Loading...
HomeMy WebLinkAboutBOSTON CHICKEN PUD MAJOR AMENDMENT - 79 93B - SUBMITTAL DOCUMENTS - ROUND 1 - GEOTECHNICAL (SOILS) REPORTTf,kNNOLOGY OL ORATORY, INC. Project Name: Shipped by: Results to the attention of: Sampling Point Sampler(s) (signature) Field Cl.-a, of Custody Record �i&o /4 /+vr.Sif&- Project No. o 44,640 k)j44 Sample No. of Analysis Location Sample ID Date Type Containers Required �A% by: / Time yJ•.,...... vl. Jay ... IUFUr vale r i ifne rseceiveo for Laboratory by: Date / Time l (sign re) Sealed for shipment by: (signature) Date/Time Shipment method: Comments: by: TECHNOLOGY LABORATORY, INC. CENTRE FOR ADVANCED TECHNOLOGY 2401 Research Boulevard, Suite 204 Fort Collins, Colorado 80526 (303) 490-1414 WATER ANALYSIS REPORT COLORADO BUILDING INSPECTION SERVICE P.O. Box 9614 Fort Collins, Colorado 80525 Sample ID: Hole #2 @ 12' Lab ID: 7485 Compound Analyzed Benzene Toluene Ethylbenzene Total Xylenes TVPH (Purgeable) Compound Concentration (ue/L) <0.5 <0.5 <0.5 <0.5 <0.5 mg/L Sampled: 11/8/93 Received: 11/30/93 Analyzed: 12/7/93 Project No: Boston Chicken SURROGATE RECOVERIES `7c Recovery Fluorobenzene ' 98 Bromolluorobenzene .114 MIR - :..... Method (Detection Limit EPA-8020 (0.5 µg/L) EPA-8020 (0.5 µg/L) EPA-8020 (0S µg/L) EPA-8020 (0.5 µg/L) EPA-8015 Modified (0.5 mg/L) Recovery Limits 75-125 75-125 Colorado Building Inspection Service An Affiliate of William J. Warren & Son, Inc. Post Office Box 9614 Fort Collins, Colorado 80525 303-482-1976 303-226-3388 FAX 51817th Street, Suite 1230 Denver, Colorado 80202 800-248-1976 Boston Chicken c/o Mark Nelson A Delaware Corp. 9034 E. Easter Place Englewood, CO 80112 December 10, 1993 The attach2d laboratory report confirms that a water sample collected at your Lemay Avenue, Ft. Collins site does not contain elevated petroleum hydrocarbon levels. Your account is fully paid. We look forward to the opportunity to continue to provide you with environmental and/or building inspection services. Sincerely, William J. Warren President Colorado Building Inspection Service P.I. #208 VA/FHA Compliance Inspector #0517 International Conference of Building Officials Professional AHERA/EPA/State of Colorado Asbestos Inspector and Management Planner Senior Certified Environmental Inspector #5057 Certified Construction Inspector #2553 EPA Radon Measurement Proficiency Contractor & Primary Laboratory cc: Ed Zdenek WMAN VELDMAN MORGAN C O M M E R C I A L 10 October 1997 Leanne A. Harter, AICP City Planner Current Planning Department 281 North College Avenue Fort Collins, CO 80522-0580 Dear Leanne: Per your direction, no Subsurface Hydrology Study is required. I did, however, enclose a water sample report that is dated December 10, 1997. You requested this report to satisfy the Subsurface Hydrology Study checklist item as outlined in the Submittal Checklist for the Combined Project Development Plan (PDP) and Final Compliance Review. Please call me if you have any questions. Sincerely, VE DMAN MORGAN COMMERCIAL, INC. Daniel R. Bemth Broker Associate 760 Whalers Way, Bldg. C, Suite 200 Fort Collins, CO 80525 Phone 970/223-5555 Fax 970/223.1647