Loading...
HomeMy WebLinkAboutWINDTRAIL APARTMENTS PUD PRELIMINARY - 66 93D - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSVI. RECOMMENDATIONS This study assessed the transportation impacts of the continued development of CAT and Windtrail, located east of Shields Street and between Prospect Road and Drake Road in Fort Collins, Colorado. Currently, the key signalized intersections operate acceptably. The unsignalized intersections operate acceptably,. ''except for minor street left turns during the afternoon peak hour at the intersections along Shields Street. With full development of CAT and Windtrail, the unsignalized intersections will operate acceptably, except for minor street left turns at some intersections along Shields Street. This type of operation is normal along arterial streets. It is expected that the Shields/Rolland Moore and Drake/Worthington intersections will warrant signalization in the future. Key signalized intersections will generally operate acceptably with geometric improvements. The location of these properties within Fort Collins provides opportunities for high transit and bicycle .usage. The long standing connection between Shields Street and Centre Avenue via Rolland Moore Drive has circulation benefits to both the neighborhood and CAT tenants, as well as .the city in general. Both the developers and the neighborhood desire not to have this connection. There are no technical reasons why this connection should not be made. 16 � � N 1 1 PROSPECT /� W R F- Z W U N G J W N W MOORE"'CENTRE 1 D O U ....,.e. �..... 'Ili—onAxe'�l� MEADOWLARK LONG RANGE GEOMETRIES Figure 6 Table 3 Future Peak Hour Operation (With Geometrics Shown in Figure 6) Level of Service Intersection AM PM College/Prospect (signal) C D College/Drake (signal) C D Drake/Meadowlark/Research (signal) B B Drake/Worthington (signal) B C Drake/Shields (signal) C C Shields/Centre/Raintree (signal) B C Shields/Rolland Moore (signal) B C Shields/Hill Pond (stop sign) EB LT/T/RT D E WB LT/T/RT E E SB LT B C NB LT B C Shields/Prospect (signal) C E Prospect/Centre (signal) B B 14 Table 2 Current Peak Hour Operation Level of Service Intersection AM PM College/Prospect (signal) C C College/Drake (signal) B C Drake/Meadowlark/Research (signal) B. B Drake/Worthington (stop sign) NB LT/RT A B WB LT A A Drake/Shields (signal) C C Shields/Centre/Raintree (signal) B B Shields/Rolland Moore (stop sign) EB LT E E EB RT A A NB LT A B Shields/Hill Pond (stop sign) EB LT/T/RT D E WB LT/T/RT C D SB LT A A NB LT A B Shields/Prospect (signal) B C Prospect/Centre (signal) B B 13 Centre Avenue will be a collector street that will connect Shields Street to Prospect Road. It will also connect to Drake Road via Research Boulevard. The neighborhood (Windtrail, Sundering, Hill Pond) will benefit by not creating an enclave with only access to an arterial street (Shields). This connection will remove some traffic from some arterial/arterial intersections that will experience operational problems. While there will likely be some traffic utilizing this connection which the neighborhood will label as undesirable, this traffic will be small in volume due to the circuitous nature of the connection. Conversely, the connection may benefit CSURF and its expected tenants by providing a second access to Shields Street. With the connection, it is expected that Rolland Moore drive will carry 3000-4000 vehicles per day on the segment closest to Shields Street. At a point 400 feet east of Shields Street, Shire Way intersects from the north and a shared loop driveway intersects from the south. The 3000-4000 daily traffic will decrease rather dramatically at this location. It is recommended that the 400 foot segment east of Shields Street have a collector level cross section. However, east of Shire Way, Rolland Moore Drive will .function as a local street and should, therefore, have a local street cross section. The neighborhood contends that this connection will be -a convenient route for park users and others desiring a short cut. The fact is, that if the connection is made, some of this will occur. Assuming that the overall CAT project is desirable for this area, in particular, and the City of Fort Collins as a whole, then the issue of the road connection should have no bearing on the desirability of the CAT or Windtrail developments. I I 4 I I 12 I V. TRANSPORTATION IMPACTS The key intersections were analyzed using the unsignalized and signalized analysis techniques as published in the "Highway Capacity Manual," Special Report 209, TRB, 1985. Table 2 shows the level of service analysis, using the currently available morning and afternoon peak hour traffic at key intersections. Calculation forms are provided in Appendix B. The key intersections currently operate acceptably, except for minor street left turns at stop sign controlled intersections along Shields Street. Acceptable ,operation is defined as level of service D or better. The delay associated with level of service E operation during the afternoon peak hour is common and is generally accepted at stop sign controlled intersections on arterial streets in urban areas. It is expected that traffic signals will be warranted at the Shields/Rolland Moore and Drake/Worthington intersections in the future. The Shields/Rolland Moore signal will likely be warranted in a relatively short period of time, given the development activity in Parcel J. Table 3 shows the level of service at the key intersections. Calculation forms are provided in Appendix C. Acceptable operation can generally be achieved. Figure 6 shows the geometrics necessary at each intersection to -achieve the levels of service indicated in Table 3. The geometrics shown at some intersections may be beyond that which. is considered to be practicable. However, this central area of Fort Collins is the best area for utilizing alternative modes (transit and bicycle), particularly for work trips. Therefore, the Figure 6 geometrics may not be required if some travel reductions can be realized .for CAT and in Fort Collins, in general. 