code (IMC)
2012 International Fuel Gas Code (IFGC)
2012 International Plumbing Code (IPC) as amended by the State of Colorado
2014 National Electrical Code (NEC) as amended by the State of Colorado
Accessibility: State Law CRS 9-5 & ICC/ANSI All 17.1-2009.
Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF.
Frost Depth: 30 inches.
Wind Load: 100- MPH 3 Second Gust Exposure B.
Seismic Design: Category B.
Climate Zone: Zone 5.
Energy Code Use
1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC Chapter 4.
2. Multi -family and Condominiums 3 stories max: 2012 IECC Chapter 4 Residential
Provisions.
3. Commercial and Multi -family 4 stories and taller: 2012 IECC Chapter 4 Commercial
Provisions.
Fort Collins Green Code Amendments effective starting 2/17/2014. A copy of these
requirements can be obtained at the Building Office or contact the above phone number.
City of Fort Collins
Building Services
Plan Review
970-416-2341
Page 10 of 10
11. If this proposal is unable to satisfy any of the requirements so' forth in the LUC, a Modification
of Standard Reque ill need to be submitted with your for. development proposal.
Please see Section c.8.2 of the LUC for more information on criteria to apply for a
Modification of Standard.
12. Please see the Submittal Requirements and Checklist at:
http://www.fcgov.com/developmentreview/applications.php.
13. The request will be subject to the Development Review Fee Schedule that is available in the
Community Development and Neighborhood Services office. The fees are due at the time of
submittal of the required documents for the appropriate development review process by City
staff and affected outside reviewing agencies. Also, the required Transportation Development
Review Fee must be paid at time of submittal.
14. When you are ready to submit your formal plans, please make an appointment with
Community Development and Neighborhood Services at (970)221-6750.
Page 9 of 10
2. Adoption of the 201 ` '-Codes is anticipated for April 4, 2017 ,� advised that permit
applications submit after the code adoption date will be s ,act to the new codes and
standards, as amended.
2.
Planning Services
Contact: Clay Frickey, 970-224-6045, cfrickey(cDfcgov.com
1. A landscape plan will be required as part of this submittal. The landscape plan should show
how you plan to meet the parking interior and perimeter landscape requirements. 6% of the
internal area of the parking lot must be landscaped. You must provide street trees along
Academy Court and provide either a low shrub wall, low fence, earthern berm, or low wall to
provide screening along Academy Court and Prospect Road.
2. You must provide 4 bicycle parking spaces. These spaces can all be provided via fixed rack.
3. The front entrance to the building should have a direct connection to the sidewalk network.
None is shown on the current site plan. Staff will look for this detail upon submittal of a PDP.
4. The parking area must meet the following minimum setbacks:
From an arterial street - 15 feet
From a non -arterial street - 10 feet
From a lot line - 5 feet
5. The maximum parking permitted for your use and the proposed size of the building (5,057
sq. ft.) is 26 spaces (5 spaces per 1,000 sq. ft.). The proposed parking lot exceeds this
requirement. Staff will not support a modification to exceed the parking maximum. Please
revise your site plan to conform to the parking requirements. The minimum parking
requirement is 2 spaces per 1,000 sq. ft., which would equate to 11 spaces.
6. Provide architectural elevations of the trash and recycling enclosure along with the elevations
of the proposed building. The enclosure should use similar architectural features as the
principal structure. The enclosure must be built on a concrete pad and feature a walk-in gate
separate from the main service gates.
7. Per Land Use Code section 4.28(E)(2)(b), the building should be sited to make up 30% of the
frontage along Prospect Rd. Staff can work with you on siting the building to better meet this
standard. Otherwise, this would require a modification that would likely support.
8. The proposed development project is subject to a Type 1 review and public hearing, the
decision maker for Type 1 hearings is an Administrative Hearing Officer. The applicant for
this development request is not required to hold a neighborhood meeting for a Type 1
hearing, but if you would like to have one to notify your neighbors of the proposal, please let
me know and I can help you in setting a date, time and location for a meeting. Neighborhood
Meetings are a great way to get public feedback and avoid potential hiccups that may occur
later in the review process.
9. Please see the Development Review Guide at www.fcgov.com/drg. This online guide
features a color coded flowchart with comprehensive, easy to read information on each step
in the process. This guide includes links to just about every resource you need during
development review.
