Loading...
HomeMy WebLinkAboutWATERGLEN PUD REPLAT #1 - 71 93C - REPORTS - RECOMMENDATION/REPORTWaterglen PUD, Replat #1—File #71-93C May 29, 2001 Administrative Hearing Page 4 RECOMMENDATION: Staff recommends approval of the,Waterglen PUD Replat #1, file # 71-93C with the following condition: 1. Prior to Director approval, the applicant will revise the plat to include cross access easements between Tracts Q-1, Q-2 and P-1 consistent with the approved PUD and subsequent minor amendments. Waterglen PUD, Replat #1— File #71-93C May 29, 2001 Administrative Hearing Page 3 B. The replat is in compliance with Section 3.3.1(B) Lots in that: 1) Each lot has direct vehicular access to a public and the side lot lines are substantially at right angles or radial to the street lines. 2) The general layout of lots, roads, driveways, utilities, drainage facilities and other services within the proposed development were established with the approval, filing, and recording of Waterglen PUD. The design of the adjacent platted roads is unaffected. C. The replat is in compliance with Section 3.3.1(C) Public Sites, Reservations and Dedications in that: 1) The rights -of -way for the adjacent streets (East Vine Drive and Waterglen Drive) and the drainage and utility easements necessary to serve this area were dedicated with the Waterglen PUD Subdivision plat that is on record in the City of Fort Collins. The reconfigurations of the lots and tracts change the shapes of the necessary access, utility, and drainage easements. The new easement configurations continue to adequately serve the access, utility, and drainage needs. All utilities currently using the existing easement configuration have reviewed this request, and have no conflicts with the new configuration. 4. Findings of Fact/Conclusion: A. The Waterglen PUD Replat #1 contains permitted uses in the LMN - Low Density Mixed Use Residential Zoning District. B. The Waterglen PUD Replat #1 meets -the procedural requirements located in Division 2.1 - General Procedural Requirements, Division 2.2 - Common Development Review Procedures for Development Applications, and Section 2.4 - Project Development Plan located in Article 2 - Administration. C. The Waterglen PUD Replat #1 meets the plat requirements located in Section 3.3.1 - Plat Standards located in Article 3 - General Development Standards. Waterglen PUD, Replat #1— File #71-93C May 29, 2001 Administrative Hearing Page 2 COMMENTS: 1. Background: Existing Zoning Existing Land Use North LMN Single Family Residential (Developing) South Industrial Undeveloped East Industrial 1-25 West LMN Single Family Residential (Developing) The Overall Development Plan for this project was approved March 7, 1994 by the Planning and Zoning Board. The PDP was approved in July of 1994. 2. Article 2 - Administration: The request complies with the applicable requirements of the LUC, specifically the procedural requirements located in Division 2.1 - General Procedural Requirements, Division 2.2 - Common Development Review Procedures for Development Applications, and Section 2.4 - Project Development Plan located in Article 2 - Administration. 3. Article 3 - General Development Standards: The request complies with the applicable requirements of the LUC, specifically the plat requirements located in Section 3;3.1 - Plat Standards located in Article 3 - General Development Standards. A. The replat is in compliance with Section 3.3.1(A) General Provisions in that: 1) The subdivision plat will be filed and recorded only after having been approved by the Director of Planning, with such approval evidenced in writing on the plat and signed by the City Clerk. 2) No building permit or certificate of occupancy shall be issued for construction of any new principal building or no act which changes the use of any building shall be permitted until the subdivision plat is filed and recorded in the City of Fort Collins. ITEM NO. MEETING DATE 5/29/01 STAFF Bria'n C'rubb Citv of Fort Collins HEARING OFFICER STAFF REPORT PROJECT: Waterglen PUD Replat #1; File #71-93C [Type I, Administrative Review] OWNER: Waterglen LLC and Waterglen Holdings LLC 361 71s`Avenue, Suite 103 Greeley, Colorado 80634 APPLICANT: JR Engineering c/o Jim Wright 2620 East Prospect Road, Suite 190 Fort Collins, CO 80525 PROJECT DESCRIPTION: This request is to replat Tract P (Multifamily) and Q (Mixed Use) of Waterglen PUD Subdivision into four tracts being call P-1, P-2, Q-1 and Q-2. The primary purpose of this replat is to subdivide the floodplain from the rest of the parcel for insurance and development permitting purposes. Once the floodplain is subdivided from the rest of the parcel, the owners will not need flood insurance or a flood hazard development permit to build. The replat also subdivides tract Q, the mixed -use parcel into two parcels. The lots and tracts affected by this replat are all in the in the LMN (Low Density Mixed Use Neighborhood) zone district. RECOMMENDATION EXECUTIVE SUMMARY: Approval with One Condition This request complies with the applicable requirements of the Land Use Code (LUC), specifically the procedural requirements located in Division 2.1 - General Procedural Requirements, Division 2.2 - Common Development Review Procedures for Development Applications, and Division 2.4 - Project Development Plan located in Article 2 - Administration; and Section 3.3.1 - Plat Standards located in Article 3 - General Development Standards, COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box 580 Fort Collins, CO80522-0580 (970) 221-6750 PLANNING DEPARTMENT