AUTOZONE MINOR SUBDIVISION - 34-94 - CORRESPONDENCE - STAFF'S PROJECT COMMENTS
n Please show the tie-in of proposed parking lot contours to existing contours on N. College Avenue; explain and show flows from College Avenue onto the proposed site, Show the tie-in of the berm contours to the existing in the triangular Quinlan lot on the east side of your building. Please add more flow arrows in the low relief areas to clarify flow. Specify that outfall curbs are to be used on sidewalks. Subtle grading will need special attention by the contractor, and require drainage certification. The detention pond area is part of your proposed development; include it in your runoff calculations. Show the offsite easement for the detention spillway and outlet pipe. Existing contours on the Grenz and Kechter properties appear to cause some west -to -east drainage onto your property; are these flows inclu- ded in your detention pond calculations? State whether your proposed grading will block or divert any present flows from that property? This report needs to stand on its own. ,Please provide the appropriate pages of the Simons and Assoc. that state that the cross-floodplain profile of the building does not cause a significant increase in the 100 year flood water level. .Also address the effects of moving the detention pond to tract two from the triangular tract. The finished floor on the drainage and grading plan is different than that on the floodplain use permit; does the permit need to be revised? Show the floodway easement on the plat. No plat was sent with the report and plans, please provide. Please include a rainfall performance standard and an erosion control effectiveness calculation. Provide an erosion control schedule (see attached examples from the manual). Please address the redline comments on the plans and in the report. Autozone PROJECT COMMENT SKEET DATE: 8 June 1994 DEPARTMENT: � ✓M w4,16K PROJECT: 34-94 Autozone Minor Subdivision PLANNER: Steve Olt All comments must be received by Thursday, 23 June, 1994. No Problems bdaeCasince a'uureraingchnnel is to blanket drainage easement will be needed over uthethis wholelte site. Please provide one as well as a plat with your next resubmittal. Please provide a copy of the executed offsite easement needed for Your site. The copy we have is dated September 1993 and is not signed. The Ft. Collins Drainage Criteria Manual specifies that commercial development must design capacity for onsite conveyance of the discharges resulting from 10 and 100 year storm. However, release rates to offsite are to, be at the historical Q2 with detention of the difference between the Q100 and the Qz. Please provide flow concentration/design point calculations at each curb cut, and at the entrance to the detention pond. including section views, and Q10 and Q100 flow depths. Demonstrate that the cuts and the pans are sized properly to handle these flows with the required 133% of Q100 capacity or 1 foot of freeboard. Date:/� �/5 Si4nature: CHECK IF YOU WISH TO RECEIVE COPIES OF REVISIONS: ❑ PLAT ❑ SITE ❑ LANDSCAPE ❑ L=I TY DEVELOPSIENT PLANNING DEPARTMENT 231 NORTH COLLEGE P.O.BOX 580 FORT COLLL4S, COLORADO 80522-0580 (303)221=67jo PROJECT ' City of Fort Collins COMMENT SHEET/ DATE: 8 June 1994 DEPARTMENT: PROJECT: 34-94 Autozone Minor Subdivision PLANNER: Steve Olt All comments must be received by Thursday, 23 June, 1994. © No Problems ❑ Problems or Concerns (see below) Review of these plans should not be construed as a commitment that telephone facilities sufficient to serve this project are presently available. U S WEST Communications will provide telephone service in accordance with the rates and tariffs on file with the Colorado Public Utilities Commission. The developer is responsible for providing conduit or trench for telephone facilities within the project. Please refer the developer to U S WEST Communications at (303)224-7470 or 224-7473. The developer may choose to provide joint trench for electric, television, and telephone cables. In this case the developer coordinates the placing sequence of each utility. If these plans necessitate the relocation of existing telephone facilities, the developer will pay for the relocation. Date: v 1i ) Signature: CHECK IF YOU WISH TO RECEIVE COPIES OF REVISIONS: ❑ PLAT ❑ SITE ❑ LANDSCAPE ❑ UTILITY ULVZLUri z1 I3LKVJlzz PLANNING DEPARTMENT 281 NORTH COLLEGE P.O.BOX 580 FORT COLLINS, COLORADO 80522-0580 (303)221-6750 06/2B/1334 14:32 350- _S'J CDOT REG 4 TRAFFTi-. PAGE 03 Mr. Steve Olt June 28, 1994 Autozone Minor Subdivision Page 2 of 2 these plans and a final permit at such time as the reconstruction is necessary based upon imp DR&ZNAGZ The drainage plan shows a detention system at the east and of the property, away from tha state highway. LANDSCAPING The n shows all lantings outside of the dedicated ROW. landscaping heplan plantings d not obstruct eight distance at the highway access. UT=L=T=Ma should new utility lines or connections be necessary within the state highway ROW, a utility permit will be required. prior to such utility work, Mr. Henry Rangel of the Department should be contacted at (303) 350-2111. . My comments are based upon the submittal as received June 13, . 1994. Thank you for the opportunity to review the Autozone Minor Subdivision: Please contact me at (303) 350-2163 i1 you have any questions. Sincerely, ---- rx4x-ldo (I. . /97. Tep4ba 0. Jones Region Devel ent/Access co dinator TG.7:g1 xc: D. Yost J. Springs:'_ file 06/28/1994 14:32 bc•-j0-__' CDOT REG 4 TRAFFIC PAGE 02 STATE OF COLORADO DEPARTMENT of TRANSPORTATION O7. Region 4 1420 2nd Street P.O. Box 850 Greeley. Colorado 80632-0850 (3031353-1232 Larimer County, 9H 267 Autozone Minor Subdivision S. of Jax Surplus Right Side Fort Collins dune 28, 1994 Mr. Steve Olt - Planner City of Fort Collins P.O. Box 5e0 Fort Collins, CO 80522 Dear Steve, I have reviewed ths'Autozone Minor Subdivision proposal and offer the following comments: RIOFT-OF-WAY It appears that the appropriate width of right-of-way is to be dedicated with this development resulting in 60 feet east of the highway centerline for a total of 120 feet. ACCESS This revised plan shows a single access adjacent to the south property boundary. This location is as recommended to Kerrie Aehbeok on October 8, 1993. sheet C1.0 shows