1 Rolland Moore Drive I The developers of the north portion of CAT (CSURF) and Windtrail ' (John McCoy) desire not to have Rolland Moore Drive connect to Centre Avenue through Parcel J. This connection has been shown on all previous CAT plans. However., deleting the connection is in response to neighborhood concerns and the desire of the developers to not mix commercial and residential traffic. A sensitivity analyses was performed with and without this access. From a purely technical basis, provision of this access will not significantly affect the operation at any key intersection in the vicinity of CAT. This connection between Shields Street and Centre Avenue has always been considered to be a minor connection, not intending to carry high traffic volumes. However, the connection has benefits to both the neighborhood (present and future) and CSURF. 11 I o 0 0 O O O O N 7 O O � coN 1C N[V "7 �- 170/300\\ 70/60 0 0 o$ ,n o 0 0 0 Ln ,n 230/110 co °c �- 300/760 ` ^ Y f 470/1030 "' Q' ^ f- 430 830 �160/450 PROSPECT + 210/110 � + l_ r- 220/300 250/140 - 130/50 --y) } r 280/270 ----)e } 800/400 0 0 0 900/850 — an o 0 730/700 — O 120/110"-� C14�� 90/50-� c LO c 250/380 ZZ t�&onn W mot` now Q nrn^ ub W N\� U c m c 50/30 r - NOM. r- 20/15 10/30 f r HILL POND LEGEND: NOM. o o AM / PM 20/20 —11� o o Rounded to nearest 6 vehicles. o tr LO 1co SHIELDS W �^In 95/80 C.9. 'n LO NOM. w .� r-95/75 J O LLAND 0 MOMS } r MOORE "CE NTAE W 5/65 -� , c H n � m Z coo o Q �oa c 85/340 OZ mom f10/10 % 25/100 _ 75/95 } CENTRE = t 100� w 0/8 3/0�O W Y� a o O M N O^ O O N o o N \\ t'7 tOo \ \\\ 5616 0 10 0 180/400 I0 l0 ,--140/200 0 10_ o_ �_ 260/190 I� 1� o 200/150 1 /r- 90/300 0! 1 %-15/80510 J 1 % 25/995 00 /� 1 /� 170/ 80 300/160 } r 90/120 } r 145/50 -1 } r 300/330 - } 800/650 g o om 1160/980 -� o o,� n 1130/1230 N n g 550/650 -� o 0 0 340/260 n to 15/45 �\\ 25/30 200/500 g 23 N roN C4"Cm Nto C" pOn ^ N C4 MEADOWLARK FUTURE PEAK HOUR TRAFFIC CENTRE FOR ADVANCED TECHNOLOGY BUILDOUT Figure 5 ■ L92 ,In� r o 130/275 \� Cc U-) = 250/623 ^ cn' J j �— 134/465 PROSPECT 211/114—r 1 j 740/347 r, mo 87/68 co� C,J cc rl 1992 qd- c — 30/18 c' f- 0/1 13/8 5/13 --/ ) f r HILL POND 0/0 - o rn 7/6� r^.,�n C rn Ln co 117/45 —r 653/560 49/34 -� 1989 m V 0 L65/ 163, 3345862 i _� 326/51 --17/17 1 �,-155/253 } 192/154 N m up539/413 -� r, uo pi M N � 191/332 nn` CN ' n 1993 NL^ LEGEND: AM / PM yi SHIELDS W �Lo c7 ROLLAND�' ;tMES'ZED MOORE 993 O 5/35 U 5/65 o "CENTRE N N W W Lo co F- ^ Ln 1992 Z L �^ 1 Q �� � 5132 l� GO u7 f- 2 5 / 1 %— 7/19 20/461 1 1 I ..�....,� ` - 17—� 2 16 — � W3 r ornN , N 1989 1987 W to aWC W s o� �1992 Lo CIO �� Q �148/337 �� — 62/118 Q ��Lo G M v N 178/732 278/1185 304/1178 o � aD CO. 169/129 +— 293/536 52/165 r-11/77 J + /—23/92 � + r-140/153 f re 901 680 / I 27/17 } 266/244 } 263/131� 576/478 + 1 12/42 Ln n N rn w 817/647 —� •n rn to 429/424 —� w n r; 288/216 N M Z n 25/27 —� to rnfn 129/331 crl O ^^ Z MEADOWLARK RECENT PEAK HOUR TRAFFIC Figure 4 I I I IV. TRAFFIC VOLUMES AND TRIP ASSIGNMENT Morning and afternoon peak hour traffic counts were obtained at the key intersections as shown in Figure 4. Raw count data is provided in Appendix A. Trip Assignment The trip assignment is the product of the trip generation and trip distribution process. Only a long range trip assignment was performed, since historic development of CAT has not followed an established phasing program. In the past, development has been "market driven." Figure 5 shows the long range trip assignment assuming full build out of the subject properties. Background traffic was obtained from review of City of Fort Collins transportation planning forecasts and of historic trends in this area of Fort Collins. Since CAT can be defined as an "in fill" development, much of the traffic shown in Figure 5 will occur regardless of the level of development of CAT. 8 H W W Q F 5% y co 0 J W co 10% Vol Lo PROSPECT ROAD CENTRE � /r Mvnu Lol I TRIP DISTRIBUTION 10% 10% Figure 3 i III. TRIP DISTRIBUTION The overall directional distribution of the site generated traffic was based upon the existing travel patterns and taken from other traffic studies in this area of Fort Collins. Also considered in the trip distribution was trip productions in Fort Collins. Typical trip productions for employment and retail centers are residence locations. Trip distribution was developed and rounded to the nearest 5 percent as shown in Figure 3, Cj 9 Table 1 (Cont.) Trip Generation Daily A.M. Peak P.M. Peak Land Use Trips Trips Trips Trips Trips. in out in out N. Elderly Housing (Developed) P. Residential - New Mercer 310 14 8 6 18 Commons Q. Industrial/Office 210 27 5 5 24 (N.T.U.) R. Retail 6700 50 40 320 325 S. Industrial/Office/ 3940 153 43 168 295 Retail T. Industrial/Office/R&D 980 115 18 23 113 U. Industrial/Office/R&D 660 85� 14 16 76 V. Retail/Auto Related 2700 46 13 50 89 N. Commercial/Office/ 2000 64 19 87 115 Auto Related X. Financial/Office/R&D - - - - - (Developed) 5 I II. TRIP GENERATION Trip generation was estimated using Trip Generation, 5th Edition, ITE. Table 1 shows the daily and peak hour trip generation for the various uses within these developments. A trip is defined as a one way vehicle movement from origin to destination. The origin or destination of a generated trip would be within the proposed developments. The trip generation shown in Table 1 is for those portions of CAT which are currently either under construction of vacant. Land Use A. Open Space/Recreation B. Open Space/Recreation C. Open Space/Recreation E. Open Space/Recreation F. Open Space/Recreation