HomeMy WebLinkAboutHARMONY SAFEWAY MARKETPLACE, LOT 8 - PDP - 33-94G - CORRESPONDENCE - FIRE AUTHORITY REQUIREMENTS (3)LOCATION OF
FIRE NYDRAr
FIRE TR�-
M /A ' = A I"111 1 G
r
SISIL.
C
Cahen Architectural Group P.C.
TRANSMITTAL LETTER
Date:
8/28/02
To:
Poudre Fire Authority
Ron Gonzales
(970) 221-6635 - Fax
From:
Jim Tanner
Re:
Fort Collins 9,900 Retail
Job No.:
22807
N
WE ARE SENDING THE FOLLOWING: 3 VIA: Fax
COPIES
DATE
NO.
DESCRIPTION
1
08/28/02
See remarks below
THESE ARE TRANSMITTED AS CHECKED BELOW:
For Approval
Approved as Submitted
For Your Use
Approved as Noted
XXX
For Review and Comment
Approved as Corrected
As Requested
No Exceptions Taken
Submit copies for distribution
Resubmit copies for approval
REMARKS:
I did a study on the two issues we talked about yesterday. The best turn radius I could
get was 15' inside radius and a 35' outside radius. As you can see on the attached
sketch, the on -site turning movement adversely affects the site plan. We then looked at
parking two fire trucks on the street and found out that the two fire trucks can service
the building with an approximate 20' of overlapping hose. Since the building is fully
sprinkled, an the fact that your hose length rule will provide full access from the
adjacent streets, we do not see the need for the on -site movement.
Please review and send me back your comments.
Thanks.
Jim Tanner
Extension 213
COPY TO
SIGNED
TWO TAMARAC, 7535 East Hampden Avenue, Suite 425, Denver, Colorado 80231 6 (303) 743-0002 ■ (303) 743-0005 FAX