HomeMy WebLinkAboutCHRISTIAN BROTHERS AUTOMOTIVE - PDP170018 - REPORTS - RECOMMENDATION/REPORT1 inch -
Christian Brothers Automotive
Zoning & Vicinity Map
The City of Fort Collins will make reasonable accommodations for access to City services, programs, and activities and will make special communication
arrangements forpersons with disabilities. Auxiliary aids and services are available forpetsons with disabilities. V/TDD: Dial 711 for Relay Colorado.
Esta es una noticaci6n sobre la reuni6n de su vecindario o sobre una audiencia p6blica sobreel desartnllo o proyecto en la propiedad cetra de donde usted es el
dueno de propiedad. Si usted desea que esta notiftcact6n sea traducida al espanol sin costo alguno, favor enviar un correo electr6nico en espanol a la siguiente
direcci6n electr6nica: translate(afcgov.com.
Staff Report — Christian Brothers Automotive, PDP170018
Administrative Hearing 10-12-2017
Page 11
C. The Project Development Plan complies with relevant standards of Article 3 —
General Development Standards.
D. The Project Development Plan complies with relevant standards located in
Division 4.28 Industrial (1) of Article 4 — Districts.
RECOMMENDATION:
Staff recommends approval of Christian Brothers Automotive, PDP170018.
ATTACHMENTS:
1. Zoning & Site Vicinity Map
2. Christian Brothers Automotive Planning Document Set (Site Plan, Landscape
Plan, Elevations & Photometric Plan)
Staff Report —Christian Brothers Automotive, PDP170018
Administrative Hearing 10-12-2017
Page 10
Non-residential structures are limited to four stories in height. The Project
Development Plan/Final Plan proposes a one-story structure.
C. Section 4.28(E)(2)(b) — Development Standards — Orientation
Buildings shall be sited so that a building face abuts upon the minimum
landscape yard for at least 30% of the building frontage along arterial
streets. 100% of the building face along Prospect Rd. abuts the landscape
yard, which meets this standard.
D. Section 4.28(E)(2)(c) — Development Standards — Building Character and
Color
New building color shades shall be neutral, with a medium or dark color
range, and not white, bright or reflective. The proposed materials are all
neutral and are not white, bright or reflective.
E. Section 4.28(E)(3)(b) — Storage and Operational Areas
Storage, loading and work operations must be screened from view along
district boundary lines and public streets in the I District. The proposed
site plan shows a 6-foot high solid fence surrounding the storage, loading
and work area.
4. Findings of Fact/Conclusion:
In evaluating the request for Christian Brothers Automotive, PDP170018, Staff
makes the following findings of fact:
A. The Project Development Plan complies with the process located in Division 2.2
— Common Development Review Procedures for Development Applications of
Article 2 — Administration.
B. The Modification of Standard to Section 4.28(E)(3)(a)(2) that is proposed with
this Project Development Plan meets the applicable requirements of Section
2.8.2(H), in that the granting of the Modification would not be detrimental to the
public good and the proposal submitted promotes the general purpose of the
code standard equal to or better than would a compliant plan.
Staff Report — Christian Brothers Automotive, PDP170016
Administrative Hearing 10-12-2017
Page 9
N. Section 3.2.5 - Trash and Recycling Enclosures
Trash and recycling enclosures must be provided in locations abutting
refuse collection or storage areas, designed to allow walk-in access
without having to open the main service gate, screened from public view,
and constructed on a concrete pad. The proposed trash and recycling
enclosure design satisfies the standards.
O. Section 3.5.1(E) - Building Materials
All proposed buildings shall use similar materials to existing buildings in
the neighborhood or use similar architectural characteristics if dissimilar
materials are proposed. Christian Brothers proposes a building with a
predominantly brick and stone fagade. Most of the other buildings in the
area are built out of stucco, corrugated metal, and concrete masonry units.
The proposed materials for Christian Brothers exceeds the quality of the
other buildings in the area, meeting this standard.
P. Section 3.5.1(1) - Outdoor Storage Areas/Mechanical Equipment
The proposed plan is consistent with the requirements of the Land Use
Code in regards to the location of outdoor storage, screening of storage
areas, and screening of rooftop mechanical equipment from public view.
Q. Section 3.6.6 — Emergency Access
For the Christian Brothers Automotive site, an emergency access
easement is proposed that runs through the access drive on the north side
of the site. This satisfies the requirements for the Poudre Fire Authority.
