HomeMy WebLinkAboutWOODLAND STATION PUD - PRELIMINARY ..... 2/07/94 CONCEPTUAL REVIEW - 18-94B - CORRESPONDENCE -t
21. The use of "eyebrows" does not meet City Code. Rather,. please
use a cul-de-sac design that narrows the opening to a standard
street width.
22. The use of a median in a local street requires a variance.
The variance to an engineering standard requires the submittal
of written documentation from a professional engineer
registered in the State of Colorado.
23. The Street Oversizing Fee is $584 per dwelling unit, payable
at the time of building permit issuance.
24. A Soils Report will be required. This report will indicate
the groundwater situation and the need for a sub drain system
if basements are desired. If basements are desired and
requires a sub drain system, then a hydrologic study must
accompany the Soils Report. A sub drain system must have an
approved outlet and meet other City design criteria.
25. The annexation process must be complete before a P.U.D. will'
be allowed to be submitted. Annexation requires an
authorization resolution by City Council, followed by a
recommendation by Planning and zoning Board, followed by two
readings by City Council. At this time, the recommended
zoning will R-L-P, Low Density Planned Residential, with a
condition that development occur as a Planned Unit Development
in accordance with the Land Development Guidance System.
26. It is recommended that lots that back up to C.R. #9 be deeper
than 110 feet for acoustic and visual buffering.
27. Fencing and streetscaping along C.R. #9 will be reviewed as
part of the P.U.D.
28. Preliminary building elevations will be reviewed as part of
the P.U.D.
29. A neighborhood information meeting will be required.
M1
11. As presently indicated, the site does not share internal
street connections with adjacent properties to the north and
east. Internal street connections are needed to resolve the
second point of access issue for compliance with the Poudre
Fire Authority. Also, internal street connections are needed
to be in compliance with City policies that recirculation and
travel within a square mile section be accommodated within the
local street network and not impact the traffic on the
adjacent arterial street. Please investigate connecting local
streets to the adjacent properties.
12. The parcel to the east that relies upon the.30 foot wide
access easement should be provided access to the public street
system within the proposed subdivision.
13. Similarly, the one acre out parcel for the existing house
should also be given an internal access via local streets
rather than have a separate curb cut on the arterial street.
14. Are there any bicycle/pedestrian paths planned for the
subdivision? Providing off-street paths to the park area
would be an amenity, especially for children.
15. It is suggested that additional meetings occur with the
adjacent property owners to the east, north, and west in order
to investigate the "big picture" issues regarding access and
circulation in the area.
16. A traffic impact analysis will be required. The City
maintains a list of engineering consultants who are familiar
with the City's requirement for a traffic study. The
consultant selected should contact the Transportation
Department to determine the scope of the study.
17. The first internal intersection east of County Road #9 may
have to be shifted further east in order to maintain the
proper distance from the arterial intersection. This area is
needed for stacking for drivers desiring to. turn left, south,
on C.R.#9.
18. Along C.R.#9, the developer is obligated to dedicate land area
so there is 50 feet of half -width on east side of C.R. #9. In
addition, a 15 foot wide utility easement is required outside
of the public right-of-way.
19. The developer is obligated to construct arterial street
improvements along C.R. #9• This includes a five foot wide
detached sidewalk, curb, gutter, and approximately 12 feet of
pavement. This obligation will be secured by.a Development
Agreement made between the City and the developer.
20. For the portion of the arterial that exceeds the developer's
obligation, the City will be financially responsible and
reimburse the developer for these costs.
density- single family and lower the fee for multi -family. For
further information, please contact Leslie Bryson, 221-6640.
6. The single point of access to a depth of 1,215 feet exceeds
the allowable 900 foot length. The Poudre Fire Authority will
not support a variance to allow the lot layout as proposed
without a second point of access. All lots must within 400
feet of a fire hydrant. There must be a minimum flow of 1,000
gallons per minute at all hydrants. with 20 psi residual
pressure. For further information, please contact Mike Pretz,
Poudre Fire Marshal, 221-6570.
7. The site is located in the Fox Meadows Drainage Basin. The
Stormwater Drainage fee in this basin is $4,891 per acre,
subject to the amount of impervious surface and the runoff
coefficient. A standard Drainage Report, Drainage and Grading
Plan, and Erosion Control Plan are required at the time of
submittal.
