HomeMy WebLinkAboutLIND PROPERTY, 2ND FILING - FDP - 39-94E - CORRESPONDENCE - STAFF'S PROJECT COMMENTSStorm Line D crosses the 8 inch sanitary line with less than 18 inches of clearance. Please provide approval from Boxelder District for this crossing. Storm Line E will only have 12' clearance from water line and 1.2 feet from sanitary. This is not ideal, but will be allowed due to the lack of alternatives. Approval from Boxelder and Elco should be provided. Please call out clearance between Line E1 and the water line. At a minimum a 12" clearance should be maintained. Please identify storm line B as privately owned and maintained. Topic: Water quality outlet box detail Number: 136 Created: 1 /6/2006 [1/6/06] The City has slightly changed the detail for the pond water quality outlet box. Please use the updated detail. A copy of the CAD drawing of this detail will be emailed to you upon request. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely: Ted Shepard Chief Planner Page 8 a copy of the recorded easement. If the easement is to be dedicated to the City provide the dedication in proper format with the application fees to the City. Whether the easement is dedicated to the City or the district the documentation will need to be provided to the City prior to or with the mylar submittal. The city will not sign the plans until all off -site easements are received. Number: 164 Created: 1 /16/2006 [1/16/06] See plans for additional comments. Department: Stormwater-Water-Wastewater Issue Contact: Basil Hamdan Topic: Ditch Company Approval Number: 106 Created: 2/1 /2005 [1/3/06] [6/7/05] [2/1/05] Please provide the City with a letter showing approval from the ditch company for releasing flows into the ditch and for building the riprap and the. outflow pipe into the Canal No.8 ditch easement. Topic: Grading Along the Canal No 8 Ditch Number: 131 Created: 1 /3/2006 [1/3/06] Our master planning department will need to look at the proposed grading along the Number 8 Canal, especially around the bend where the proposed detention pond is located to ensure that enough right of way is left in that area that would allow the future master planned improvements. [1 /6/06] Master planning has looked at the grading along the Canal, they need a distance of 50 feet clear from the existing top of bank to any of your drainage improvements, it seems that the top of bank is being moved east in some locations which will affect the channel capacity, and the detention pond encroaches into this 50 feet minimum clearance. Number: 132 Created: 1 /5/2006 [1/5/06] Clearly identify on the phasing plan with what phase each and all lines will be constructed. Topic: Grading Sheets Number: 133 Created: 1 /5/2006 [1/5/06] Please note that a lot of the line work has labels on top of it. These sheets will need to be cleaned up before they can be approved. Topic: Storm Line Alignment Number: 134 Created: 1 /5/2006 [1/5/06] If possible please maintain a 10 foot clearance between Lot 13 Block 8 and the proposed storm line in Tract G. Topic: Utility Plans Number: 135 Created: 1 /5/2006 [1/5/06] Please label all storm sewers on the utility plans. The proposed crossing of Storm Line Al and the proposed 12 inch water line should be encased. Page 7 we need another for the 2nd filing file (the files need to be complete in and of themselves). Thanks very much! Department: Engineering Issue Contact: Sheri Wamhoff Topic: Trail Number: 143 Created: 1 /16/2006 [1/16/06] Need to provide a design for the trail (plan, profile, curve data, and details). Since the trail is to be built as a part of the development the design needs to be provided at this time. The City has agreed to pay for 2 feet of the 10 foot width and the mesh and color that is added to the trail. The maintenance of the trail will be the developers/ HOA until such time as the trail is connected to the City trail system or a maximum of 10 years which ever occurs first. Number: 144 Created: 1 /16/2006 [1/16/06] A 30 foot wide Trail Easement needs to be provided for the trail. The trail should be centered in the easement except where the trail is adjacent to the ditch road and that is