G. Transitional H. Industrial/Office/R&D I. Industrial/Office/R&D J. Residential - SF DU - MF DU Ja. Residential K. Industrial/Office/R&D L. Industrial/Office/R&D M. Office Table 1 Trip Generation Daily Trips 40 20 20 50 50 170 1570 910 200 370 1240 1445 780 320 4 A.M. Peak Trips Trips in out 6 4 3 2 2 2 8 6 8 5 18 4 198 .33 115 19 4 12 5 21 25 71 182 31 98 17 39 5 P.M. Peak Trips Trips in out 5 8 2 4 2 3 8 12 7 11 5 18 37 179 21 104 14 7 21 11 86 45 34 165 18' 89 7 35 COLORADO STATE UNIVERSITY PROSPECT ROAD II 3"rm FUTURE SIGNALIZED RAINTREE A* N NO SCALF SITE PLAN Figure 2 SITE LOCATION Figure I I. INTRODUCTION This traffic study for the Centre for Advanced Technology (CAT) and Windtrail developments addresses the capacity, geometric, and traffic control requirements associated with the proposed residential, business park, and commercial uses, located in the square mile bordered by Drake Road, Shields Street, Prospect Street, and College Avenue in Fort Collins, Colorado. The site location is shown in Figure 1. This report serves as an update for the "Centre for Advanced Technology Site Access Study," January 1990. This update was precipitated by a land trade between the Colorado State University Research Foundation (CSURF) and John McCoy (developer of Windtrail). As part of the land trade, both CSURF and John McCoy desired not to provide vehicular access between Parcel J and proposed Centre Avenue. City staff requested the update study due to the land use trade and street system change. IExisting and Proposed Site Uses The land for these developments is currently in various stages of development. Figure 2. shows a site plan of the CAT and Windtrail properties. The south portion of CAT (parcels K through X) is being developed by Everitt Enterprises. This portion has experienced steady development since the mid 19801s. The north portion of CAT (parcels A through J) is being developed by CSURF. The land trade proposed expanding Parcel H and a portion of Parcel J (labelled as Ja in Figure 2) into the Windtrail area. The portion of Parcel J that is adjacent to Shields Street would be developed by John McCoy as various residential uses. Site Access Access is proposed via existing and new streets. Figure 2 also shows the primary streets that will access CAT. The CAT development accesses the arterial street system via Shields Street and Drake -Road. Figure 2 also shows that Centre Avenue will be extended to Prospect Road when, development occurs in the north portion of CAT. Existing Land Uses Land uses in the vicinity of CAT and Windtrail are predominantly residential, institutional, commercial, and recreational. Rolland Moore Park and Raintree Shopping Center are west of CAT. There is residential land north and south of CAT. Colorado State University (CSU) is north of Prospect Road. The CSU Veterinary Teaching Hospital is east of CAT. CENTRE FOR ADVANCED TECHNOLOGY SITE ACCESS STUDY FORT COLLINS, COLORADO MAY 1994 Prepared for: Colorado State University Research Foundation P.O. Box 483 Fort Collins, CO 80522 Prepared by: MATTHEW J. DELICH, P.E. 3413 Banyan Avenue Loveland, CO 80538 Phone: 303-669-2061 37. What are the price ranges of the single family patio homes? RESPONSE: Prices will range from $110,000 to 130,000 for the patio homes. These homes will range in size from 1,200 square feet to 1,600 square feet and feature two -car garages. 0 without impacting the existing residences on Hill Pond Road. CSURF will be right in the thick of things and they need to participate in street improvements as needed, not in the distant future. There needs to be a commitment to build the street network out to Shields before any further development is approved in this area 28. Don't make Hill Pond a direct connection to Centre Avenue. 29. Can CSURF commit to a street pattern? RESPONSE: Yes, we can commit to a street pattern but we cannot commit to a timeframe since we have no end user for our portion of the land trade. 30. When will there be a commitment on the street network? RESPONSE: Prior to P & Z. 31. This area needs a collector street to relieve potential pressure on Hill Pond Road. RESPONSE: This is a good comment. 32. What about construction traffic for the portion of Windtrail that is already approved? Can construction traffic be routed through Tract J on a temporary road and not impact Hill Pond Road? RESPONSE: This will be investigated. 33. What will trigger Centre Avenue to be built over to Prospect? RESPONSE: It is difficult to guess what would trigger this street extension. Perhaps the construction of a U.S.D.A. facility in the C.A.T. would trigger the extension. 34. Would Windtrail Limited Liability (McCoy) build the single family or would a different builder? RESPONSE: McCoy would build the single family which are actually more of a patio home product. 35. Is single family feasible south of Rolland Moore Drive next to the slope? RESPONSE: Yes, these lots will be for patio homes. 36. Will there be major grade changes? RESPONSE: No, there will be minor grade changes to accomplish proper drainage. 5 closer to the main campus. At this time, we are doing due diligence on the pros and cons. We are hopeful the trade will occur. The decision will have to be made by our Board of Directors. 