10. This development proposal will be subject to all applicable standards of the Fort Collins Land
Use Code (LUC), including Article 3 General Development Standards. The entire LUC is
available for your review on the web at http://www.colocode.com/ftcollins/landuse/begin.htm.
Page 8 of 10
11. A Development Cor-`ruction Permit (DCP) will need to be c' ined prior to starting any work
on the site.
12. LCUASS parking setbacks (Figure 19-6) apply and will need to be followed depending on
parking design.
13. All fences, barriers, posts or other encroachments within the public right-of-way are only
permitted upon approval of an encroachment permit. Applications for encroachment permits
shall be made to Engineering Department for review and approval prior to installation.
Encroachment items shall not be shown on the site plan as they may not be approved, need
to be modified or moved, or if the permit is revoked then the site/ landscape plan is in
non-compliance.
14. Any rain gardens within the right-of-way cannot be used to treat the development/ site storm
runoff. We can look at the use of rain gardens to treat street flows — the design standards for
these are still in development.
15. Bike parking required for the project cannot be placed within the right-of-way and if placed
just behind the right-of-way need to be placed so that when bikes are parked they do not
extend into the right-of-way.
16. In regards to construction of this site: the public right-of-way shall not be used for staging or
storage of materials or equipment associated with the Development, nor shall it be used for
parking by any contractors, subcontractors, or other personnel working for or hired by the
Developer to construct the Development. The Developer will need to find a location(s) on
private property to accommodate any necessary Staging and/or parking needs associated
with the completion of the Development. Information on the location(s) of these areas will be
required to be provided to the City as a part of the Development Construction Permit
application.
Department: Electric Engineering
Contact: Coy Althoff, , CAlthoff(a_fcgov.com
1. Light & Power has underground spare 2" and 4" conduits dead -ended at the N.E. corner for
Prospect Rd. and Academy Ct. 3-phase primary power is available in the area.
2. Development charges, electric Capacity Fee, Building Site charges and any system
modification charges necessary will apply to this development.
3. As your project begins to move forward please contact Light and Power Engineering to
coordinate the streetlight, transformer and electric meter locations, please show the
locations on the utility plans.
4. You may contact FCU Light & Power, project engineering if you have questions. (970)
221-6700. You may reference Light & Power's Electric Service Standards at
http://www.fcgov. com/utilities/img/site—specific/uploads/ElectricServiceStandards—FI NAL-17
June20l6.pdf
You may reference our policies, development charge processes, and use our fee estimator
at http://www.fcgov.com/utilities/business/builders-and-developers.
Department: Building Inspection
Contact: Sarah Carter, 970-416-2748, scarter(cDfcgov.com
1. A pre -submittal meeting with Building Services is recommended for this project.
Pre -Submittal meetings assist the designer/builder by assuring, early on in the design, that
the new projects are on track to complying with all of the adopted City codes and Standards
listed below. The proposed project should be in the early to mid -design stage for this meeting
to be effective. Applicants of new projects should email scarter@fcgov.com to schedule a
pre -submittal meeting. Applicants should be prepared to present site plans, floor plans, and
elevations and be able to discuss code issues of occupancy, square footage and type of
construction being proposed.
Page 7 of 10
3) Green Building Program: fcgov.com/enviro/green-building nhp, contact Tony Raeker at
970-416-4238 or tr �r@fcgov.com
4) Solar Energy: www.fcgov.com/solar
5) Integrated Design Assistance Program: http://fcgov.com/idap, contact Gary Schroeder at
970-224-6003 or gschroeder@fcgov.com
6) Nature in the City Program: http://www.fcgov.com/natureinthecity/, contact Justin
Scharton at 970-221-6213 orjscharton@fcgov.com
7) Urban Agriculture: http://www.fcgov.com/urbanagriculture, contact Spencer Branson at
970-224-6086 or sbranson@fcgov.com. In addition, the Northern Colorado Food Cluster is
sponsored and supported by the City of Fort Collins. The executive Director, Brad
Christensen, can be reached at director@nocofoodcluster.org.
Please consider City sustainability goals and ways this development can engage with these
efforts. Let me know if I can help connect you to these programs.
Department: Engineering Development Review
Contact: Katie Andrews, 970-221-6501, kandrews(cDfcgov.com
1. Larimer County Road Impact Fees and Street Oversizing Fees are due at the time of building
permit. Please contact Kyle Lambrecht (klambrecht@fcgov.com) and Dean Klingner
(dklingner@fcgov.com) if you have any questions.