not feasible. In that situation the easement will be offset. The language for the Trail Easement is: City Public Trail Easement and Right -of -Way for use as a bicycle trail, pedestrian path, equestrian or other recreational use trail and reasonable accessory uses. Topic: Utility Plans Number: 138 Created: 1 /16/2006 [1/16/06] On the cover you have a note twice on the cover that the construction notes from LCUASS apply — one of these notes should indicate that the GENERAL NOTES from LCUASS apply. Number: 139 Created: 1 /16/2006 [1/16/06] Need to include the indemnification statement from the general notes on the cover sheet of the plans. "THE ENGINEER WHO HAS PREPARED THESE PLANS, BY EXECUTION AND/OR SEAL HEREOF, DOES HEREBY AFFIRM..." Number: 140 Created: 1 /16/2006 [1/16/06] Sheet CS260 —The Keystone wall must be placed at least 2 feet behind the back of the sidewalk. Make sure that is noted here and on the detail sheet CS280. Number: 141 Created: 1/16/2006 [1/16/06] Keystone wall —need the details for this design including the structural calculations. The wall will probably require a handrail along the top of the wall due to the depth and proximity to the sidewalk. Was a variance routed and granted for this wall to be within the utility easement? The installation of the wall makes the easement unusable. Are no utilities planed to be located here? NO ties or footings for the wall can extend into the right-of-way. Can this wall (this design) be built without ties? Number: 142 Created: 1 /16/2006 [1/16/06] Off -site easements by separate document need to be provided to the City for all work outside of the plated boundary. Number: 145 Created: 1 /16/2006 [1/16/06] Where are the existing easements and right-of-way for the parcel to the east? Is the proposed fire hydrant along Richards Lake Road within an easement? If not provide an easement for this - if the easement is to be dedicated to the district, just provide the city with Page 6 Number: 171 Created: 1/16/2006 [1/16/06] At the end of Thoreau need to provide an off -site temporary turnaround easement dedicated to the City. Number: 172 Created: 1 /16/2006 [1116/06] At the end of Thoreau need to provide an off -site utility easement (for the water and sewer to be extended into this area). This easement can either be dedicated to the City or to the water and sewer district. Number: 173 Created: 1 /16/2006 [1/16/06] Per the plans a grading and construction easement is needed along the eastern boundary of this site. This is not shown on the plat or the plans. Number: 174 Created: 1 /16/2006 [1/16/06] On Block 1 the tract surrounding all of the lots needs to be an access easement. Number: 175 Created: 1 /16/2006 [1/16/061 See plat for additional comments. Department: Engineering Issue Contact: Susan Joy Topic: Plat Number: 36 Created: 4/21 /2004 [1/16/06] Boundary and legal stll do not close or match. [6/15/05] Repeat comment. [4/21/04] From Technical Services: Legal and plat do not close and do not match. See redlines. Number: 97 Created: 1 /31 /2005 [1/16/06] [6/14/05] [1/31/05] Can vacate the easements by separate document or by this plat. If you choose to vacate by separate doc, then the reception numbers need to be shown on the plat. Number: 118 Created: 6/15/2005 [1/16/06] Please call Wally Muscott as it appears that you are confused about Lot and Block concept. [6/15/05] From Technical Services: All 'Blocks" must be uniquely identified by bounds and line type. We prefer lots numbered with no blocks. Topic: Site Number: 15 Created: 4/19/2004 [1 /16/06] Need to make sure that the plat and the plans match. Lot and/or tract number will probably change as the current Block layout and labeling does not meet the intent of the use of block labeling. [6/15/05] [4/19/04] Please label all tracts. The tracts that are labeled do not match the plat. Easements do not match the plat. Topic: Soils Report Number: 28 Created: 4/21 /2004 [1/16/06] Have not yet received a copy of this to my knowledge. [6/14/051 [1/31/05] [4/21/04] Please provide another copy of the Soils Report (this can be done any time from now through final compliance). We have a copy in the 