HomeMy WebLinkAboutPARK SOUTH COMMERCIAL PLAZA, 2ND FILING, LOT 2B, CARWASH - PDP - 37-94E - CORRESPONDENCE - STAFF'S PROJECT COMMENTS (4)Water/Wastewater: 1. The development plan does not provide sufficient cover over the water and sanitary sewer services. Natural Resources: 1. Please contact Doug Moore, at 224-6143, for information on a trash enclosure that can be designed to provide recycling. This completes staff (and outside reviewing agencies) review and comments at this time. Red -lined plan from City departments are included with this comment letter. Additional comments and red -lined plans may be forthcoming. Another round of staff review is determined to be necessary. This proposal is subject to the 90-day revision re -submittal requirement (from the date of this comment letter, being May 25, 2004) as set forth in Section 2.2.11(A) of the Land Use Code. Be sure and return all of your red -lined plans when you re -submit. The number of copies of each document to re -submit is shown on the attached Revisions Routing Sheet. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at 221-6341. Yours Truly, Steve Olt, City Planner cc: Katie Moore The Architects' Studio Jim Sell Design Current Planning File #37-94E Page 8 Department: Water Wastewater Issue Contact: Jeff Hill Topic: Landscape Plan Number: 76 Created: 5/19/2004 (5/19/041 Show all water and sewer lines and maintain the required landscape/utility separation distances on the landscape plans. Topic: Utility Plans Number: 77 Created: 5/19/2004 [5/19/041 Maintain the minimum cover over the fire line and water service as it passes through the detention pond. See site, landscape and utility plans for other comments. The following comments and concerns were expressed at staff review on May 19, 2004: Engineering: 1. Xcel Energy has a concern about the separation between their existing gas main and the proposed north face of the building in Phase One. 2. The proposed overhang into the utility easement, for the north face of the building, could be problematic. 3. There is a concern about the u-shaped fire access going from parking lot to parking lot, potentially without an emergency access easement in the existing parking lot. 4. The sheet titles need to be made consistent with one another. Transportation Planning: 1.o, Is the car wash to be an attended facility or a completely automated facility? 2. A direct pedestrian connection may be needed. 3. A bicycle rack probably is not needed for this facility. 4. Please schedule a meeting with Tom Reiff to discuss his issues, concerns. He can be reached at 416-2040. Light & Power: 1. More definition is needed for the street right-of-way and utility easements. This will have an effect on the placement of the electric transformer. Page 7 Number: 60 Created: 5/17/2004 At final design, the detention pond needs to be discussed as to what might be required due to there being two ponds connected with a culvert. The culvert might need to be sized to carry the 100-year flow for some or all the basins. Number: 61 Created: 5/17/2004 1. The notes on the plan for grading and erosion control are incorrect. Please place the latest set of notes on the plan. 2. The submittal is incomplete complete submittal is made. Department: Transfort Topic: Transportation Number: 51 No comments from Transfort Plan will be reviewed when a Issue Contact: Garold Smith Created: 5/5/2004 Department: Transportation Planning Issue Contact: Tom Reiff Topic: Transportation Number: 42 Created: 1/5/2004 [5/18/041 Same comment applies (see red lines). [1/5/04] According to the Section 3.2.2 (C.5.a) of the Land Use Code walkways that link street sidewalks to building entrances through parking lots or along drive aisles shall be a minimum 6 feet in width. This is especially important along transit routes and a planned major transit station for the Mason Transportation Corridor. Please increase the walkway along the east side of the property to a minimum of 6 feet. Also is there an opportunity for the walkway to be located so that both adjacent land uses can utilize the walk? For example, can the walk be located further to the eastern edge of the property line along the Phase II section of the parcel? Number: 43 Created: 1/5/2004 [5/18/041 A bike rack will need to be labeled and identified on the retail building proposed as Phase II of the project. It will also need to be located near the building entrances. The bike rack shown for the Phase I car wash is not required if the facility is unattended. [1/5/04] See red lines for the suggested bike rack location. Please refer to Section 3.2.2 (C.4.a,b,c) for the design of the bike rack. Also please identify and label on all plan sets for the next submittal. Number: 44 1 Created: 1/5/2004 [5/18/041 Same comment applies. An access ramp for the .handicap stalls is also required. [1/5/04] Please identify and label the handicap parking stalls on all plan sets. Page 6 Number: 9 [5/21/041 Created: 12/30/2003 (12/30/031 water Supply: Commercial