23. What does CSURF anticipate doing with the property gained from Windtrail? RESPONSE: We plan on holding the land until a user is identified that promotes the affiliiation between CSU and private sector research. On the O.D.P., we presently call this out to be office, commercial, and research & development. An example would be Summit Labs, the biotech company that just completed a building in the C.A.T. There are no end users identified at this time. We are in a position to hold the land without the pressure to develop so we can hold for the long term. 24. The Bay Farm portion of the C.A.T. is about 40 acres in size. This area is absolutely critical in preserving neighborhood compatibility. This area is designated as passive open space and or recreation. As property owners, we are expecting these areas to remain so designated. CSURF should be informed that any proposed changes to these parcels requires the full amendment process with a hearing in front of the P & Z Board. RESPONSE: CSURF has no plans to change the existing designations on the approved C.A.T. Overall Development Plan. 25. We are concerned about the traffic on the CSURF portion of the trade. Hill Pond Road should not be expected to continue straight through to Centre Avenue. This will bring too much traffic into our neighborhood and the street is too narrow as is. Any extension of Hill Pond Road must be carefully considered so it fits into the big picture. RESPONSE: This is a good comment. 26. We prefer that CSURF traffic be kept separate from Hill Pond and Windtrail traffic. CSURF traffic should be directed over to Centre Avenue and Hill Pond/Windtrail traffic should be directed over to Shields. Rolland Moore Drive should not be a collector street that ties directly into Centre Avenue. RESPONSE: Again, this is a good comment. 27. If'Windtrail townhomes and single family have a hope of tieing into Shields via Rolland Moore Drive, then the street will have to cut across CSURF's portion of the land trade. This will require that CSURF participate in the construction. I am concerned about getting a commitment from CSURF as to their willingness to participate. We must have a way for these folks to get to Shields 4 regular traffic from moving through. The Poudre Fire Authority has jurisdiction over the final design. 15. We are concerned. that the fire access lane not become a parking lot. RESPONSE: That is our concern also. 16. Will there be access from Hill Pond Road to Rolland Moore Drive? RESPONSE: Yes, a connection is anticipated via Shire Court. 17. Will there be a traffic signal on Shields? RESPONSE: Yes, eventually, there will be a signal at Shields and Rolland Moore Drive. The timing of installing the signal is not clear at this time due to funding sources. Usually, the need must be clearly warranted before funding is available for a new signal. 18. A signal on Shields at Rolland Moore Drive is needed now, even if this project does not go forward. The City installed a signal at Horsetooth Road and Manahattan Drive where the need is dubious. The lack of need did not prevent a signal from being installed there. 19. Windtrail Townhomes and single family, (north of Tract J and previously approved) need an outlet other than Hill Pond Road. Rolland Moore Drive needs to be a second point of access so Hill Pond Road does not get loaded up. This will require participation from CSURF. RESPONSE: This is a good comment. As you are aware, Windtrail Limited Liability Company is working cooperatively with CSURF on a potential land trade. This cooperative effort recognizes the need to coordinate circulation in the area. 20. When do you expect to break ground? RESPONSE: We expect to begin land development work in the Fall, depending on when and if we obtain H.U.D. guarantees. Construction of the apartments could take up to one year to complete. 21. When will the trade with CSURF become official? RESPONSE: We hope by this summer. 22. What is CSURF's position on the land trade? RESPONSE: We are looking favorably at the trade since it gives us more land closer to the future Centre Avenue. This will tie us 3 6. Is there any H.U.D. participation? RESPONSE: Yes, the program is referred to as 2-21-D-4. This program involves a guaranteed mortgage, not subsidized housing. 7. Will this project trigger the vacation of the Shields/Shire intersection? RESPONSE: Yes, in accordance with the Sundering Townhome P.U.D. approved back in 1982. 8. Will the units be air conditioned? RESPONSE: Yes. 9. Will the units be handicap accessible? RESPONSE: All first floor units will either be handicap accessible or handicap adaptable as per the City Is•Uniform Building Code which complies with the federal A.D.A. requirements. 10. Will you be renting by the bedroom? RESPONSE: No. We anticipate that we will be renting to professionals who may be residing in Fort Collins on an interim basis and do not desire to purchase a home. There is hope that Fort Collins and C.A.T. will be the site of the new U.S.D.A. facility. With our proximity, we provide an attractive housing choice for employees who are in the rental market. 11. Will the greenbelt along Shields match the existing situation in front of Sundering Townhomes? RESPONSE: Not sure at this time, but we will try to match up. 12. Will Rolland Moore Drive be a collector or local? RESPONSE: We are designing for a collector street up to where the single family lots begin, after that, it may taper down to a local street. 13. Will the temporary fire access on the north align with Weathertop Lane in Sundering Townhomes? RESPONSE: The alignment will be close. 14. What does a fire access lane look like? RESPONSE: The fire access lane will be temporary until there is a second point of access from the east. The access must be hard surface or gravel and features a gate or chain that prevents F% MEETING MINUTES PROJECT: Windtrail Apartments and Single Family Centre for Advanced Technology Amended O.D.P. DATE: March 3, 1994 APPLICANTS: Windtrail Limited Liability Company Colorado State University Research Foundation CONSULTANT: Kay Force, Jim Sell Design PLANNER: Ted Shepard The meeting began with a description of the proposed project. As proposed, there will be eight, two-story apartment buildings for a total of 56 multi -family units. Also, 21 single family lots are proposed. QUESTIONS, CONCERNS, COMMENTS 1. What is the height of the two story buildings? Will they be two and one-half stories with berms or really two stories? RESPONSE: These will be standard two-story buildings. 