2. The City's Transportation Development Review Fee (TDRF) is due at the time of submittal.
For additional information on these fees, please see:
http://www.fcgov.com/engineering/dev-review.php
3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets,
sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this
project, shall be replaced or restored to City of Fort Collins standards at the Developer's
expense prior to the acceptance of completed improvements and/or prior to the issuance of
the first Certificate of Occupancy.
4. All public sidewalk, driveways and ramps existing or proposed adjacent or within the site
need to meet ADA standards, if they currently do not, they will need to be reconstructed so
that they do meet current ADA standards as a part of this project.
5. Please detach the public sidewalk along Prospect to the intersection of Prospect and
Academy.
6. Any public improvements must be designed and built in accordance with the Larimer County
Urban Area Street Standards (LCUASS). They are available online at:
http://www.larimer.org/engineering/GMARdStds/UrbanSt.htm
7. This project is responsible for dedicating any right-of-way and easements that are necessary
or required by the City for this project. ROW along Prospect will need to be dedicated to the
constrained arterial standard (102' ROW total). Most easements to be dedicated need to be
public easements dedicated to the City. This shall including the standard utility easements
that are to be provided behind the right-of-way (15 foot along an arterial and 9 foot along all
other street classifications). The change in ROW may necessitate additional easement.
Information on the dedication process can be found at:
http://www.fcgov.com/engineering/devrev.php
8. It looks like the proposed accessway is shown to line up with the driveway across Academy
Ct — this looks great and is where the access will need to be to meet LCUASS access
spacing standards.
9. Utility plans will be required and a Development Agreement will be recorded once the project
is finalized.
10. As of January 1, 2015 all development plans are required to be on the NAVD88 vertical
datum. Please make your consultants aware of this, prior to any surveying and/or design
work.
Page 6 of 10
> FCLU 3.4.5(B): If use on the development site may % the use or storage of
hazardous materials kincluding hazardous wastes) on -site, the project shall be designed to
comply with all safety, fire and building codes for the use and storage of the hazardous
materials involved. Adequate precautions shall be taken to protect against negative off -site
impacts of a hazardous materials release, using the best available technology.
7. AST & UST STORAGE TANKS
The installation of Above Ground (AST) or Underground Storage Tanks (UST) require a
separate plan review and permit from the Poudre Fire Authority. Tanks shall be protected
from damage and have secondary containment. All tanks shall be UL listed.
Department: Environmental Planning
Contact: Rebecca Everette, 970-416-2625, reverette(u.fcgov.com
1. Generally, an Ecological Characterization Study (ECS) is required by Section 3.4.1 (D)(1) as
the site is within 500 feet of a known natural habitat (Coterie Natural Area and Spring Creek).
However, as there is an arterial road between those features and this property and the
standard buffer would not extend to this project's parcel, the ECS is waived for this site.
However, please consider the use of native and wildlife -friendly plants and grasses to
complement those natural features, in accordance with Article 3.2.1 (E)(2)(3) of the Land
Use Code.
2. City of Fort Collins Land Use Code [Section 3.2.1 (E)(3)], requires that to the extent
reasonably feasible, all plans be designed to incorporate water conservation materials and
techniques. This includes use of low -water -use plants and grasses in landscaping or
re -landscaping and reducing bluegrass lawns as much as possible.
This site is located within a potential movement corridor for Red -Winged Blackbird and
Painted Lady butterflies. As such, native plants and wildlife -friendly landscaping (e.g.,
flowering perennials, native grasses, fruiting shrubs and trees)and maintenance are also
encouraged. Please refer to the Fort Collins Native Plants document available online and
published by the City of Fort Collins Natural Areas Department for guidance on native plants
is: http://www.fcgov.com/naturalareas/pdf/nativeplants20l3.pdf.
3. In regard to lighting, especially LED light fixtures, cooler color temperatures are harsher at
night and cause more disruption to circadian (biological) rhythms for both humans and
wildlife. Please consider a warmer color temperature (warm white, 3000K or less) for any
LED light fixtures. Please also consider fixtures with dimming capabilities so that light levels
can be adjusted as needed. Site light sources shall be fully shielded and down -directional to
minimize up -light, light spillage and glare [see LUC 3.2.4(D)(3)]. For further information
regarding health effects please see:
http://darksky. org/ama-report-affirms-h uman-health-impacts-from-leds/
4. It is not clear whether there are active prairie dogs on this site. If there are, City Code and the
Land Use Code require that any prairie dogs inhabiting a site must be relocated or humanely
eradicated prior to development activities (see Section 3.4.1(N)(6) of the Land Use Code).