a cross access with the property to the north (dax surplus)• That access is located approximately 70 feet east of sH 2e7. The Jax Surplus site configuration has not been provided, therefore, it is not possible to evaluate the relationship of this proposed cross access to the traffic patternn of that existing commercial development. The access drive is dimensioned as 30 feet, flow line to flow line. The dimensions of the gutter pan have not bean provided (sheet 1/C2.0 was not included in this submittal). Assuming a 2 foot gutter pan, the access width exclusive of curb and gutter would be 26 feet. The range of widths appropriate for this type of commercial use would be 25-35 feet exclusive of curb and gutter (The standard method of dimensioning access .is exclusive of curb and gt]tter.) sheet C1.4 shows the final access design to include 20 foot radii. This is the minimum radius recommended by the State Highway Access Code. An access profile has not been provided. However, based upon the spot elevations shown on sheet C1.4 for the curb return flow line and based upon the projected edge of asphalt, I have determined that the access slopes from the ROW line toward the highway at a 4♦ grade. That grade should be maneuverable. I suggest.that an access- profile be added to the plans for ease of review and inspection. ACCESS pBRMITTINO I =_CB6B The City and the Department should discuss the permitting process for this condition when a temporary access is to be constructed. it seems appropriate neceeeary to issue a temporary permit at this time that could include the entirety of 12. As stated in Section 29-644(7) of the City Code, the applicant shall provide a list of all affected property owners within a minimum of 500 feet of the proposed subdivision (in all directions) for the purpose of enabling the City to mail notification letters of the administrative public hearing to these property owners. Has this been submitted to date? This completes the City staff's comments at this time. Please contact me at (303) 221-6750 if you have questions. S 7 19 0 "1t ect Planner cc: Bob Blanchard, Chief Planner Kerrie Ashbeck Jehn & Associates, Inc. 6. The City Mapping/Surveying Department has asked if Lots 2 & 3 have access to a public right-of-way or access easement. A legal lot must have frontage on a dedicated public street. would it be better to plat this as a one lot subdivision with necessary easements granted for drainage, access, utility, etc? 7. Because of the nature of this business, a Hazardous Material Impact Analysis will be required. Please contact Ron Gonzales of the Fire Prevention Bureau of the Poudre Fire Authority for assistance with this analysis. He can be reached at (303) 221-6570. 8. There may be a potential that this site has contaminated soils from leaking underground storage tanks. Please check with Rich Grossman at the Larimer County Environmental Health Department to see if there is a concern. He can be reached at (303) 498- 6775. 9. A copy of the comments received from the Stormwater Utility is attached to this letter. Please contact Basil Hamdan if you have questions about the comments. He can be reached at (303) 221-6589. 10. The comments received from the Engineering Department are as follows: a. The utility plans need some more work to clarify what is being built along North College Avenue in the interim, how it will drain, etc. b. Provide a centerline profile of the driveway to show how it ties into North College Avenue. C. The potential for shared access or cross -access with the property to the south should be planned for. Is shared cross -access to the north being constructed now? d. Please fill out the Application for State Highway Access Permit for a new temporary driveway. On either the Site Plan or a utility plan sheet (preferably both), show how the Jax site circulation ties into this site and where their drive aisles are located. Please contact Kerrie Ashbeck if you have questions about these comments. She can be reached at (303) 221-6750. 11. The City Zoning Department is reviewing the Site and Landscape Plans for this request since it has been submitted as a permitted "use -by -right" in the HB, Highway Business Zoning District. Please contact Peter Barnes or Dan Coldiron if you have questions about the review of these plans. They can be reached at (303) 221-6760. ON I City of Fort Collins Comma_ _,y Planning and Environmental ervices Planning Department July 20, 1994 Lou Ellis AUTOZONE Inc. 3030 Poplar Avenue Memphis, Tennessee 38111 Dear Mr. Ellis, �j�r�rir, Staff has reviewed your submittal documents for the AUTOZONE Minor Subdivision that were submitted to the City and would like to offer the following comments: 1. A copy of the letter received from the Colorado Department of Transportation is attached to this letter. 2. A copy of the comments received from U.S. West is attached to this letter. 3. Public Service Company of Colorado has stated that they need utility easements to get through Lot 1 and into Lots 2 & 3. A redlined copy of a portion of the subdivision plat,'showing the locations of these easements, is being sentto your engineers. Also, no trees can be located within 4' of gas lines. 4. The City Light & Power Department has stated that they need 2 6' wide utility easements that must be recorded on the subdivision plat. A redlined copy of a portion of the plat, showing the locations of these easements, is being sent to your engineers. Also, the domestic water line needs to be relocated from its present location. From the beginning, Light & Power has told the owners that a 3-phase electric line has to go in that location ... and it still does! Please contact Bruce Vogel of Light & Power if you have questions about these comments. He can be reached at (303) 221-6700. 5. The City Water/Wastewater Department included comments on redlined copies of the utility plans; being reviewed by the Engineering Department, and redlined copies of the Landscape Plan, being reviewed by the Zoning Department. They have a minimum separation requirement from water services of 10' for trees and 4' for shrubs. Please contact Roger Buffington if you have questions about these comments. He can be reached at (303) 221-6681. 281 North College Avenue - P.O. Box 580 - Fort Collins, CO B0522-0580 - (303) 221-6750