2. How many bedrooms per unit? RESPONSE: In 42 units., there will two bedrooms. In 14 units, there will be one bedroom. 3. Will there be garages or open parking? RESPONSE: At this time, the two bedroom units will feature attached garages. The balance will be in open parking. 4. What are the size of the units? RESPONSE: In the two bedroom units, there will be three models ranging in size from 1,040 to 1.80 square feet. The one bedroom units will be around 720 square feet. 5. What will the rents be? RESPONSE: At this time, the two bedroom units could rent for $825 and the one bedroom units could rent for $600. 1 The single-family portion of the site consists of lots of approximately 5000 S.F., with detached homes similar in size and material to those in the adjacent Sundering Townhomes. The landscaped open space will provide a detention pond. Land Use Policies Land -use policies achieved by the proposed development include: - Policy 12-- density of at least 3 units per acre. - Policy 22-- contiguous to existing development. - Policy 46-- energy conservation through solar orientation. - Policy 80-- development has access to neighborhood center (Spring Creek Shopping Center); is close to com- munity park (Rolland Moore); water and sewer service are existing; easy access to employment (Centre for Advanced Technology ); development is on the Transfort route; alternative transporta- tion is available by the Spring Creek Bike Trail. Variance Request The applicant request a variance of the solar orientation require- ment. Lot placement was restricted by the status of Rolland Moore Drive, which precluded direct access, and by the need to provide an improved connection to Shire Court to the north. The applicant feels that the reduced number of solar lots is compensated for by improvements in the traffic pattern. Thank you for your consideration, and we look forward to your com- ments. Sincerely, JIM SELL DESIGN,INC. Kay Force March 31, 1994 im sell Ds' Planning and Zoning Board Members Planning Department City of Fort Collins RE: Wind Trail Apartments PUD Planning Objectives Dear Board Members: Windtrail Apartments is a 12.0 acre mixed use planned residential development of 77 units, providing a density of 6.4 units per acre. It is an infill project bordered by CSU Research Foundation, Sundering Townhomes, and Windtrail Townhomes. The development is within walking distance of a neighborhood shopping center and Rolland Moore Park. Access & Circulation Access and circulation consist of an extension of Rolland Moore Drive, as well as a connection to Shire Court. This connection will permit Sundering Townhome residents to enter Shields Street at a signal controlled intersection when that proposed improvement is installed. At that same time, the existing Shire Court intersection at Shields Street will be abandoned. The multi -family units will access onto Shields Street without having to travel through the single-family area. In addition, there will be no direct access from the single-family lots onto Rolland Moore Drive. Land Use The multi -family portion of the development consists of 7 8-plex units. These are two-story, with a maximum height of 28 feet. Each dwelling includes an attached garage as well as outdoor parking. All of the ground floor units are handicap accessible. 'aa 1o1vp rKn1t gP>s. Pee. DENSITY CHART Criterion Maximum Earned Credit Credit (] 2000 feet of an existing or approved neighborhood shopping center 20% b 650 feet of an existing transit stop 10% 10 C 4000 feet of an existing or approved regional shopping center 10% d 3500 feet of an existing or reserved neighborhood park, community park, or community facility 20% a0 e 1000 feet of a school, meeting all requirements of the State of Colorado compulsory education laws 10% NJ f 3000 feet of a major employment center 20% a Q, g 1000 feet of a child care center 5% m h "North" Fort Collins 20% j The Central Business District 20% jA project whose boundary is contiguous to existing urban development. Credit may be earned as follows: 30% 0% For projects whose property boundary has 0 - 10% contiguity; 10 - 15% For projects whose property boundary has 10 - 20% contiguity; 15 - 20% For projects whose property boundary has 20 - 3017o contiguity; 20 - 25% For projects whose property boundary has 30 - 4095 contiguity; 25 - 30% For projects whose property boundary has 40 -520% contiguity. 30 k If it can be demonstrated that the project will reduce non-renewable energy usage either through the application of alternative energy systems or through committed energy conservation measures beyond those normally required by City Code, a 5% bonus may be earned for every 5% reduction in energy use. j Calculate a 1 % bonus for every 50 acres included in the project. M Calculate the percentage of the total acres in the project that are devoted to recreational use. Enter 1/2 of that percentage as a bonus. n If the applicant commits to preserving permanent off -site open space that meets the City's minimum requirements, calculate the percentage of this open space acreage to the total development acreage and enter this percentage as a bonus: 0 If part of the total development budget is to be spent on neighborhood public transit facilities which are not otherwise required by City Code, enter a 2% bonus for every $100 per dwelling unit invested. p If part of the total development budget is to be spent on neighborhood facilities and services which are not otherwise required by City Code, enter a 1% bonus for every $100 per dwelling unit invested. q If a commitment is being made to develop a specified percentage of the total number of dwelling units for low income families, enter that