Additionally, should this project gain approval and proceed to construction, a burrowing owl
survey, in accordance with the Division of Parks and Wildlife standards, shall be conducted
prior to construction by a professional, qualified wildlife biologist.
5. Our city has an established identity as a forward -thinking community that cares about the
quality of life it offers its citizens now and generations from now. Thus, the City of Fort Collins
has many sustainability programs and goals that may benefit this project. Of particular
interest may be:
1) ClimateWise program: fcgov.com/climatewise/
2) Zero Waste Plan and the Waste Reduction and Recycling Assistance Program (WRAP):
fcgov.com/recycling/pdf/_20120404_WRAP_ProgramOverview.pdf, contact Caroline Mitchell
at 970-221-6288 or cmtichell@fcgov.com
Page 5 of 10
gpm at 20 psi residual pressure, spaced not further than 300'c�et to the building
3. FIRE LANES
Fire access is required to within 150' of all exterior portions of any building as measured by
an approved route around the perimeter. For the purposes of this section, fire access cannot
be measured from an arterial road (E Prospect Rd) and as such, a fire lane will be needed
on the property. The limits of the fire lane shall allow all exterior portions of the building to be
within 150' of any location in which a fire engine could be positioned. A hammerhead
turnaround will be required.
Any private drive serving as a fire lane shall be dedicated as an Emergency Access
Easement (EAE) and be designed to standard fire lane specifications. If a fire lane cannot
allow full building coverage, the building will require a fire sprinkler system. Code language
and fire lane specifications provided below.
> IFC 503.1.1: Approved fire Lanes shall be provided for every facility, building or portion of a
building hereafter constructed or moved into or within the jurisdiction. The fire apparatus
access road shall comply with the requirements of this section and shall extend to within 150
feet of all portions of the facility and all portions of the exterior walls of the first story of the
building as measured by an approved route around the exterior of the building or facility.
When any portion of the facility or any portion of an exterior wall of the first story of the
building is located more than 150 feet from fire apparatus access, the fire code official is
authorized to increase the dimension if the building is equipped throughout with an approved,
automatic fire -sprinkler system.
4. FIRE LANE SPECIFICATIONS
A fire lane plan shall be submitted for approval prior to installation. In addition to the design
criteria already contained in relevant standards and policies, any new fire lane must meet the
following general requirements:
> Shall be designated on the plat as an Emergency Access Easement.
> Maintain the required 20 foot minimum unobstructed width & 14 foot minimum overhead
clearance.
> Be designed as a flat, hard, all-weather driving surface capable of supporting 40 tons.
> Dead-end fire access roads in excess of 150 feet in length shall be provided with an
approved area for turning around fire apparatus.
> The required turning radii of a fire apparatus access road shall be a minimum of 25 feet
inside and 50 feet outside. Turning radii shall be detailed on submitted plans.
> Be visible by painting and/or signage, and maintained unobstructed at all times. Sign
locations or red curbing should be labeled and detailed on final plans.
> Additional access requirements exist for buildings greater than 30' in height. Refer to
Appendix D of the 2012 IFC or contact PFA for details.
International Fire Code 503.2.3, 503.2.4, 503.2.5, 503.3, 503.4 and Appendix D; FCLUC
3.6.2(B)2006 and Local Amendments.
5. FIRE LANE SIGNS
The limits of the fire lane shall be fully defined. Fire lane sign locations should be indicated on
future plan sets. Code language provided below.
> IFC D103.6: Where required by the fire code official, fire apparatus access roads shall be
marked with permanent NO PARKING - FIRE LANE signs complying with Figure D103.6.
Signs shall have a minimum dimension of 12 inches wide by 18 inches high and have red
letters on a white reflective background. Signs shall be posted on one or both sides of the fire
apparatus road as required by Section D103.6.1 or D103.6.2.
