HomeMy WebLinkAboutBOSTON CHICKEN PUD PRELIMINARY - 79 93 - CORRESPONDENCE -Pennock Place PUD Comments
October 27, 1993
Page 4
standing signs must be downsized accordingly. Each user will not be allowed a sign the size
the Godfather's Pizza. Free-standing signage will be restricted in height in the six to eight foot
range. Low rectangular or square signs are preferred over tall rectangular signs.
21. Staff will expect the two users to submit architectural elevations that demonstrate site
unity and cohesion. Since the site is being developed as a unit, there must be a degree
uniformity between the two users. Vastly different use of materials, colors, roof styles, etc. will
not be permitted. If this means modification of a national, corporate standard, then Staff will
work closely with the applicant so that our mutual goals are achieved.
Pennock Place.PUD Comments
October 27, 1993
Page 3
12. The site plan indicates a drive -through lane entrance near the Pennock/Lemay
intersection. This will cause conflicts with stacking and should be re -designed.
13. The sidewalk system should be continuous from Riverside to Elizabeth. The developer
is responsible for installing a five foot wide, detached sidewalk along the property's frontage.
The walk should be setback from the flowline by nine feet. The sidewalk is allowed to meander
and be located outside the public right-of-way as long as it is placed within a dedicated access
easement. The City's Street Oversizing Fund will participate, to a limited degree, in the
construction of this sidewalk.
14. The traffic impact analysis will determine the need for a deceleration lane on Lemay
Avenue. If a decel lane is required, then the required right-of-way dedication for the arterial:
cross-section must be expanded to account for the additional width.
15. The conceptual plan lacks the location of the trees, sidewalk, and decel lane, (if
required). It is suggested that a meeting occur with the Planning, Engineering, and
Transportation Departments prior to submittal of a Preliminary P.U.D. to discuss these issues.
16. The internal parking spaces near the Pennock/Lemay intersection may be too close and
could interfere with traffic movements.
17. The developer is cautioned that modifications to the west side of the Pennock/Lemay
intersection may have to implemented in order to gain the proper alignment on the east side.
18. The streetscape treatment along Lemay will be of critical concern, especially for such
intense uses as two restaurants, with drive -through. There will need to be sufficient buffering
so that parked cars, menu boards, and service areas are screened from one of the City's busiest
arterials. This may require berming, evergreens, or a low decorative wall. Headlight glare onto
Lemay will not be permitted.
19. Menu boards will count as free-standing signs and must obtain a variance from the
Zoning Board of Appeals.
20. Signage is considered a critical design element of the P.U.D. Since there will be two
users, Staff will not allow the two users to compete for signage by trying to "outshout" each
other. Free-standing signage must be based on a monument that matches the building exterior.
Wall signage must be individual letter or a cabinet where only the letters are illuminated and: the
background is opaque. Large, glaring illuminated awnings will not be permitted. It is preferred
that one free-standing sign serve both restaurants. If this is not possible, then individual free-
Pennock Place PUD Comments
October 27, 1993
Page 2
converted at some point in the future and new users could install frying equipment. Presently,
the Building Inspection Division and the Water and Wastewater Department do not have a
trigger mechanism by which to require a new user to install exterior grease traps. It may be that
grease traps must be installed with the initial construction. Please contact Mark Taylor, 221-
6681, for further discussions.
7. Poudre Fire Authority may require an additional hydrant to be placed on -site to serve the
southerly parcel. Fire access must maintained around both buildings. If there are uncontained
areas greater than 5,000 square feet, then these areas must be equipped with an approved,
commercial -grade, automatic fire extinguishing system.
8. There are large mature trees on the property which may or may not be in the future
alignment of the extension of Pennock Place. The developer must contact the City Forester, .
Tim Buchanan, 221-6640, for an evaluation of any trees before these_ trees are pruned, altered,
or removed.
(The City Forester and the Planning Department recently experienced a property owner
who removed substantial mature vegetation on a site after bringing the site through the
conceptual review process but before submitting for a Preliminary P.U.D. We are
confidant that such bad -faith tactics will not be the case on this property and we look
forward to resolving the tree preservation issue on a reasonable basis.)