1 st filing file but Page 5 Number: 161 Created: 1 /16/2006 [1/16/06] Clarion Lane — Some of the vertical curve information and which vertical curve it applies to is not completely clear. Looks as if missing information for at least two vertical curves. Number: 162 Created: 1 /16/2006 (1/16/06] Intersection details —Beachcomber and Thoreau have a elevation that doesn't match. Bowside and Clarion have an elevation that doesn't match. Bowside and Thoreau need to identify the transition length and elevation. Galewind and Thoreau missing some elevations, need to provide transition length and elevation, and have a couple elevations that doesn't match. On Clarion Lane and Richards Lake Road and Thoreau Road and Richards Lake Road intersections identify which elevations shown are existing. Topic: Plat Number: 137 Created: 1 /16/2006 [1/16/06] Comments from Technical Services: 1. Boundary and legal DO NOT close or Match. See June 05, Feb 05 and Jan 05 comments. 2. It appears that you are confused about Lot and Block. Please call Wally Muscott for explanation of concept. 3. How wa the East line SW1/4 determined? Center Section? 4. CR 52 has been changed - This is now Richards Lake Road. Number: 165 Created: 1 /16/2006 [1/16/06] Identify who the Gas easement is to be dedicated to. Whoever it is will need to sign the plat accepting the easement. Number: 166 Created: 1 /16/2006 [1/16/06] If you are going to have an irrigation easement need to identify who it will be dedicated to and what it is for and they will need to sign the plat. Number: 167 Created: 1 /16/2006 [1/16/061 The easement identified to be vacated by separate document, why not vacate it with this plat? Number: 168 Created: 1 / 16/2006 [1/16/06] Need to define a 30 foot trail easement( City Public Trail Easement and Right -of - Way for use as a bicycle trail, pedestrian path, equestrian or other recreational use trail and reasonable accessory uses.) that is centered on the trail except for where it can't be when the trail is adjacent to the ditch road and then the easement will be offset. Number: 169 Created: 1 /16/2006 [1/16/06] Need to provide and show a drainage easement crossing the exclusive Windsor reservoir easement for the drainage pipe that crosses this easement. Also will need to provide an off -site drainage easement dedicated to the city for this pipe. Number: 170 Created: 1 /16/2006 [1/16/06] Provide access easements for all locations where there is an internal trail/ path. Page 4 M Number: 150 Created: 1 /16/2006 [1/16/06] Thoreau —Need to identify how the grading at the North end of the street will tie to existing grades. How is the turnaround to be graded? Will the 3% grade be continued for some distance and then a 4:1 tie to existing grade be done? Number: 151 Created: 1 /16/2006 [1/16/06] Thoreau — sheet CS501 — need to station the private drive (west side) and identify the width of this driveway. Add the notes that are on sheet CS503 to this sheet. Number: 152 Created: 1 /16/2006 [1/16/06] Thoreau — what is the centerline radius? Missing some driveway stationings. Number: 153 Created: 1 /16/2006 [1/16/06] Beach Comber— Identify the driveway station location and width. Provide inlet size and location. Missing PCR stationing. Number: 154 Created: 1 /16/2006 [1/16/06] Brightwater — Where the street widens out - only 1 radius identified. What is the inside radius? Make it at least a 3 foot radii — no angle pts allowed. Number: 155 Created: 1 /16/2006 (1/16/06] Bowside —A driveway is shown to installed off of the north side of this roadway into the future community center, but it is shown entering into an area where a building is shown. Do you want this driveway installed? If you do, provide station and width information. If no remove from the plans. Number: 156 Created: 1 /16/2006 [1/16/06] Bowside —What is the centerline curve information? Number: 157 Created: 1 /16/2006 [1/.16/06] Bowside - Have a sump vertical curve where the grades will be less than .5%. This should not be designed as a vertical curve, but straight grades of .5% should be used to tie into the inlet. See 7.4.B.4.c. I have attached a detail in the detail section