6. HAZARDOUS MATERIALS - GENERAL STANDARD
Combustible liquids along with any other hazardous material, either stored or in use, shall be
identified along with their respective quantities. MSDS sheets are required at time of building
permit. Depending on type and quantities, a HMIA (Hazardous Materials Impact Analysis)
may be requested at time of building permit. Code language provided below.
Page 4 of 10
treatment as described in the Fort Collins Stormwater Manua' Volume 3-Best Management
Practices (BMPs).
(http://www.fcgov.corn/utilities/business/builders-and-developers/development-forms-guideli
nes-regulations/stormwater-criteria) Extended detention is the usual method selected for
water quality treatment; however the use of any of the BMPs is encouraged.
6. Low Impact Development (LID) requirements are required on all new or redeveloping
property which includes sites required to be brought into compliance with the Land Use
Code. These require a higher degree of water quality treatment with one of the two following
options:
a. 50% of the newly added or modified impervious area must be treated by LID techniques
and 25% of new paved areas must be pervious.
b. 75% of all newly added or modified impervious area must be treated by LID techniques.
7. The erosion control report requirements are in Section 1.3.3, Volume 3, Chapter 7 of the Fort
Collins Stormwater Criteria Manual. If you need clarification concerning this section, please
contact the Erosion Control Inspector, Jesse Schlam at 224-6015 or jschlam@fcgov.com.
8. There will be a final site inspection of the stormwater facilities when the project is complete
and the maintenance is handed over to an HOA or another maintenance organization.
Standard operating procedures (SOPs) for on -going maintenance of all onsite drainage
facilities will be included as part of the Development Agreement. More information and links
can be found at:
http://www.fcgov.com/utilities/what-we-do/stormwater/stormwater-quality/low-im pact-develo
pment
9. Per Colorado Revised Statute §37-92-602 (8) effective August 5, 2015, criteria regarding
detention drain time will apply to this project. As part of the drainage design, the engineer will
be required to show compliance with this statute using a standard spreadsheet (available on
request) that will need to be included in the drainage report. Upon completion of the project,
the engineer will also be required to upload the approved spreadsheet onto the Statewide
Compliance Portal. This will apply to any volume based stormwater storage, including
extended detention basins.
10. The 2017 city wide Stormwater development fee (PIF) is $8;217/acre for new impervious
area over 350 square feet and there is a $1,045/acre of site review fee. No fee is charged for
existing impervious area. These fees are to be paid at the time each building permit is
issued. Information on fees can be found at:
http://www.fcgov.com/utilities/business/builders-and-developers/plant-investment-developme
nt-fees or contact our Utility Fee and Rate Specialists at (970) 416-4252 for questions on
fees. There is also an erosion control escrow required before the Development Construction
permit is issued. The amount of the escrow is determined by the design engineer, and is
based on the site disturbance area, cost of the measures, or a minimum amount in
accordance with the Fort Collins Stormwater Manual.
Department: Fire Authority
Contact: Jim Lynxwiler, 970-416-2869, ilynxwiler(@poudre-fire.org
1. FIRE CONTAINMENT
The proposed building is projected to be 4,995 sq. ft. Should the proposed building exceed
5,000 square feet, it shall be sprinklered or fire contained. If containment is used, the
containment construction shall be reviewed and approved by the Poudre Fire Authority prior
to installation.
2. WATER SUPPLY
A hydrant is required within 300' of any Commercial Building as measured along an approved
path of vehicle travel. The existing utility infrastructure available in the area appears to
support this requirement. Code language provided below.
> IFC 507.5 and PFA Policy: COMMERCIAL REQUIREMENTS: Hydrants to provide 1,500
Page 3 of 10
4. Please note that all "'y of Fort Collins Utility Customers are hject to City Code
requirements for w, water. These requirements include 1. ,ion 26-306 Wastewater
Discharge Permit Requirements and Section 26-332 Prohibitive Discharge Standards. A
permit may be required depending on activities on the site; however, discharge standards
apply to every customer, both large and small, regardless of what activities take place on the
site. Please contact Industrial Pretreatment, (970)221-6900, to discuss these requirements
and how they apply to this development.
5. Water conservation standards for landscape and irrigation will apply. Information on these
requirements can be found at: http://www.fcgov.com/standards
6. Development fees and water rights will be due at building permit. These fees are to be paid
at the time each building permit is issued. Information on fees can be found at:
http://www.fcgov. com/uti I ities/business/builders-and-developers/plant-investment-developme
nt-fees or contact our Utility Fee and Rate Specialists at (970) 416-4252 for questions on
fees.