9. The site is located in the Old Town Drainage Basin. As of this writing, there are no
Storm Drainage Fees in this basin. The City Council, however, will take action in November
and December of this year (1993) to approve a new Storm Drainage Fee in this basin. It is
estimated that the fee will be in the $5,000 per acre range.
10. On -site stormwater detention will be required. It will be up to the developer's engineer
to verify the capacityof the Riverside storm drain. A standard Drainage Report, Drainage and
Grading Plan, and Erosion Control Plan will be required.
These documents must be submitted in accordance with the checklist and criteria of the
Stormwater Utility. If these documents do not satisfy the submittal requirements, the
project will be held up and not forwarded to the Planning and Zoning Board for
consideration until brought into compliance.
11. A traffic impact analysis will be required. The internal circulation must serve the
adjacent properties so as to lessen the reliance on Lemay Avenue. The Transportation
Department will assist the applicant in meetingwith the adjacent property owners to discuss
internal connections. In Pennock Place/Lemay is signalized, then it will benefit the adjacent
property owners to gain access to this intersection.
CONCEPTUAL REVIEW STAFF COMMENTS
MEETING DATE: October 25, 1993
ITEM: Pennock Place P.U.D., Located on the East Side of South Lemay Avenue, 800 block,
between Godfather's Pizza and Lemay Animal Hospital
APPLICANT: Mark Nelson c/o Ed Zdenek, ZTI, 1220 South College Avenue, Fort Collins,
CO. 80524.
LAND USE DATA: Request for two standard restaurants, with drive -through, at the corner of
Pennock Place and South Lemay Avenue across from Riverside Shopping Center.
COMMENTS:.
1. There is three-phase electrical power along Lemay Avenue that is available to serve the
site. An electrical contractor must complete the "Commercial -One" form to determine entrance
capacity. Any modifications to the existing system is an expense borne by the developer.
2. Every attempt should be made to size the electrical transformer to serve both sites. The
location should be such so that this can be accomplished. The transformer location will not be
allowed to be placed along the Lemay Avenue streetscape. It must be located internal to the site
and screened from public view by an approved enclosure meeting the minimum clearance
requirements or by landscaping. There must be hard surface access from one side for
emergency change -out capability. without destroying landscaping.
3. A water main is available on the east side Lemay. A sewer main is available on the west
side of Lemay.
4. There is an old 4 inch diameter water line that is stubbed to the property which comes
down from Elizabeth. This line should be abandoned according to the specifications of the
Water and Wastewater Department.
5. The depth of the sewer may be problem. The developer is strongly encouraged to
investigate and verify the sewer depths.
6. The Water and Wastewater Department is concerned about installing exterior grease traps
for both restaurant users.. Although the proposed restaurants (Boston Chicken and an unnamed
restaurant) are represented as not using fryers, there is a concern. that ownership could be
... ,I.,.,..,.:
ENVIRONMENTAL SERVICES 281 NORTH COLLEGE P.O-BOX 580 FORT COLLINS, COLORADO 80522-0580 (303)221-0750
PLANNING DEPARTMENT
Community fanning and Environmental Ser. _es
Planning Department
City of Fort Collins
October 27, 1993
Mr. Ed Zdenek
ZTI
1220 South College Avenue
Fort Collins, CO 80524
Dear Ed,
For your information, attached is a copy of the Staff s comments concerning the Pennock Place
P.U.D., that was presented before the Conceptual Review Team on October 18, 1993.
The comments are offered informally by Staff to assist you in preparing the detailed components
of the project application. Modifications and additions to these comments may be made at the
time of formal review of this project.
If you should have any questions regarding these comments or the next steps in the review
process, please feel free to call me at 221-6750.
Sincerely,
�l
Ted Shepard
Senior City Planner
Attachment
xc: Tom Peterson, Planning Director
Kerrie Ashbeck, Civil Engineer
Transportation Department
Project Planner
File