HomeMy WebLinkAboutPARK SOUTH COMMERCIAL PLAZA, LOT 2B, AUTAWASH - PDP - 37-94B - CORRESPONDENCE - STAFF'S PROJECT COMMENTS (3)6) Please show the location of all transformers on the revised Site and Landscape Plans. They must be located no more than 10 feet from a paved surface and must be screened from view. 7) As noted on Sheet 3 of 5, provide a detailed light plan (spec. sheet for all wall and pole mounted fixtures) insuring that all lighting apparatuses are shielded down, which meets the Section 3.2.4 including Section 3.2.2. 8) Verification of the irrigation system connection points to ensure all landscaping is continuously maintained per Section 3.2.1 [J]. 9) All signs will require an additional sign permit outside this comment review. 10)Please note all exterior mechanical devises, meters, et cetera, must be screened. 11)Please return all redlined documents with plan revisions. 12)Coordinate the sidewalk system through out the development with Transportation Planning Services. Additional comments and the required number of revised plans may be forthcoming as the various departments and reviewing agencies continue to review this request. Please provide a written response to each of the above comments with the submittal of plan revisions. In addition, a revised site development plan drawn to scale which is clearly dated and labeled shall be submitted to address the above. Please contact me at 970.221.6750 if you should have any questions or concerns related to these comments. . Sincerely, Ronald G. Fuchs City Planner cc: Bob Mechels . Dave Stringer Transportation Planning Stormwater Poudre Fire Authority Zoning Department Current Planning File #37-94A CAMy Documents\Planning DocumentWutawash #37-94B LUClautawash first filing comments.doc 6 or connecting walkway (basically all of your facades) can have a blank uninterrupted length exceeding 30 feet without including at least two of the following: change in plane, change in texture or masonry pattern, windows, treillage with vines, or an equivalent element that subdivides the wall into human scale proportions. If you don't want to put in windows on the west facade because of the nature of the use of the building, you may include false windows and/or door openings defined by frames, sills and lintels, or similarly proportioned modulations of the wall. • It appears that the proposed design is proposing inferior materials to the rest of the building on the west facade. This section of the code prohibits use of inferior materials for side and rear facades, and specifies that all sides of the building shall include materials and design characteristics consistent with those on the front. g) Section 3.5.3(D)(3) specifies that facades that face a street or connecting walkway (all of the facades on this proposed building) must be subdivided and proportioned using features such as windows, entrances, arcades, arbors, awnings, treillage with vines, etc. along no less than 50% of the facade. You western and northern facades fall short of this requirement. Your smaller accessory buildings must also adhere to this requirement. h) Section 3.5.3(D)(6) specifies that all facades shall have a recognizable "base," and "top" treatments. A "base" treatment consists of (but is not limited to): thicker walls, ledges or sills; integrally textured materials such as stone or other masonry; integrally colored and patterned materials such as smooth -finished stone or tile; lighter or darker colored materials, mullions or panels; or planters. A "top" treatment consists of (but is not limited to): cornice treatments, other than just colored "stripes" or "bands," with integrally textured materials such as stone or other masonry or differently colored materials; sloping roof with overhangs and brackets; stepped parapets. i) The doors you propose on the west and south elevations do not have sufficient aesthetic articulation. Please incorporate these doors into the facade treatment elements described above. j) Please indicate all building colors (stone, bricks, etcetera) on the Building Elevations in accordance with Section 3.5.1(G) of the Land Use Code. k) Please indicate all building dimensions, including doors, windows, etcetera, on the building elevations. 1) Please clarify the alternate marquee as noted on the east building elevations. m) Scaled design elevations for the lube center, trash enclosure, and canopies need to be submitted and must be compatible with the overall development based upon Land Use Code standards. E b) Section 3.5.1(F)(3)(c) requires that windows must be placed to visually establish human scale and proportion and must be individually defined with detail elements such as frames, sills and lintels. Pedestrian scale/human scale is defined in Section 5 of the code as "the proportional relationship between the dimensions of a building or building element, street, outdoor space or streetscape element and the average dimensions of the human body, taking into account the perceptions and walking speed of a typical pedestrian. It appears that the window types and placements that you have proposed do not meet these requirements. c) Section 3.5.1(J)(2) requires that any wall mounted utility meters and rooftop or ground mounted mechanical equipment shall allow the architectural design to be continuous. These functions must be screened from view from adjacent properties and public streets by materials that are not inferior to the principal materials of the building and landscape. Please specify where the utility meters and mechanical equipment will be located, and show proper screening measures. Roof top mechanical must be hidden from view by a parapet. d) Section 3.5.3(C) of the LUC requires that all facades of your building cannot exceed a height: width ratio or 1:3 without substantial variation in massing that includes a change in height and a projecting or recessed element. The change in mass that is required shall be part of the integral structure of the building and not merely a tacked -on cosmetic effect. Your building as proposed is in serious violation of this standard particularly on the east, west and north elevations. e) Section 3.5.3(D)(1) of the LUC specifies that in the case of multiple building developments, each individual building shall include predominant characteristics shared by all buildings in the development so that the development forms a cohesive place within the community. Similar architectural features should be carried over from the main building to the design of the smaller buildings. f) Section 3.5.3(D)(2) of the LUC specifies minimum wall articulation that must be achieved on all facades. • The proposed design does not provide the proper architectural features to visually establish the required minimum 30 