Loading...
HomeMy WebLinkAboutROBERT SHIELDS 2ND ANNEXATION & ZONING - 19-94D, E - CORRESPONDENCE -subdivision. The drainage facilities must not impact the Thomas property to the south. For further information, please contact Glen Schlueter or Basil Hamden, 221-6589. 6. The Parkland Development Fee is $813 per unit payable at the time of building permit issuance. The Engineering Department will require the submittal of Utility Plans. A Development Agreement will be prepared obligating the developer to construct the improvements as described on the Utility Plans. Work cannot begin on the project until the plat is recorded, the Utility Plans are approved by the City, and the Development Agreement is signed by all the parties. 8. The Street Oversizing Fee is $584 per unit, payable at the time of building permit issuance. 9. Please consider an access easement between Lots three and Four for pedestrian access to the east and for maintenance of the stormwater detention pond. 10. Please indicate that the Nussbaumer M.R.D. is now the Wild West Annexation, zoned R- L-P, Low Density Planned Residential (upper case - no P.U.D. condition). 11. With the requirements for Utility Plans, Drainage Report, Development Agreement, the request may not be eligible for a Minor Subdivision process. Since the request is for new development in a sensitive area, the request may be forwarded to the Planning and Zoning Board. It is suggested that we further discuss the submittal process. 12. The site is bordered on two sides by large -lot single family homes located in the County. Based on citizen input regarding Woodland Park P.U.D., the surrounding neighborhood is very concerned about future development in the area. Therefore, a neighborhood meeting will be required. For the sake of efficiency, it is suggested that the proposed church on the Wild West site also be featured at the neighborhood meeting. CONCEPTUAL REVIEW STAFF COMMENTS MEETING DATE: July 10, 1995 ITEM: Robert Shields Subdivision APPLICANT: Mr. Robert Shields and Ilene Shields c/o Eldon Ward, Cityscape Urban Design, 3555 Stanford Road, Suite 105, Fort Collins, CO. 80525. LAND USE DATA: Request for a six lot subdivision on approximately six acres located east of County Road #9, north of Hewlett-Packard, east of Woodland Park P.U.D. COMMENTS: 1. Electrical power will be supplied through Woodland Park P.U.D. There will be problems if the requested subdivision develops out of sequence with Woodland Park. The deep lots with the potential of large front setbacks will be charged more due to the length of electrical service to the house. For further information, please call Janet McTague, 221- 6700. 2. A water main is available to serve the site on the eastern part of Woodland Park P.U.D. As with electrical service, the deep lots will require special consideration. Water service curb boxes and meter pits will be required to be placed out in front by the right-of-way. 3. The available sanitary sewer is very shallow. These six lots will require sewage ejection pumps since there may not be sufficient gravity flow. A shallow sewer may require special treatment for insulation and backfill and compaction. For further information regarding water and sewer issues, please contact Roger Buffington, 221-6681. 4. It appears that Lots 2 and 5 may require automatic fire sprinkler systems. Such systems must be installed in accordance with the specifications (separate services, backflow preventers) of the Water Department and the Poudre Fire Authority. Please contact Roger Frasco, Poudre Fire Authority, 221-6570 for further details. 5. A straight subdivision will still require the submittal of a Drainage Report, Drainage and Grading Plan, and Erosion Control Plan. Obviously, the drainage and grading of the six lots should be compatible with the design for Woodland Park P.U.D. Drainage easements may be necessary if the detention pond is located outside the limits of the six lot COMMUNITY PLANNING & ENVIRONMENTAL SERVICES 281 NORTH COLLEGE P.O.BOX 580 FORT COLLINS, COLORADO 80522-0580 (303)221-6750 PLANNING DEPARTMENT Commur' • Planning and Environmental c -vices Current Pla►.ning July 10, 1995 Mr. & Mrs. Robert Shields c/o Eldon Ward, Cityscape Urban Design 3555 Stanford Road, Suite 105 Fort Collins, CO 80525 Dear Eldon: For your information, attached is a copy of the Staff's comments concerning Robert Shields Subdivision presented before the Conceptual Review Team on July 10, 1995. The comments are offered informally by Staff to assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 221-6750. Sincere Ted hepard, AICP Senior Planner TS/gjd Attachments CC: Transportation Department Stormwater Department Project Planner File 281 North College Avenue • P.O. Box 580 Fort Collins, CO 80522-0580 • (970) 221-6750 FAX (970) 221-6378 TDD (970) 224-6002