8. Detention is required for this property. According to the Fox
Meadows Drainage Basin Master Plan, the outfall for the
detention pond is the Fossil Creek Reservoir inlet ditch,
located east of the subject property. The property will be
restricted to a release rate at the two year historic flow.
An offsite easement will be required to be obtained from the
intervening land owners to get storm flows to the approved
outfall. This will require negotiation with the adjacent
property owners to the east.
9. If the adjacent property owners rely upon storm water flows
for irrigation or other purposes, then the quality.of the
stormwater runoff may be an issue. This. may require a
sedimentation pond or other devices to filter the runoff. In
addition, there may a concern with urban runoff and the need
to filter for grease and oil. For further information, please
contact Glen Schlueter, Stormwater Engineer, 221-6589.
10. The Transportation Department is concerned about the number of
street intersections along County Road #9. As an arterial
street, there should be a limited number of intersections in
the one mile section between Harmony and Horsetooth Roads.
The developer is encouraged to work with the property owners
along this one mile section to determine the best locations
for street intersections. It is suggested that a map be
prepared that illustrates the existing and proposed
conditions.
Please be aware that English Ranch is an approved Overall
Development Plan (Spring Creek Farms) that calls for an east -
west collector street that will intersect with County Road#9.
Other considerations are the existing curb cuts for H-P, the
proposed curb cuts for Johnson Property (N.C.R.) and the
existing situation north of the property.
I
CONCEPTUAL REVIEW STAFF COMMENTS
MEETING DATE: February 7, 1994
ITEM: Strachan Farm, east side of County Road #9
APPLICANT: Mr. Brad Bennett, 8101 East Prentice Avenue, Suite
815, Englewood, CO. 80111.
LAND USE DATA: Request to subdivide 18 acres into residential lots
for 64 single family lots (option one), or 90 single family lots
(option two), or 91 single family lots (option three). The site is
located on the east side of County Road #9, north of Hewlett-
Packard. The site is in the Urban Growth Area but not annexed into
the City. One acre would be reserved for the existing house.
COMMENTS:
1. The City Light and Power Department has existing underground
electrical system up to the north side of the developed
portion of the Hewlett-Packard facility. This system is
available to serve the site. With the existing trees,
however, it' is impossible to extend electrical facilities
within the County Road right-of-way. There are other existing
utilities in County Road #9 which makes it difficult to extend
electrical facilities. Normal development charges will apply.
For further information, please contact Doug Martine, 221-
6700.
2. The City Water and Wastewater Department has a 24 inch
diameter water main and a 24 inch diameter sewer main in
County Road #9 that can serve the site. These mains are on
the west side of the road and have sufficient capacity.
Please contact Mark Taylor, 221-6681 for further details.
3. The Department of Natural Resources would encourage that as
many trees remain undisturbed as possible. The City Forester,
Tim Buchanan, should be called upon to inspect and evaluate
the existing trees.
4. A homeowner's association should be set up to maintain common
area landscaping, including landscaping along the frontage of
County Road #9 that is located in the public right-of-way.
5. The Parkland Development Fee is $779 per dwelling unit payable
at the time of building permit issuance. The City Council is
presently exploring options that would raise this fee for low
COMMUNITY PLANNING &
ENVIRONMENTAL SERVICES 281 NORTH COLLEGE P.O.BOX 580 FORT COLLINS, COLORADO 80522-0580 (303)2216750
PLANNING DEPARTMENT
a
Commuiuty Planning and Environmental bervices
Planning Department
City of Fort Collins
February 28, 1994
Mr. Brad Bennett
8101 East Prentice Avenue, Suite 815
Englewood, CO 80111
Dear Mr. Bennett:.
For your information, attached is a .copy of the Staf.f's comments concerning
Strachan Farm, east side of County Road 419, presented before the Conceptual
Review Team on February 7, 1994.
The comments are offered informally by .Staff to assist you in preparing the
detailed components of the project application. Modifications and additions to
these comments may be made at the time of formal review of this project.
If you should have any questions regarding these comments or the next steps in
the review process, please feel free to call me at 221-6750.
s;ncerel ,
Ted Shepard, A P
Senior Planner
TS/gjd
Attachments
cc: Transportation Department
Stormwater Department
Project Planner
File
281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 �- (303) 221-6750