HomeMy WebLinkAboutHARMONY SAFEWAY, CENTENNIAL BANK - FDP - 33-94D - SUBMITTAL DOCUMENTS - ROUND 1 - TRAFFIC STUDYMr. Dennis Wyatt
Wyatt & Associates, P. u.
-ebruary 23, 1999
Page 2
Land Use
Units
GroceryStore 48 KSF
Retail
40.3 KSF
Restaurant
12 KSF
Fast Food
3.8 KSF
Bank
4.6 KSF
Daycare
6.6 KSF
TABLE 2
TRIP GENERATION
FROM APPROVED TRAFFIC
STUDY
ITE
AM Peak
Hour
PM
Peak
Hour
Code
ADT in out
Total
in
out
Total
850
4,960 67 29
96
253
243
496
814
1,639 124 134
258
113
86
199
832
2,134 91 87
178
87
68
155
834
2,698 108 104
212
72
67
139
912
1,220 29 22
51
96
105
201
565
523 46 40
86
42
48
90
13,174 465 416
881
663
617
19280
If you have any questions please contact me.
Sincerely,
Kathleen L. Krager E.
Transportation Engineer
Krager and Associates, Inc.
1390 Stuart Street, Carriage House
Denver, Colorado 80204-1243
(303) 446-2626 FAX 1303) 446-0270
February 23, 1999
Mr. Dennis Wyatt
Wyatt & Associates, P.C.
1865 S Pearl St.
Denver, CO 80210
RE: Harmony Center Marketplace
5901dw1.wps
Dear Dennis:
Per your request I have analyzed the Trip Generation potential of the revised land
uses for the Harmony Safeway Center. The revised project Trip Generation is shown in
Table 1. Table 2 illustrates the Trip Generation projections that were approved in the
Traffic Impact Study for this site. As you can see from the two tables the project
specific users will generate less traffic than the land uses assumed in the Traffic Impact
Study.
Grocery
48.3 KSF
Retail
56.1 KSF
Bank W.D.T. 6.0 KSF
Restaurant
5.0 KSF
Day Care
6.0 KSF
TOTAL
TABLE 1
REVISED TRIP GENERATION
ITE CODE
ADT
IN
OUT
TOTAL
850
5,386
284
272
556
814
2,282
62
83
145
912
1,591
42
34
76
832
652
33
21
54
565
476
37
42
79
10,387
458
452
910