Loading...
HomeMy WebLinkAboutPARK SOUTH COMMERCIAL PLAZA, LOTS 3A THRU 3D - FDP - 37-94D - CORRESPONDENCE - STAFF'S PROJECT COMMENTS5 Issue Contact., Katie Moore Manhattan ave plan and profile: typical section, sawcut area will need a full - depth patch, not a mill and patch. 6 Issue Contact. Katie Moore Manhattan Ave cross -sections: calculating from these cross -sections, the values for the flowline grades do not match what is portrayed on sheet 5. Near sta 5+61, the slope is nearer 0.2% than the required 0.4%. There are 4 other areas where the minimum grade is not met, as well. Please note that in a previous round of review, the concession was made to go with the smaller cross -slopes on Manhattan, but only if the minimum flowline grades were being met. Stormwater Utility g Issue Contact. Basil Hamdan Please add note on Drainage Plan that pump is to be retrofitted for water quality. Development Agreement will have language detailing this item. Be sure and return all of your redlined plans when you re -submit. If you have questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Yours ruly, T90 J NES C�yy P anner 2 of 2 STAFF PROJECT REVIEW GINO CAMPANA Date: 07/06/2001 LAND IMAGES, INC. 408 WHEDBEE ST. FT.COLLINS.CO 80524 Staff has reviewed your submittal for PARK SOUTH COMMERCIAL PLAZA LOTS 3A-3D, PDP/FC, I #37-94C/D, and we offer the following comments: ISSUES: Current Planning 7 Issue Contact: Troy Jones Coordinate revisions directly with Katie Moore. As soon as all Engineering issues have been resolved, and Katie Moore indicates to me that she is ready for mylars, bring in the mylars with all the proper applicant signatures already filled in. g Issue Contact: Troy Jones The title of the project should read the same on the plat heading, the plat project box, and the title block for the 3 page planning document set. This is not a "subdivision" or a "minor subdivision," but rather is a Project Development Plan, otherwise known as a "P.D.P." Take out all references to subdivisions in the titles. The title of the project (in all locations) should be "Park South Commercial Plaza, Project Development Plan." You can leave the subtitle if you wish, but it should not refer to a "minor subdivision" at all. I don't need to see it again, just make sure the change is made on the mylar. Engineering Issue Contact: Katie Moore Utility plan cover sheet: Please correct general notes as redlined. 2 Issue Contact: Katie Moore Plat: The line separating the utilitiy and emergency access easement and the utility easement doesn't quite connect or really separate the two easements. 3 Issue Contact: Katie Moore Overall utility plan: Please correct the relined typos. 4 Issue Contact: Katie Moore Site Plan: There are still some small areas where the building envelopes encroach into the emergency access easement. The driveway flares on the site and landscape plans do not match the utility plans. 1 of 2