Loading...
HomeMy WebLinkAbout329 S SHERWOOD NCM ADVISORY REVIEW - 73 93 - CORRESPONDENCE -needed, then the developer pays tap fees for the difference between the existing size and the new size. Please contact Mark Taylor, 221-6681, for further details. 5. The conversion work must be done by contractors and subcontractors licensed in the City of Fort Collins. The design of the wall units must be engineered and stamped by a registered professional engineer. Egrees windows on the north and south must meet the Uniform Building Code as adopted and amended by the City of Fort Collins. As an R-1 occupancy, the structure will require one -hour fire -rated walls between units. The separation between the basement and the living unit must also be one -hour rated. For further information regarding issues related to the Uniform Building Code, please contact Mike Gebo, 221-6760. ft 6. Each unit will be required to have separate sources of heat and be equipped with 100 amp electrical panels. 7. The Poudre Fire Authority will require access to the rear of the building for fire rescue purposes. This may require a non -build easement from the neighbor to the north. Such an easement must be in writing and in place before the project can be approved. 8. The Parks and Recreation Department will assess a Parkland Development Fee of $779 per unit, payable at the time of building permit issuance. 9.. The Stormwater Utility is concerned if there will be an increase in impervious surface area of greater than 350 square feet. outdoor wood decks, with no enclosures, do not apply. If there is to be no change or a decrease in impervious surface, please provide a letter to the Stormwater Utility. For further information, please contact Glen Sch.,ueter, 221- ------ 6589'- 10. The Engineering Department will charge $584 per unit for the Street oversizing Fee, payable at the time of building permit issuance. ' 11. The reconstruction of the driveways, ramps, and the new parking area along Magnolia Street will require a detailed plan submitted to the Planning Department along with the submittal for the residential conversion. This could be as simple as a detail on the Site Plan. Driveways should be a minimum of 20 feet in length so there is no vehicular overhang onto the sidewalk. For further information regarding these improvements, please contact Kerrie Ashbeck, 221-6750. 12. Please be aware that the public administrative hearing cannot occur until the plans are in final form and legal advertising requirements have been met. CONCEPTUAL REVIEW STAFF COMMENTS Fort MEETING DATE: October 25, 1993 ITEM: Conversion of 329 South Sherwood Street to Residential APPLICANT: Mr. Bill Coulson, 221 Mathews Street, #(20, Fort Collins, Co 80524 LAND USE DATA: Request to convert the old University Cleaners at 329 South Sherwood Street to three residential units. COMMENTS: 1. The property is located in the N-C-M zone district. This zone allows conversions to residential (up to four-plex) with no exterior alterations to be considered administratively by the Planning Director. If there are exterior alterations, then the request must be considered by the Planning and Zoning Board. Both processes require submittal of a site plan. 2. The site plan must demonstrate that the bulk and area requirements (setbacks) of the N-C-M zone are satisfied. If this is not the case, then the necessary variances must be submitted to the Zoning Board of Appeals, or the project must be submitted. as a planned unit development for consideration by the P & Z Board. 3. In terms of the electrical secondary service, what is existing is probably adequate to serve three 'residential dwelling units. The transformer may or may not have to be changed out. If it needs to be changed out, then the cost is approximately $275. The normal development charges for residential units would apply but may be modified given that there was recently an existing commercial use. For further information, please call Alan Rutz, Light and Power, 221-6700. 4. The property is likely served by a 3/4 inch water tap. If this service is adequate, then there are no issues with the Water and Sewer Department. This service line should be checked. If it is old (galvanized steel) and corroded, then the line may be inadequate to serve the needs of three two - bedroom apartments. If a new water service is needed, then it must be tapped back at the main. If a larger service is rn...nw.ry n. . ENVIRONMENTAL SERVICES 281 NORTH COLLEGE P.O.BOX 580 FORT COLLINS, COLORADO80522-0580 (303)221-6750 PLANNING DEPARTMENT