HomeMy WebLinkAboutTHE DETAIL CENTER PUD - PRELIMINARY & FINAL - 22-94 - CORRESPONDENCE - STAFF'S PROJECT COMMENTSPROJECT [- "A COMMENT SHEET City of Fort Collins DATE: 5 Apri11994 DEPARTMENT:�,� PROJECT: 22-94 THE DETAIL SHOP PUD - P/F PLANNER: Steve Olt Please respond to this project by Friday, April 15,1994. No Problems Problems or concerns (see below) Review of these plans should not be construed as a commitment that telephone facilities sufficient to serve this project are presently available. U S WEST will provide telephone service in accordance with the. rates and tariffs on file with the Colorado Public Utilities Commission. The owner is responsible for provision of all conduit, ditch, and street crossings for telephone facilities within the project, and the owner provides terminal room space and power for the main terminal at one building, generally in a janitors' closet or utility room. The owner's vendor provides all facilities beyond the main terminal. Contact the U S WEST. engineer for conduit specifications for the main telephone entrance cable. Relocation of existing telephone facilities required by these plans will be paid for by the developer. Susan M. Peterson Manager Network & Technology Services 303-224-7473 Date: y -,;2 Signature: 0 PLAT CHECK IF YOU WISH TO RECEIVE SITE COPIES OF REVISIONS: LANDSCAPE L� UTILITY COMMUNITY PLANNING & ENVIRONMENTAL SERVICES 281 NORTH COLLEGE P.O.BOX 580 FORT COLLINS, COLORADO 80522-0580 (303)221-6750 PLANNING DEPARTMENT This completes the review 'comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please be aware of the following dates and deadlines to assure your ability to stay on schedule for the May 23, 1994 Planning and Zoning Board hearing: ****************************************************************** Plan revisions are due by 5:00 p..m. on May 5, 1994. Please contact me for the number of folded revisions required for each document. PMTIs, renderings, and 8 folded copies of final revisions (for the Planning and zoning Board packets) are due by 3:00 p.m. on May 16, 1994. ****************************************************************** Please contact me at 221-6750 if you have questions or concerns related to these comments. I would like to schedule a meeting with you as soon as possible, if necessary, to discuss these comments. S' rely, e Olt Project Planner xc: Ron Phillips Kerrie Ashbeck Advance Planning Stormwater Utility Transportation Parks & Recreation file/Project Planner f. 8. Is the building to be equipped with an automatic fire sprinkler system? If not, then the entire building must be within the maximum of 150' distance for emergency access to all exterior points on the building. There must also be a 20' wide unobstructed driveway around the building. The entry drive is only about 15' wide and the driveway on the north and west sides of the building is only 12' wide. This is not adequate. Questions about fire prevention and emergency access should be directed to Mike Pretz of the Poudre Fire Authority. Mike can be reached at 221-6570. 9. The utility plans are incomplete as submitted. As a minimum, dimensions are needed throughout the plans. An erosion control plan,is required and was not submitted. The detention area needs to be verified. Please contact Mike Herzig or Kerrie Ashbeck of the Engineering Department if you have questions about these comments. They can be reached at 221-6750. 10. There appears to be a lot of unnecessary pavement proposed on this site. How are the autos going to enter and exit your building? Is the amount of parking shown on the Site Plan necessary for your business? How is the handicapped access parking space shown on the north side of your building going to work? 11. The Landscape Plan needs lots of work. It is difficult to read the plan and understand what is where. Russian Olive trees are not an acceptable tree in the City of Fort Collins. There is a City -approved street tree list available from the City Forester or the Planning Department. There should be street trees along McClelland Drive, and you could possibly incorporate them into earth berms to provide a better visual buffer from the street. 12. The whole drawing is difficult to read and understand. The line weight differentation is not good, making it hard to know what is what. 13. The surrounding land uses must be identified on the Site Plan, for 150' in all directions. 14. An Air Pollution Emissions Notification (APENS) may need to be filed with the State Department of Health if there is going to be a spray booth. Check with Myrna Hansen of the Larimer County Environmental Health Department at 498-6789. 15: Bicycle racks should be provided for this use. 16. The plans are not complete enough for final approval without significant conditions relating primarily to utilities. It is recommended that this proposal continue as a preliminary request only. Commur' • Planning and Environmental vices Planning Department City of Fort Collins April 22, 1994 Butch Stockover 1849 Ramsgate Court Fort Collins, CO. 80524 Dear Butch, Staff has reviewed your documents for the Detail Center that were submitted on March 31, 1994, and would like to offer the following comments: 1. This site -is part of Lot 3 of the Replat of the Swallow Subdivision that is on record in the City. It is not necessary to replat this property unless additional utility, drainage, and/or public access easements (other than what are on the existing plat) are required for this use. If additional easements are necessary, then a replat could be, done or deeds of dedication (certified by an attorney) could.be prepared, approved, and recorded. 2. The access point into the site from West Swallow Road should be at 90 degrees to the street. 3. Public Service Company has stated that the utility easements adjacent to Swallow Road and McClelland Drive need to be wide enough such that the distance from the back of the sidewalks to the rear line of the easement is 13' wide. No trees are to be planted within 4' of gas mains. 4. A copy of the,comments received from U.S. West is attached to this letter. 5. The Water/Wastewater Department has indicated that their comments are on a red -lined utility plan that has been forwarded to your engineer. Please contact Roger Buffington if you have any questions about water and sanitary sewer services. Roger can -be reached at 221-6681. 6. The dimensions of the parking stalls must be indicated on the Site Plan. The building setbacks from the property lines must also be indicated on the Site Plan. 7. A copy of the comments received from the Building Inspection Department is attached to this letter. Please contact Sharon Getz if you have questions about the Building Code requirements. Her telephone number is on the comment sheet. 281 North College Avenue • P.O. Box 380 • Fort Collins, CO 80522-0580 • (303) 221-6750