4. Compliance with Article 4 of the Land Use Code — Industrial (1), Division
4.28:
The project complies with all applicable Article 4 standards as follows:
A. Section 4.28(B)(2) — Permitted Uses
The proposed uses, office and vehicle minor repair, are permitted in the
Industrial zone district and are consistent with the district's intent to
provide a wide range of commercial and industrial operations.
B. Section 4.28(D)(1) — Dimensional Standards
Staff Report — Christian Brothers Automotive, PDP170018
Administrative Hearing 10-12-2017
Page 8
The proposed parking lot layout is consistent with requirements of the
Land Use Code in regards to circulation routes, orientation, landscaped
islands, and points of conflict.
Section 3.2.2(J) - Setbacks
The proposed parking lot is setback further than the 15-foot minimum from
an arterial street,10-foot minimum from non -arterial streets, and 5-foot
minimum along a lot line required per the Land Use Code.
J. Section 3.2.2(K)(2) — Nonresidential Parking Requirements
Vehicle service and maintenance uses must provide a minimum of 2
spaces per 1,000 square feet and a maximum of 5 spaces per 1,000
square feet. For a 5,104 square foot building, this results in a minimum of
10 spaces and maximum of 25 spaces. This code section allows a 20%
increase to the maximum parking ratio if there is no on -street parking
available adjacent to the property. Neither Prospect Rd. nor Academy Ct.
have on -street parking. This means the maximum parking for this project
is 30 spaces. The proposed site plan shows 26 spaces, which meets the
standard.
K. Section 3.2.2(K)(5) - Handicap Parking
Parking lots with 26-50 spaces must provide at least 2 handicap parking
spaces with one van accessible with an 8' access aisle. The parking lot
proposed contains two handicap accessible spaces with one van
accessible.
L. Section 3.2.3 - Solar Access, Orientation, Shading
All developments must be designed to accommodate active and/or
passive solar installations and must not deny adjacent properties access
to sunshine. The proposed building is designed and located to minimize
the casting of shadows on adjacent properties and could accommodate
future active and/or passive solar installations.
M. Section 3.2.4 - Site Lighting
The proposed lighting plan is consistent with the requirements of the Land
Use Code in regards to the general standard, lighting levels, and design
standards.
Staff Report —Christian Brothers Automotive, PDP170018
Administrative Hearing 10-12-2017
Page 7
the parking area along Academy Ct. that provide screening from the shine
of vehicle headlights. The parking area is flanked by canopy shade trees
that provide ample tree cover for the perimeter of the parking lot, meeting
this code standard.
D. Section 3.2.1(E)(5) — Parking Lot Interior Landscaping
6% of the interior space of all parking lots with less than 100 spaces shall
consist of landscaping. The parking area has bulb outs at the north end
with evergreen shrubs and a canopy shade tree, which satisfies this code
requirement.
E. Section 3.2.2(C)(4)(b) - Bicycle Parking Space Requirements
The minimum number of bicycle parking spaces required for the vehicle
servicing and maintenance use is four spaces. All of the bicycle parking
spaces may be provided via fixed racks. The applicant proposes four
spaces via fixed rack in accordance with the standard.
F. Section 3.2.2(C)(5) - Walkways
Walkways must be provided to link sidewalks with building entries through
parking lots. These walkways must also provide direct connections to off -
site pedestrian and bicycle destinations. Christian Brothers Automotive
provides a connecting walkway that connects the front door to the
sidewalk along Prospect Rd. in accordance with the standard.
G. Section 3.2.2(D)(1) - Access and Parking Lot Requirements;
Pedestrian/Vehicle Separation
To the maximum extent feasible, pedestrians and vehicles shall be
separated through provision of a sidewalk or walkway. Where complete
separation of pedestrian and vehicles is not feasible, potential hazards
shall be minimized by using landscaping, bollards, special paving, lighting,
and other means to clearly delineate pedestrian areas. Christian Brothers
Automotive separates pedestrians from vehicles by providing a sidewalk
separated from the driving and parking area via curb.
H. Section 3.2.2(E) - Parking Lot Layout
Staff Report —Christian Brothers Automotive, PDP170018
Administrative Hearing 10-12-2017
Page 6
Prospect Road. This level of landscaping provides ample screening and meets
the intent of this code section. The proposed building also uses high -quality
materials that exceed the Land Use Code. The proposed use, vehicle minor
repair, servicing and maintenance establishments, is not an industrial use.
