Loading...
HomeMy WebLinkAboutHARMONY SAFEWAY MARKETPLACE, LOT 8 - PDP - 33-94G - CORRESPONDENCE - STAFF'S PROJECT COMMENTS (3)Show and label location of meter pit and curb stop on the overall utility plans. Draw meter pit to scale. Curb stop must be within a utility easements and meter pit may not be located in a hard surface (Le. asphalt, concrete). Number: 32 Created: 1/22/2003 See site, landscape and utility plans for other comments. Department: Zoning Issue Contact: Jenny Nuckols Topic: General Number: 40 Created: 2/3/2003 Please remove topo lines from final site and landscape plans Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Yours Truly, Ted Shepard City Planner Page 3 approved roadway. Each hydrant must be capable of delivering 1500 gallons of water per minute at a residual pressure of 20 psi. 97 UFC 901.2.2.2 Number: 36 Created: 2/3/2003 STREET NAMES: Street names shall be verified and reviewed by City Planners prior to being put into service. 97 UFC 901.4.5 Number: 37 Created: 2/3/2003 BUILDING AREA: These proposed buildings exceed 5000 square feet and must be fire contained or fire sprinklered. 97 UBC Table 9B NOTE: This requirement pertains to the First Bank (5,468 sq. ft.) and Retail "A" (7,700 sq. ft.) Number: 38 Created: 2/3/2003 SPRINKLER REQUIREMENT: This proposed building shall be fire sprinklered. NOTE: This requirement pertains to the King Soopers building (66,283 sq. ft.) and Retail "C" (10, 160 sq. ft.) Number: 39 Created: 2/3/2003 KNOX BOX: Poudre Fire Authority requires a "Knox Box" to be mounted on the front of every new building equipped with a required fire sprinkler system or fire alarm system. 97 UFC 902.4; PFA policy 88-20 Department: Stormwater Utility Issue Contact: Wes Lamarque Topic: Drainage Number: 42 Created: 2/4/2003 Please revise the table with the C-factor comparisons to either be both 100-year C- factors or both 10-year C-factors. Number: 43 Created: 2/4/2003 The time of concentration value for basin N-18 seems a little high considering the area was reduced from the original N-18 basin. The Tc should have reduced rather than increased. Please revise. Department: Transportation Planning Topic: General Number: 41 No further comments Department: Water Wastewater Topic: Utility Plans Number: 31 Issue Contact: Mark Jackson Created: 2/4/2003 Issue Contact: Jeff Hill Created: 1 /22/2003 Page 2 r I� 4dW STAFF PROJECT REVIEW City of Fort Collins CAHEN ARCHITECTURAL GROUP Date: 2/5/2003 CRAIG CAHEN 7535 E. HAMPDEN AVE. #425 DENVER, CO 80231 Staff has reviewed your submittal for HARMONY SAFEWAY MARKETPLACE, PAD 8 #33-94G, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Susan Joy Topic: Drainage Number: 45 Created: 2/4/2003 The drainage appears to be running from the north and west sides of the building into the ROW. All drainage must go from BOW into the street and from BOW into the property. You may need to design a swale or a drainage pan to keep the water draining away from the building and away from the public sidewalk. Please provide enough information (spot elevations and/or contours) to properly evaluate the proposed drainage. Topic: General Number: 44 Created: 2/4/2003 The fire lane required by PFA will need to be dedicated by plat or by separate document as an emergency access easement. Department: PFA Issue Contact: Michael Chavez Topic: General Number: 33 Created: 2/3/2003 REQUIRED ACCESS: A fire lane is required. The fire lane shall be visible by painting and signage, and maintained unobstructed. 97 UFC 901.2.2.1; 901.3; 901.4.2; FCLUC Number: 34 Created: 2/3/2003 ADDRESS NUMERALS: Address numerals shall be visible from the street fronting the property, and posted with a minimum of 6-inch numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable) 97 UFC 901.4.4 NOTE: The building adjacent to Timberline road will require 10-inch numerals along Timberline Road in addition to 6-inch numerals along the fire lane side. Number: 35 Created: 2/3/2003 WATER SUPPLY: No commercial building can be greater then 300 feet from a fire hydrant. Fire hydrants are required with a maximum spacing of 600 feet along an Page 1