percentage as a bonus, up to a maximum of 30%. Z f If a commitment is being made to develop a specified percentage of the total number of dwelling units for Type "A" Oand Type "B" handicapped housing as defined by the City of Fort Collins, calculate the bonus as follows: in "A" .5 x T= "A" Units Total Total Units In no case shall the combined bonus be greater than 30% Type "B" 1.0 x Tvoe "B" Units Total Units $ If the site or adjacent property contains a historic building or place, a bonus may be earned for the following: 3% For preventing or mitigating outside influences adverse to its preservation (e.g. environmental, land use, aesthetic, economic and social factors); 3% For assuring that new structures will be in keeping with the character of the building or place, while avoiding total units; 3% For proposing adaptive use of the building or place that will lead to its continuance, preservation, and improvement in an appropriate manner. f If a portion or all of the required parking in the multiple family project is provided underground, within the building, or in an elevated parking structure as an accessory use to the primary structure, a bonus may be earned as follows: 9% For providing 75% or more of the parking in a structure; 6% For providing 50 - 74% of the parking in a structure; 3% For providing 25 - 49% of the parking in a structure. U If a commitment is being made to provide approved automatic fire extinguishing systems for the dwelling units, enter a bonus of 10%. TOTAL gp 79- ACTIVITY: Residential Uses DEFINITION: All residential uses. Uses include single family attached dwellings, townhomes, duplexes, mobile homes, and multiple family dwellings; group homes; boarding and rooming houses; fraternity and sorority houses; nursing homes; public and private schools; public and non-profit quasi -public recreational uses as a principal use; uses providing meeting places and places for public assembly with incidental office space; and child care centers. CRITERIA: Each of the following applicable criteria must be answered "yes" and implemented within the development plan. l . On a gross acreage basis, is the average residential density in the project at least three (3) dwelling units per acre? (Calculated for residential portion of the site only.) 2. DOES THE PROJECT EARN THE MINIMUM PERCENTAGE POINTS AS CALCULATED ON THE FOLLOWING "DENSITY CHART" FOR THE PROPOSED DENSITY OF THE RESIDENTIAL PROJECT? The required earned credit for a residential project shall be based on the following: 30 - 40 percentage points = 3 - 4 dwelling units per acre 40 - 50 percentage points = 4 - 5 dwelling units per acre 50 - 60 percentage points = 5 - 6 dwelling units per acre 60 - 70 percentage points = 6 - 7 dwelling units per acre 70 - 80 percentage points = 7 - 8 dwelling units per acre 80 - 90 percentage points = 8 - 9 dwelling units per acre 90-100 percentage points = 9-10 dwelling units per acre 100 or more percentage points = 10 or more dwelling units per acre Land Development Guidance System for Planned Unit Developments The City of Fort Collins, Colorado, Revised March 1994 -78- No N/A U n 1JINO'TRA11- 19LT5. f0eEt-PI, Activity A: ALL DEVELOPMENT CRITERIA ALL CRITERIA APPLICABLE CRITERIA ONLY CRITERION Is the criterion applicable? Will the criterio be satisfied? If no, please explain z E LL 63 s Yes No Al. COMMUNITY -WIDE CRITERIA 1.1 Solar Orientation 1.2 Comprehensive Plan ✓ ✓ 1.3 Wildlife Habitat t/ ✓ 1.4 Mineral Deposit 1.5 Ecologically Sensitive Areas reserved reserved 1.6 Lands of Agricultural Importance 1.7 Energy Conservation t/ 1 1.8 Air Quality 1.9 Water Qualit ✓ ✓ 1.10 Sewage and Wastes ✓ 2. NEIGHBORHOOD COMPATIBILITY CRITERIA FA2.1 Vehicular Pedestrian Bike Transportation ✓ .2.2 Building Placement and Orientation 2.3 Natural Features ✓ 2.4 Vehicular Circulation and Parking ✓ ✓ 2.5 Emergency Access / 2.6 Pedestrian Circulation 2.7 Architecture 2.8 Building Height and Views 2.9 Shading ✓ 2.10 Solar Access ,/ ✓ 2.11 Historic Resources ✓ 2.12 Setbacks 2.13 Landscape V✓ 2.14 Signs ✓ 2.15 Site Lighting 2.16 Noise and Vibration 2.17 Glare or Heat 2.18 Hazardous Materials A 3. ENGINEERING CRITERIA 3.1 Utility Capacity 3.2 Design Standards 3.3 Water Hazards 3.4 , Geologic Hazards y Land Development Guidance System for Planned Unit Developments The City of Fort Collins, Colorado, Revised March 1994 -61- SCREEN WALL oErAd • .R fp.P�. PLANNING b. ZONING APPROVAL PLANT NOTES 1d.N.aMir.My�O ]L»O•.?.O� 11a tl1f Plm eGula l4�'jmaN�-amass« �vn.r waalr.e�rrw.swa+wmw arasm w�-.um �...w.m m» a»-OQ.LOfn��G�pdMM DITCH COMPANY APPROVAL .av «"oMw.�m Pa'+w'•`�.."P""^i...o. anreu�m-�oo.:asm yea I .•ammo :sneww�m�®uu � m.�ir.x�vr. ii OWNER'S CERTFICATION w �raroalww-.w-wdw.rc `� v.a»wm..ouvu.ra arseoa.ve�. nva w masPe.»..an P..oaa.n�o snian n• w. o G \'q PROJECT STATISTICS PROJECT NOTES 1 VICINITY MAP i iea.a`auiw°s .d'P� runxa.am a.a. v.lr. ��relwr v�iiaun w- w«rr war• um.� SOLAR ORIENTATION 1T4�»ID•P Y Rn4� � ��IOR a»tl tlJ�laev»aY.-0 R.aLRO1fg6W. �IVY»l.LLM vYw YC4�On KI,YI O•.M Plal.l@MtlMTBIlCln1-m fVMME1fGOlil FOR _� �GF:NOi:LYs7 e SECTION A -A PLANT KEY — ® YID T7 i{ ii Pu. ,C-- WINDTRAIL APARTMEN PRELIMINARY WTE � LANDSCAPE PLAN -AN I [1 %i:i i 6-itf.1.10 9l ■ :r_\ 1 W!\ J!\ lok �---■_-__-_--- - ■j 0 ITS wxjD SCHOOL PROJECTIONS PROPOSAL: WINDTRAIL APARTMENTS PUD - Preliminary DESCRIPTION: 77 mixed use residential on 12.05 acres DENSITY: General Population 77 units x 3.5 6.39 du/acre School Age Population (persons/unit) = 269.5 Elementary - 77 (units) x .450 (pupils/unit) = 34.65 Junior High - 77 (units) x .210 (pupils/unit) = 16.17 Senior High - 77 (units) x .185 (pupils/unit) = 14.25 Design Affected Schools Capacity Enrollment Bennett Elementary 568 483 Blevins Junior High 546 754 Rocky Mountain Senior High 1312 1404 Windtrail Apartments PUD - Preliminary, #66-93D June 27, 1994 P & Z Meeting Page 6 RECOMMENDATION: In evaluating the Windtrail Apartments Preliminary P.U.D., Staff makes the following findings of fact: 1. The P.U.D. is in conformance with the Amended Centre for Advanced Technology Overall Development Plan. 2. The Preliminary P.U.D. satisfies the All Development Criteria of the L.D.G.S. 3. The proposed density is supported by the performance on the Residential Uses Point Chart of the L.D.G.S. 4. The mix of residential densities is sensitive to and compatible with the surrounding neighborhood. 