Vehicle minor repair, servicing and maintenance establishments may locate in
five other zone distrcits within the City. In commercial zones, a facility such as
this would not need a 30-foot buffer yard. This buffer yard standard did not
contemplate a use such as this. Due to the enhanced landscaping, high quality
building design, and type of use staff finds this proposal equal to or better than a
compliant plan.
3. Compliance with Article 3 of the Land Use Code — General Development
Standards:
The project complies with all applicable General Development Standards as
follows:
A. Section 3.2.1(D) — Tree Planting Standards
All developments shall establish groves and belts of trees along all city
streets, in and around parking lots, and in all landscape areas that are
located within 50' of any building or structure in order to establish at least
a partial urban tree canopy. The proposed landscape plan shows street
trees planted at appropriate intervals, canopy shade trees planted in
bulbouts adjacent to parking lots, and ornamental trees planted close to
buildings to provide screening and a partial urban tree canopy, which
meets this code standard.
B. Section 3.2. 1 (E)(3)(b)(2) — Water Budget
Annual water use shall not exceed 15 gallons/square foot over the site.
The water budget shown on the landscape plan indicates the landscape
area will require 2.01 gallons/square foot, in accordance with this
standard.
C. Section 3.2.1(E)(4) — Parking Lot Perimeter Landscaping
The perimeter of parking lots are required to have trees planted at a ratio
of 1 per 25 lineal feet along a public street and 1 per 40 lineal feet along a
side lot line and parking setback area. Parking lots must also have
screening to block at least 75% of light from vehicle headlights. The
proposed landscape plan shows shrub beds extending the full length of
Staff Report — Christian Brothers Automotive, PDP170018
Administrative Hearing 10-12-2017
Page 5
or physical conditions which hinder the owner's ability to install a solar energy
system, the strict application of the standard sought to be modified would result
in unusual and exceptional practical difficulties, or exceptional or undue hardship
upon the owner of such property, provided that such difficulties or hardship are
not caused by the act or omission of the applicant; or
(4) the plan as submitted will not diverge from the standards of the Land Use
Code that are authorized by this Division to be modified except in a nominal,
inconsequential way when considered from the perspective of the entire
development plan, and will continue to advance the purposes of the Land Use
Code as contained in Section 1.2.2.
Any finding made under subparagraph (1), (2), (3) or (4) above shall be
supported by specific findings showing how the plan, as submitted, meets the
requirements and criteria of said subparagraph (1), (2), (3) or (4).
Applicant's Justification for the Modification:
We propose a 25-foot buffer yard between the building and Prospect. Within the
buffer, we are providing enhanced landscaping. The design of the building
exceeds the standards in the zone so the need to buffer is reduced.
Staff Finding:
Staff finds that the request for a Modification of Standard to Section
4.28(E)(3)(a)(2) is justified by the applicable standards in 2.8.2(H)(1).
A. The granting of the Modification would not be detrimental to the public good
B. The project design satisfies 2.8.2(H)(1): the plan as submitted will promote
the general purpose of the standard for which the modification is requested
equally well or better than would a plan which complies with the standard for
which a modification is requested.
The purpose of this standard is to screen industrial buildings from arterial streets.
Most industrial buildings typically have little visual interest and so the landscape
buffer yard provides a buffer between the street and low -interest industrial
buildings. Since the plan does not comply with Section 3.5.3 of the Land Use
Code by virtue of having a parking lot between the building and the Academy Ct.
right-of-way, this standard applies.
Instead of the standard 30-foot buffer yard, the applicant proposes a 25-foot-wide
buffer yard between the building and Prospect Rd. A series of Mugo Pines,
Honeylocust trees, and Tiny Wine Ninebark shrubs screen the building from
Staff Report - Christian Brothers Automotive, PDP170018
Administrative Hearing 10-12-2017
Page 4
2. Compliance with Section 2.8.2(H) of the Land Use Code - Modification of
Standards
Modification Description:
The applicant requests a modification to Section 4.28(E)(3)(a)(2) — Site Design —
Screening to provide less than a 30-foot-deep landscape buffer yard along
Prospect Rd.
