HomeMy WebLinkAboutWOODLAND STATION PUD - PRELIMINARY ..... 5/31/94 CONCEPTUAL REVIEW - 18-94B - CORRESPONDENCE -i
15. Utility Plans are required at the time of submittal, meeting
the requirements of the Engineering Department. A Development
Agreement will be required to obligate- the developer for
construction of the public improvements indicated on the
Utility Plans.
16. The Street Oversizing Fee is $584 per dwelling unit payable at
the time of building permit issuance.
17. There is significant vegetation on the southerly portion
(Strachan Farm). These trees could become a significant focal
point of the development. It is suggested that you contact
Tim Buchanan, City Forester, to evaluate future disposition of
these trees.
18. A neighborhood meeting will be required.
5. The Parkland Development Fee is $779 per dwelling unit payable
at the time of building permit issuance.
6. The site is located in the Fox Meadows Drainage Basin. The
Storm Drainage Fee in this basin is $6,468 per acre, subject
to the runoff coefficient and the amount of stormwater
detention. The flows from the development must be routed to
the outfall which is the inlet ditch for Fossil Creek
Reservoir. This may require obtaining the necessary offsite
easements.
7. At the time of submittal, a Drainage Report, Drainage and
Grading Plan, and Erosion. Control Plan are required.
8. The Stormwater Utility strongly discourages backyard drainage
systems. Experience indicates that there are numerous
problems with homeowner's understanding how these systems
work. If a backyard drainage system is to be installed, then
there must be plat notes, and other possible notices filed
with the County Clerk and Recorder to make homeowners aware of
the situation and their responsibilities. For further
information, please contact Glen Schlueter, 221-6589.
9. A traffic impact analysis will be required. The southerly
access drive should align with any possible dedicated access
on the west side of C.R.#9. Also, it may be helpful to
coordinate with Bartran Homes, developer of English Ranch, on
future filings to determine other possible street locations in
the area.
10. It is recommended that the cul-de-sac on the north be
connected into the Shields Farm. Although this connection may
be controversial with the neighbors, this connection is
necessary for second point of access for existing County
residents.
11. Although the southerly street may be single loaded, it may be
a good idea to make this a 36 foot wide street since it will
carry traffic to the arterial. At minimum, there should be
the 36 foot cross-section at the intersection with C.R. #9 so
a separate left turn bay may be provided.
12'. The necessary street and utility dedications must be made
adjacent to C.R. #9, classified as an arterial street.
13. The developers are encouraged to contact N.C.R. to coordinate
street improvements on C.R. #9. Also, please be aware that
the City will be constructing a portion of C.R. #9, along with
bicycle lanes, this summer. Please contact Mike Herzig, 221-
6750, for details on this project.
14. The arterial section along C.R. #9 should be designed and
included in the Utility Plans. This includes cross -sections
and centerline profiles as per City standards. For.further
information, please contact Kerrie Ashbeck, 221-6750.
CONCEPTUAL REVIEW STAFF COMMENTS
MEETING DATE: May 31, 1994
ITEM: Shields/Strachan Farms
APPLICANT: Everitt Companies (Shields Farm), and Paul Ross
(Strachan Farm) c/o Eldon Ward, Cityscape Urban Design, 3555
Stanford Road, Suite 105, Fort Collins, CO. 80525.
LAND USE DATA: The two farms combine to represent 135 dwelling
units on 35.25 acres, located on the east side of County Road #9,
north of Hewlett-Packard.
COMMENTS:
1. The City of Fort Collins Light and Power Department may have
difficulty in serving the site. Presently, there are
electrical facilities on the north side of Horsetooth Road,
approximately 1,800 feet west of the intersection of County
Road #9. Another possible source of power would be duct bank
on the north side of Harmony Road. The problem with the
Harmony source is that the right-of-way for C.R. #9 does not
have any available space for additional underground utilities.
In addition, the existing vegetation on the east side of C.R.
#9 may cause a problem in allowing a suitable location for
underground facilities. From either source, there is a
considerable distance to the site. For further information,
please contact Janet Perry, 221-6700.
2. There is a 24 inch diameter water line and a 24 inch diameter
sewer line in C.R.#9 that can serve the site. Repays are due
on both lines. Mains can be extended from C.R. #9 down the
local streets. A water main needs to extend into the easterly
cul-de-sac to serve the subdivision to the east. For further
information, please contact Roger Buffington, 221-6681.
3. Patio homes or duplexes on their own lots which have a zero
lot line or attached side wall must comply with building
separation requirements of the Uniform Building Code, as
amended by the City of Fort Collins. Please contact Sharon
Getz, Plans Examiner, 221-6760, for further information.
4. All homes must be within 400 feet of a fire hydrant capable of
delivering a minimum of 1,000 gallons per minute with 20 psi
residual pressure. Be sure that all exterior portions of the
patio homes are within 150 feet of an approved fire access
roadway.
COMMUNITY PLANNING &
ENVIRONMENTAL SERVICES 281 NORTH COLLEGE P.O.BOX 580 FORT COLLINS, COLORADO80522-0580 (303)221-6750
PLANNING DEPARTMENT
00 Comma y Planning and Environmental Mces
Planning Department
City of Fort Collins
June 2, 1994
Everitt Companies
Paul Ross
c/o Cityscape Urban Design
3555 Stanford Road, Suite 105
Fort Collins, Co 80525
Dear Eldon:
For your information, attached is a copy of the Staff's comments concerning
Shields/Strachan Farms, presented before the Conceptual Review Team on May 31,
1994.
The comments are offered informally by Staff to assist you in preparing the
detailed components of the project application. Modifications and additions to
these comments may be made at the time of formal review of this project.
If you should have any questions regarding these comments or the next steps in
the review process, please feel free to call me at 221-6750.
Sincerely
Ted Shepard, AI
Senior Planner
TS/gjd
Attachments
cc: Transportation Department
Stormwater Department
Project Planner
File
281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6750