5. The request for a variance from the meeting the 65% requirement of the Solar Orientation Ordinance is justified based on the following: a. The P.U.D. as submitted is equal to or better than such a plan incorporating the provision for which a variance is requested. b. The granting of a variance would result in substantial benefit to the City by reason of the fact that the P.U.D. would alleviate an existing problem (traffic congestion) and the strict application of the Solar Orientation Ordinance would render the project practically unfeasible. Staff, therefore, recommends: 1. Approval of the variance request from the strict application of achieving a 65% compliance rate as per the Solar Orientation Ordinance. 2. Approval of the Windtrail Apartments Preliminary P.U.D., #66- 93D. Windtrail Apartments PUD - Preliminary, #66-93D June 27, 1994 P & Z Meeting Page 5 Also, as directed by Staff, the P.U.D. indicates a local street connection to the north referred to as Shire Way. This local street is considered to be a vital connection for the surrounding neighborhoods to gain access to Shields Street. In accordance with the original Sundering Townhome P.U.D., the existing Shields Street/Shire Court intersection will be closed, when there is an opportunity for alternative access to Shields. The applicant states that this transportation element precludes the design of another cul-de-sac which may have resulted in more solar lots. Staff finds that by mitigating access and transportation issues, the P.U.D., has met important public objectives. It is Staff's finding that the P.U.D. is equal to or better than a plan that would have normally met the solar orientation requirements. Staff, therefore, recommends the variance be granted. 6. Transportation: As mentioned, access to Shields Street will be via an extension of the existing access drive that serves Rolland Moore Park. With this extension, this access drive becomes a public street on the east side of Shields now referred to as Rolland Moore Drive. This intersection will be eligible for a traffic signal in the future as conditions warrant. Rolland Moore Drive will be a collector street to the easterly property line of the P.U.D. From this point, Rolland Moore Drive will swing northeast to serve the other Windtrail P..U.D.'s and Tract H of the C.A.T. Amended Overall Development Plan. As it makes this turn, the street may be downsized to a local street. Shire Way is designed to intersect with Shire Court to the north. This will provide access to the Shields/Rolland Moore intersection and allow the Shields/Shire Court intersection to be closed. The closure of the Shields/Shire Court intersection is part of the original approval of Sundering Townhomes P.U.D. Although specific details have not been finalized, it is expected that this closure will be permanent in that existing asphalt, curb, and gutter will be removed. A new sidewalk would be built across the throat of the present intersection. The exact scope of the project, however, remains to be determined. The P.U.D. has been reviewed by the Transportation Department. The project -is feasible from a traffic engineering standpoint and complies with transportation policies.' r Windtrail Apartments PUD - Preliminary, #66-93D June 27, 1994 P & Z Meeting Page 4 4. Desian• The design features of the P.U.D. are summarized as follows: A. Lots One Through Five Access to Lots One through Five will be by a looping common access drive separated from Rolland Moore Drive by a 19 foot landscaped island. Since Rolland.Moore Drive will be a collector street in this section, it is desirable not to have individual drive -way cuts with direct access. B. Streetscaping: Shields Street and Rolland Moore Drive Along Shields, the two-story apartment buildings will be buffered by a combination of a brick fence, berms, and landscaping. Additional street trees will complement the existing trees that were planted with the City's street widening project. Along Rolland Moore Drive, street trees will be planted on both sides of the street from Shields to the easterly limits of the project. C. Buffering for Sundering Townhomes There are existing townhomes that will be impacted by the single family lots. These townhomes will be buffered by the detention pond and a 30 foot wide drainage easement. 5. Solar Orientation: There are 21 lots that are eligible for meeting the requirements for solar orientation. Of these 21, 11 are oriented to within 30 degrees of a true east -west line, or have a south property line that is adjacent to a minimum of 50 feet of unobstructed open space. This results in a compliance rate of 52%. The Solar Orientation Ordinance requires that 65%. or 14 lots, meet the siting requirements. The applicant, therefore, has requested a variance as part of the Preliminary P.U.D. request. (The Planning and Zoning Board is empowered to grant variances to this section based on the criteria of Section K, page 108, of the L.D.G.S.) In the variance request, the applicant states that the site is constrained by Rolland Moore Drive being designated by the City's Transportation Department as a collector street. Since individual lot access to a collector street is discouraged, this limited the number of north -south lots on the