foot spaced buildings. The bays shall be established by architectural features such as columns, ribs or polasters, piers and fenestration pattern. The proposed design shows vertical bands of a different masonry surface every 30 feet, which does not satisfy the requirement. • The proposed design does not provide enough facade articulation on several facades. This section of the code specifies that in order to add architectural interest and variety and to avoid the effect of a single, long or massive wall with no relation to human size, no wall that faces a street 4 c) After revising the site/landscape, please make sure the minimum species diversity is provided in accordance with Section 3.2.1(D)(3) of the Land Use Code. d) Please note LUC Section 3.2.1(E) (4) Parking Lot Perimeter Landscaping (b) addresses the need to screen parking areas. e) Address all visual clearance and sight distance triangle areas per Section 3.2.1(L) of the Land Use Code. f) Per Section 3.2.2(M) and Section 3.2.1(E)(4) — (6) requires at least six (6) percent of the interior space of any parking lot be devoted to interior parking landscaping. The actual interior parking lot landscaping percentages have not been shown. g) All parking lots need to meet the parameters addressed in LUC Section 3.2.1(E)(5)(a) — (e) including 3.2.2(B)(5)(a) walkways shall have one (1) canopy shade tree per forty (40) lineal feet of walkways planted in a landscape, strip within five (5) feet of such walkway. h) According to Section 3.2.2(C)(3) site amenities such as benches, bike racks, et cetera should be provided. Please show site amenities. i) Section 3.2.2(C)(5) — (6) and 3.2.2(D) — (E) requires that six-foot walkways within the site provide direct well direct well-defined and separated circulation routes for vehicles, bicycles, and pedestrians. In accordance with Section 3.2.2[C][5]-[6] and [E][5] of the Land Use Code, onsite pedestrian systems should provide directness, continuity, safety and minimize the number of driveway and drive aisle crossings. These standards have not been met on the site plan, within the area to the west of building connecting it to Horsetooth. A direct pedestrian linkage shall be provided on the south property line adjacent to the private drive. The parking and circulation system should accommodate the movement of vehicles, bicycles, pedestrians and transit safely and conveniently throughout the site and to and from surrounding areas. The drive aisle widths into the private drive should be reduced in size. 5) The following comments apply to the architectural design of the building: a) You have not specified the opacity of the glass you are proposing. Section 3.5.1(F) of the LUC specifies that clear glass (reflectivity or opacity of less than 60%) shall be used for commercial storefront display windows and doors. Please specify. 3 G. Water/Wastewater: submitted a response to the checklist and is attached to this report. H. Light and Power: submitted the response and it is attached to this report. Street Oversizing: submitted a checklist that identified several requirements. Their response is attached to this report. J. Poudre Fire Authority: submitted a checklist that identified several requirements. Their response is attached to this report. K. Building Inspections Department: their response is attached to this report. L. Stormwater: submitted a checklist that identified a number of requirements. Their response is attached to this report. M. Engineering: submitted a checklist that identified several requirements. Their checklist is attached to this report. N. Transportation Planning: submitted a checklist that identified several requirements. The checklist is attached to this report. O. Zoning Department: submitted a checklist that identified their requirements. Their response is attached to this report. P. Current Planning Department: provides the following: 1) An amendment needs to be submitted and approved prior to approval of 37-94B to accommodate any off -site alterations and changes that need to occur to accommodate this development. 2) Delineate all property line setbacks, Horsetooth right-of-way width, private drive widths, and sidewalk widths on all plans. 3) The gross acreage and net acreage figures are different, does net acreage figure factor Horsetooth right-of-way dedication? 4) The following comments apply to the Site/Landscape Plan: a) The gas pumps will need to be re -located out of the easement. b) Per LUC Section 3.2. 1 (E)(4)(a) parking lot perimeter landscaping asks that trees be provided at a ratio of one (1) tree per twenty-five (25) lineal feet along a public street. Per LUC Section 3.2.1(D)(2) street trees shall be placed at thirty-foot to forty -foot spacing intervals in the center of all parkway areas. The trees shall be placed at least eight (8) feet away from the edges of driveways and alleys, and forty feet (shade trees)/fifteen feet (ornamental trees) (LUC 3.2.1(K) from any street light. 2 Comm- 'ty Planning and Environmental rvices Current Planning City of Fort Collins FLE COPY June 9, 1999 Mr. Barry Hillegas P.O. Box 3558 Englewood, CO 80155 RE: Autawash Dear Mr. Hillegas: This letter is in response to plans for Park South Commercial Plaza, Lot 2-B Autawash Project Development Plan (City File #37-94B) submitted on May 11, 1999. Please note that staff reviewed your plans and the Planning Division mailed a request for comments to several public agencies and departments. This development proposal is subject to and shall comply with all requirements set forth in the City's Land Use Code (LUC), specifically: Articles 2. Administration (Development Review Procedures); Article 3. General Development Standards; and, Article 4. [Zoning] Districts. The City of Fort Collins Land Use Code (LUC) requires that throughout all land use proceedings, the burden to comply with all applicable standards rest with the applicant. Staff, after reviewing materials submitted by the applicant, finds that revisions/re-design to the submitted plans dated 5.11.99 are warranted to meet the Land Use Code. The following lists the agencies and departments that responded and the substance of their comments: A. Public Service: the checklist is attached to this report. B. Mapping/Drafting: submitted a response to the checklist and it is attached to this report. C. Water Conservation: submitted a response to the checklist and is attached to this report. D. Post Office: submitted a response to the checklist and is attached to this report. E. TCI: submitted a response to the checklist and it is attached to this report. F. Traffic Operations: submitted a response to the checklist and it is attached to this report. 281 North College Avenue • PO. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020