Department: Traffic Operations
Contact: Nicole Hahn, 970-221-6820, nhahn(aD_fcgov.com
1. The anticipated change in traffic volume is not expected to rise to the threshold of needing a
TIS. Based on section 4.2.3.D of LCUASS, the Traffic Impact Study requirement can be
waived.
2. The preliminary site plan shows that the access is aligned with the development across the
street, and this is what we would like to see.
3. A detached side walk along Prospect is preferred.
Department: Technical Services
Contact: Jeff County, 970-221-6588, icountY(ZDfcgov.com
1. As of January 1, 2015 all development plans are required to be on the NAVD88 vertical
datum. Please make your consultants aware of this, prior to any surveying and/or design
work.
2. If submitting a replat for this property/project, addresses are not acceptable in the
Subdivision Plat title/name.
Department: Stormwater Engineering
Contact: Heather McDowell, 970-224-6065, hmcdowell(a)_fcgov.com
1. The design of this site must conform to the drainage basin design of the Spring Creek Master
Drainage Plan as well the Fort Collins Stormwater Criteria Manual.
2. A drainage report and construction plans are required and they must be prepared by a
Professional Engineer registered in the State of Colorado. The drainage report must
address the four -step process for selecting structural BMPs.
3. There is an existing storm pipe (-20-inch RCP) that serves as an outfall pipe for the
properties on the west side of Academy Court and therefore must be maintained in its
current configuration. However, the stormwater outfall from this site may also utilize this
existing outfall pipe. The Plans for the Uplands Prospect Business Park show an alignment
of this pipe that is different than what the City database shows. Please ensure that you have
both the sanitary sewer and storm sewer mains survey located and depths measured to
accurately determine their respective locations and tie-in elevations.
4. Onsite detention is required for the runoff volume difference between the 100-year developed
inflow rate and the 2-year historic release rate.
5. Fifty percent of the site runoff is required to be treated using the standard water quality
Page 2 of 10
r
C ity of loft
Fort C611inb
January 13, 2017
Todd Rand
Baseline Engineering
710 11 th Ave.
Suite 105
Greeley, CO 80631
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov.com
Re: Academy Ct. and Prospect Rd. —Vehicle Minor Repair
Description of project: This is a request to construct a vehicle minor repair facility at the northeast
corner of Academy Court and Prospect Road (parcel #8718413001). The building will be one story and
contain 4,995 sq. ft. of floor area. The proposed site plan shows 30 parking spaces. The site is located
in the Industrial (1) zone district. This proposal will be subject to Administrative (Type 1) review.
Please see the following summary of comments regarding the project request referenced above. The
comments offered informally by staff during the Conceptual Review will assist you in preparing the
detailed components of the project application. Modifications and additions to these comments may be
made at the time of formal review of this project. If you have any questions regarding these comments
or the next steps in the review process, you may contact the individual commenter or direct your
questions through the Project Planner, Clay Frickey, at 970-224-6045 or cfrickey@fcgov.com.
Comment Summary:
Department: Zoning
Contact: Ali van Deutekom, 970-416-2743, avandeutekom(a)fcgov.com
1. LUC 3.5.1 (1) (6) All rooftop mechanical equipment shall be screened from public view by
integrating it into building and roof design to the maximum extent feasible
2. Light sources shall be concealed and fully shielded and shall feature sharp cut-off capability
so as to minimize up -light, spill -light, glare and unnecessary diffusion on adjacent property.
Department: Water -Wastewater Engineering
Contact: Heather McDowell, 970-224-6065, hmcdowell(a)fcgov.com
1. There is an existing 8-inch water main in Academy Court and an existing 12-inch water main
in Prospect Road. There does not appear to be a water stub into this property.
2. The water service and meter for this project site will need to be sized based on the AWWA
M22 manual design procedure. A sizing justification letter that includes demand calculations
for maximum flows and estimated continuous flows will need to be provided as a part of the
final submittal package for this project.
3. There is an existing 8-inch sewer main along the eastern edge of the property. This sewer
main appears to be within an existing 40.5-foot wide utility easement that was dedicated by
the Uplands Prospect Business Park PUD Plat. City records indicate that there are no sewer
service stubs for this property along this length of sewer main.
Page 1 of 10