No commercial building can be greater then 300 feet from a fire hydrant. Fire hydrants are required with a maximum spacing of 600 feet along an approved roadway. Each hydrant must be capable of delivering 1500 gallons of water per minute at a residual pressure of 20 psi. 1997 UFC 901.2.2.2 Number: 10 [5/21/041 Created: 12/30/2003 [12/30/031 Hazardous Materials: Corrosive, flammable liquids, reactive, or toxic materials (As defined in the Uniform Fire Code) if used, stored or handled on site must have a Hazardous Materials Impact Analysis (HMIA) completed and supplied to the Planning Department and the Fire Department (submitted to Ron Gonzales) FCLUC 3.4.5 (C) Topic: Transportation Number: 100 Created: 5/21/2004 [5/21/041 BUILDING AREA: This proposed building exceeds 5000 square feet for type V construction and must be fire contained or fire sprinklered. 1997 UBC Table 9B Department: Police Topic: General Issue Contact: Joseph Gerdom Number: 62 Created: 5/18/2004 [5/18/041 Lighting and Landscape okay for Phase 1 only. Department: Stormwater Utility Issue Contact: Wes Lamarque Topic: Drainage Number: 20 Created: 1/1/2004 [5/17/041 Stormwater is ready for hearing. Additional comments may follow at final plan review when more information is presented. Number: 22 [5/17/041 Repeat Comment Created: 1/1/2004 Please revise datum to 7-93, which is closer. Topic: Transportation Number: 59 Created: 5/17/2004 Please revise old rainfall intensity value of 8.9 in/hr. See drainage report. This value should be less than the value for the current rainfall criteria. This will slightly increase the detention requirement. The previous drainage report had the correct old rainfall intensity. Page 5 1 Number: 49 Created: 5/4/2004 [5/4/04] A fire lane is shown on the plans, but is shown only as a 'u' and isn't shown to connect to another fire lane or street. Usually an emergency access easement is required to be dedicated for fire lanes, and the EAE would connect to a public ROW or another EAE. Please work with PFA, and if they require an easement, please show it on all plans and provide a legal, sketch, and deed of dedication using the City's standard language. Please contact me if you need a copy of this language. Number: 50 Created: 5/4/2004 [5/4/04] Please match the titles on the plans; some say Lot 2-B Park South, but the utility plan says park south commercial plaza minor subdivision 2nd filing, lot 2-b. In the City's system, it is Park South Commercial Plaza, 2nd Filing, Lot 2B, Horsetooth Carwash. Topic: Transportation Number: 98 [5/21/041 Comment inserted retail building identified connecting walkway standard discuss a couple of options Created: 5/21/2004 for Tom Reiff: (5/19/041 Currently the in Phase II is not in compliance with the A follow-up meeting is requested to regarding the layout of the building. Number: 99 [5/21/041 Comment inserted f crosswalk that leads from the Auto Zone? Is it intended to Department: Light & Power Topic: Transportation Number: 52 [5/5/04] No Comments Created: 5/21/2004 or Tom Reiff: [5/19/041 Why is there a car wash to the trash enclosure for connect to the Auto Zone parking lot? Issue Contact: Bruce Vogel Department: Natural Resources Topic: General Number: 78 [5/19/04] [12/29/03] Please trash collection areas as well allow for recycling services. Department: PFA Chavez ' Topic: General Number: 8 [5/21/041 Created: 5/5/2004 Issue Contact: Doug Moore Created: 5/19/2004 consider providing adequate space at as within the trash enclosure to Issue Contact: Michael Created: 12/30/2003 [12/30/031 Address Numerals: Address numerals shall be visible from the street fronting the property, and posted with a minimum of 6- inch numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). 1997 UFC 901.4.4 Page 4 Also, please work with XCEL/PSCO to address their concerns with the building placement in relation to their gas line in the utility easement on Horsetooth. Comment from Jim DeWilde: "PSCO has an existing 4" PED gas main laying 12' into the existing 15' U.E. PSCO needs min. 3' clearance from gas main to proposed building wall. Any relocation of main would be at developer's expense." [12/30/031 Reading the conceptual review letter sent to the applicant by Current Planning, then reading conceptual review comments in the Engineering file, it appears that engineering was mis-quoted in the letter sent to the applicant. That letter stated that: "Development of this property will have to dedicate necessary additional street right-of-way (ROW) and easements behind the ROW for West Horsetooth Road. There currently is 50' of right-of-way (south of the centerline of the street) and 57.5' is ultimately required." Engineering's file comments state that the existing ROW on Horsetooth is 50' plus 12' for the right turn lane, and 7.5' of additional ROW is needed, and that the utility easement should be a total of 15' beyond the new ROW. The additional 7.51 of ROW is still required, as is the IS' utility easement behind that. 1.8.03 - Following a meeting of the Transportation Coordination group this morning, it was agreed that the City would be willing to accept ROW dedication to the back of the existing sidewalk, approximately 4' as shown on the plans, in lieu of the standard 7.5' ROW. Please note this as an approved variance on the utility plans. Variance of the utility easement width would need to meet the approval of possibly affected utilities. If a narrower utility easement is requested, please submit an 8 1/2 x 11 sketch of the area showing the proposed utility easement, and I will route it to the appropriate utilities for their approval. The utilities are given 2 weeks to respond to these requests. Number: 13 Created: 12/30/2003 (4/30/04) Repeat: [12/30/03] Please show phasing clearly, and match the utility plans to the site and landscape plan phasing. (Required for Final Compliance). Number: 16 Created: 12/30/2003 [4/30/04) Repeat: [12/30/031 Please see redlined plans and utility plan checklist for any additional comments. Number: 48 Created: 4/30/2004 [4/30/043 Building envelopes/outlines are not allowed over utility easements. Overhangs extending no farther than 2.5' into the utility easement are permissible. If this is an overhang, please clearly label it as such. Page 3 Number: 105• Created: 5/25/2004 [5/25/041 The property line for this development is not clearly shown and identified on the Site Plan. Number: 106 Created: 5/25/2004 [5/25/041 There are 2 proposed phases in this development. Where are the phase lines? Number: 107 Created: 5/25/2004 (5/25/041 Is the applicant proposing a building envelope for either or both building(s)? Number: 108 Created: 5/25/2004 (5/25/041 The information in the DRAWING LEGEND is superfluous on the Site Plan. Number: 109 Created: 5/25/2004 [5/25/041 The proposed land uses on this development plan are Minor vehicle Servicing & Maintenance (car wash) and Retail. This Site Plan needs to reflect all of the proposed land uses. Number: 110 Created: 5/25/2004 [5/25/041 One handicapped parking space will be required in Phase Two of the development. Number: 111 Created: 5/25/2004 _ [5/25/041 Apparently there is a set of steps on the AutoZone property, to the west, that end at the west property line of this development. How is that pedestrian way to be continued into this site? Topic: Utility Plans Number: 101 Created: 5/25/2004 [5/25/041 Len Hilderbrand of Xcel Energy (PSCO) offered the following comments: a. PSCO has a 4" gas main that lays 12' south of the south right- of-way line of West Horsetooth Road. b. PSCO will need a minimum 3' clearance from the gas main to the proposed building wall. C. Any necessary relocation of gas facilities would be at the developer's/property owner's expense. Department: Engineering Issue Contact: Katie Moore Topic: General Number: 11 Created: 12/30/2003 [4/30/04) Clearly label and dimension the proposed ROW for Horsetooth and the utility easement behind it on the site and landscape plans. Page 2 / rl STAFF PROJECT REVIEW City of Fort Collins Doberstein Lemburg Commercial, Inc. Date: 05/25/2004 c/o Dan Bernth 702 West Drake Road Building E, Suite B-102 Fort Collins, CO. 80526 Staff has reviewed your submittal for PARK SOUTH COMMERCIAL PLAZA, 2nd Filing, Lot 2B, HORSETOOTH CARWASH - TYPE I (LUC), and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Steve Olt Topic: Building Plans Number: 102 Created: 5/25/2004 [5/25/041 Rick Lee of the City of Fort Collins Building Department indicated that the information submitted is very limited. A pre - submittal meeting should be scheduled with the Building Department before the construction documents proceed too far. Attached are the various codes that the Building Department will enforce. Topic: Landscape Plan Number: 112 Created: 5/25/2004 [5/25/041 The proposed landscaping needs to, be re-evaluated to ensure that the required screening for the vehicular use areas and parking lots is being provided. There is a question as to whether or not some of the proposed shrubs will provide the minimum 30" height and 70% screening required in Section 3.2.1(E) (4) (b) of the Land Use Code. Number: 113 Created: 5/25/2004 [5/25/041 A 5' wide landscaped setback area is needed along the east property line of Phase Two of this development. Please see Section 3.2.2(J) of the Land Use Code. The landscaped setback area on the Landscape Plan scales to be 3.5' wide. Topic: Site Plan Number: 103 Created: 5/25/2004 [5/25/041 Gary Lopez of the Zoning Department indicated that the Site Plan still needs building dimensions for both buildings and scaled distances to at least 2 of the nearest property lines. Number: 104 Created: 5/25/2004 [5/25/041 The Site Plan does not show the full width of the proposed sidewalk along the east property line for the car wash site (Phase One). A portion of the width of the walk would be on the property to the east. Assume there is the need for an easement from that property owner to construct a portion of the sidewalk on their property. Page 1