north side of Rolland Moore Drive. Windtrail Apartments PUD - Preliminary, #66-93D June 27, 1994 P & Z Meeting Page 3 park, a major employment center, and for contiguity to existing urban development. The Preliminary P.U.D., with a proposed density of 6.39 dwelling units per acre, is supported by the score of 80% on the Residential Uses Point of the L.D.G.S. 3. Neighborhood Compatibility: Two neighborhood meetings were held in concert with amending the Centre for Advanced Technology Overall Development Plan. Minutes to these meetings are attached. The primary concerns are related to transportation. There is a concern that Hill Pond Road not become a through street that connects over to Centre Avenue. There is also a concern that all three Windtrail projects have an outlet onto Shields that does not impact Hill Pond Road. The Preliminary P.U.D. indicates that Rolland Moore Drive will provide access to Shields Street. This intersection will be eligible for a future traffic signal as conditions warrant. Rolland Moore Drive is stubbed to the easterly property line in anticipation of extending north to serve the balance of the Windtrail area. This will allow traffic from Windtrail Townhomes and Windtrail on Spring Creek, Phase Two, to have an alternative outlet to Shields Street other than sole reliance on Hill Pond Road. Until Rolland Moore Drive is extended north, access to Shields will be via Shire Court and Shire Way. The concern over Hill Pond Road not becoming a direct connection over to Centre Avenue has been addressed by the Centre for Advanced Technology Amended Overall Development Plan. As amended, the O.D.P. indicates that Science Drive will make the Rolland Moore Drive/Centre Avenue connection, not Hill Pond Road. The location of Science Drive is offset from Hill Pond Road which will discourage "cut -through" traffic. Other concerns were height, the number of bedrooms per unit, and rental by the room versus by the unit. The multi -family buildings will be two stories in height. There will be a mix of bedrooms with no unit exceeding three bedrooms. Rental arrangements will be by the unit, not the bedroom. Staff finds that the Preliminary P.U.D. will fit in and be sensitive to the surrounding neighborhood. The P.U.D. is considered compatible with existing and future development. Windtrail Apartments PUD - Preliminary, #66-93D June 27, 1994 P & Z Meeting Page 2 COMMENTS: 1. Background• The surrounding zoning and land uses are as follows: N: R-P; Existing Multi -Family (Sundering Townhomes) S: I-P; Existing Nursing Home and Congregate Care E: R-P; Vacant W: R-L; Rolland Moore Community Park The original Centre for Advanced Technology Overall, Development Plan was approved in 1985. In 1988, a Preliminary P.U.D. was approved on Tract J for a senior service center and a 120-bed full - care nursing home. This P.U.D. is considered expired. North of the subject site,, and east of Hill Pond and Sundering Townhomes, two other Windtrail projects have been approved. Windtrail Townhomes consists of 37 units on 6.23 acres and was granted Final P.U.D. on January 24, 1994. Windtrail on Spring Creek, Phase Two consists of 35 single family lots on 16.3 acres and was granted Final P.U.D. on April 25, 1994. 2. Land Use: The Preliminary P.U.D. consists of seven, two-story apartment buildings with eight units per building. In addition to 56 multi- family units, there are 21 single family lots for a total of 77 dwelling units. With 12.05 gross acres, the density is 6.39 dwelling units per acre. A. Overall Development Plan The existing Centre for Advanced Technology O.D.P. is being amended in conjunction with the Preliminary P.U.D. The amended O.D.P. would re -designate Parcel J to "Mixed Residential." Based on this amendment, the proposed P.U.D. is compatible with the C.A.T. Overall Development Plan. B. Residential Uses Point Chart The request was evaluated by the criteria of the Residential Uses Point Chart of the L.D.G.S. The P.U.D. satisfies the absolute criterion that, on a gross acreage basis, the average residential density be at least 3.00 dwelling units per acre. On the variable criteria, the P.U.D. achieves a score of 80%. Points were earned for proximity to a transit stop, a community d ITEM NO. 7 MEETING DATE 6127/94 City of Fort Collins PLANNING AND ZONING BOARD STAFF REPORT PROJECT: Windtrail Apartments Preliminary P.U.D., #66-93D APPLICANT: Windtrail Limited Liability Company c/o Jim Sell Design 117 East Mountain Avenue Fort Collins, CO 80524 OWNER: Colorado State University Research Foundation P.O. Box 483 Fort Collins, CO 80522 PROJECT DESCRIPTION: This is a request for Preliminary P.U.D. for 56 multi -family units and 21 patio home lots, for a total of 77 units, on Parcel J of the Centre for Advanced Technology Overall Development Plan. The site is located on the east side of Shields Street, across from Rolland Moore Park, and south of Sundering Townhomes. The property is 12.05 acres and zoned R-P, Planned Residential. RECOMMENDATION: Approval EXECUTIVE SUMMARY: Windtrail Apartments is located on Tract J of the Centre for Advanced Technology O.D.P. which is being considered for an amendment concurrently with this P.U.D. request. The Preliminary P.U.D. is in conformance with the C.A.T. Overall Development Plan, as amended. The P.U.D. satisfies the All Development Criteria and the Residential Uses Point Chart of the L.D.G.S. The mix of residential densities is found to be compatible with the surrounding neighborhood. For the 21 single family lots, the P.U.D. is three lots short of achieving the mandatory 65% compliance rate for solar orientation. A variance is recommended. The P.U.D. complies with transportation policies. COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box 580 Fort Collins, CO 80522-0580 (303) 221-6750 PLANNING DEPARTMENT