Land Use Code Standard Proposed to be Modified (areas underlined and
bolded for emphasis):
Land Use Code 4.28(E)(3)(a)(2):
A minimum thirtV-foot deep landscaped yard shall be provided
along all arterial streets, and along any district boundary line that
does not adjoin a residential land use. If a district boundary line
abuts upon or is within a street right-of-way, then the required
landscaped yard shall commence at the street right-of-way line on
the district side of the street, rather than at the district boundary
line. This requirement shall not apply to development plans that
comply with the standards contained in Section 3.5.3 of this Code.
Land Use Code Modification Criteria:
"The decision maker may grant a modification of standards only if it finds that the
granting of the modification would not be detrimental to the public good, and that:
(1) the plan as submitted will promote the general purpose of the standard for
which the modification is requested equally well or better than would a plan which
complies with the standard for which a modification is requested; or
(2) the granting of a modification from the strict application of any standard
would, without impairing the intent and purpose of this Land Use Code,
substantially alleviate an existing, defined and described problem of city-wide
concern or would result in a substantial benefit to the city by reason of the fact
that the proposed project would substantially address an important community
need specifically and expressly defined and described in the city's
Comprehensive Plan or in an adopted policy, ordinance or resolution of the City
Council, and the strict application of such a standard would render the project
practically infeasible; or
(3) by reason of exceptional physical conditions or other extraordinary and
exceptional situations, unique to such property, including, but not limited to,
physical conditions such as exceptional narrowness, shallowness or topography,
Staff Report — Christian Brothers Automotive, PDP170018
Administrative Hearing 10-12-2017
Page 3
ure is unnstian tirotners Automotive coninq & wie vi
s c rrr�
Christian Brothers Automotive
Zoning & Vicinity Map -i-
Staff Report — Christian Brothers Automotive, PDP170018
Administrative Hearing 10-12-2017
Page 2
public good and the proposal submitted promotes the general purpose of the
code standard equal to or better than would a compliant plan.
• The Project Development Plan complies with relevant standards of Article 3 —
General Development Standards.
• The Project Development Plan complies with
Division 4.28 Industrial (1) of Article 4 — Districts
4.28(E)(3)(a)(2) is approved.
COMMENTS:
Background
relevant standards located in
, assuming the modification to
The property annexed into the City as part of the Upland Annex in April, 1984. The lot
was platted as part of the Upland Prospect Business Park PUD Replat in 1994. The lot
has sat vacant since.
The surrounding zoning and land uses are as follows:
Direction
Zone District
Existing Land Uses
North
Industrial (1), Public Open Lands POL
Railroad right-of-way, Kingfisher Natural Area
South
Industrial (1)
Coterie Natural Area
East
Employment (E)
Retail
West
Industrial (1), Employment (E)
Railroad right-of-way, school, office
A zoning and site vicinity map is presented on the following page.
F6rt of
ITEM NO
MEETING DATE
STAFF
1
Oct. 12, 2017
Clay Frickey
ADMINISTRATIVE HEARING OFFICER
PROJECT: Christian Brotherd Automotive, PDP170018
APPLICANT: Todd Rand
Baseline Engineering
4007 S Lincoln Ave.
Suie 405
Loveland CO. 80537
OWNERS: Academy Court Enterprise LLC
5412 Vardon Way
Fort Collins, CO 80528
PROJECT DESCRIPTION:
This is a request for a Project Development Plan to construct a vehicle minor repair,
servicing and maintenance establishment at the northeast corner of Academy Court and
Prospect Road (parcel #8718413001). The building will be one-story and contain 5,140
sq. ft. of floor area. The proposed site plan shows 26 parking spaces. The site is located
in the Industrial (1) zone district .
RECOMMENDATION: Staff recommends approval of Christian Brothers Automotive,
PDP170018.
EXECUTIVE SUMMARY:
Staff finds the proposed Christian Brothers Automotive Project Development Plan
complies with the applicable requirements of the City of Fort Collins Land Use Code
(LUC), more specifically:
• The Project Development Plan complies with the process located in Division 2.2
- Common Development Review Procedures for Development Applications of
Article 2 - Administration.
• The Modification of Standard to Section 4.28(E)(3)(a)(2) that is proposed with
this Project Development Plan meets the applicable requirements of Section
2.8.2(H), in that the granting of the Modification would not be detrimental to the
Planning Services 281 N College Ave - PO Box 580 - Fort Collins, CO 80522-0580
fcgov.com/developmentreview/ 970.221.6750