that identifies out that at sumps no less than a .5% grade should be provided — that will be used in conjunction with the other vertical curves. In this situation though because you are at minimum grades going into the curve no curve can be used. Number: 158 Created: 1 /16/2006 [1/16/06] Flagship Drive —Need to provide stations and widths for the driveways (south side only). Number: 159 Created: 1 /16/2006 [1/16/06] Seafarer —The tangent between curves is not being met— Please note this variance in the variance list on the cover sheet. Number: 160 Created: 1 /16/2006 [1/16/06] Clarion Lane - The end of Phase 1 line on the profile does not match the location of the phase line on the plan view. At the end of Phase 1, note and show that a temporary turnaround is to be provided with Phase 1. Page 3 4. Y Number: 60 Created: 6/3/2004 [1/16/06] [6/14/05] [1/31/051 This is being done with the first filing and the improvements will need to be complete before any building permit is issued with the 2nd filing. Just keeping this comment alive until the DA. [6/3/04] This project is responsible for the construction of County Road 52 along their frontage. Number: 127 Created: 6/23/2005 [1/16/06] [6/23/05] The oil company will need to sign off on all of the plan sets (site, landscape, utility, and plat). Topic: Grading Sheets Number: 79 Created: 1 /28/2005 [1/16/061 [6/14/05] [1/28/05] If reworking the detention pond from the first filing, we'll need temp construction and grading easements from the first filing OR you can revise the 1st filing utility sheets. Topic: Landscape Number: 56 Created: 5/25/2004 [1/16/06] [6/15/05] [1/31/05] This set does not meet the requirements of Appendix E6. [5/25/04] Please see Appendix E6 for scanning requirements. Department: Enginveering Issue Contact: Sheri Wamhoff Topic: Plan and Profiles Number: 146 Created: 1 /16/2006 [1/16/06] Susan verified she waived the 500 foot off -site design requirement for Thoreau. This variance needs to be noted on the cover sheet under variances granted? Number: 147 Created: 1 /16/2006 [1/16/06] Street Plan and Profile sheets — need to work on the scanability of these sheets. It would probably help some if you turned off the water and sewer layers as there would be fewer lines for the text to conflict with. Keep the storm lines on the plans as it shows where the inlets are and that system works. Need to make sure the station numbers and other text and information are readable and not overlapping. Number: 148 Created: 1 /16/2006 [1/16/06] By,choosing to provide centerline and flowline stationing rather than just using centerline stationing for the flowline profiles you need to provide x-sections of the streets in at least the following locations beginning, middle and end of any horizontal curve. Some x- sections were provided on separate sheets as exhibits. This information needs to be included in the plan set, so that a record of the design is maintained. Additional x-sections need to be provided for Thoreau — beginning, middle and end of horizontal curve. Number: 149 Created: 1 /16/2006 [1/16/06] On roadways where tying into roadwork that will be apart of the 1st filing show this area as existing (even if it is not at the moment — it should be by the time this work is done) and identify where the tie should occur (PC,PT, etc). Page 2 STAFF PROJECT REVIEW Gtv of Fart Collins VIGNETTE STUDIOS Date: 01/17/2006 TERENCE HOAGLUND 144 N. MASON ST. #2 FT. COLLINS, CO 80524 Staff has reviewed your submittal for LIND PROPERTY 2ND FILING PDP/FC - TYPE I, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Susan Joy Topic: Cross Sections Number: 92 Created: 1 /28/2005 [1/16/06] X-slope exhibit received. See separate comment. [6/14/05] 1 did not receive the cross slope exhibit redlines from the last round of review or the corrected exhibit to review. This issue remains open. Comments under the Plan and Profile section will change most of the cross sections previously submitted and will need to be reviewed as a new submittal. [1 /28/051 See redlines for the cross slope exhibit comments. Some areas outside the transition areas do not meet the minimum 2% cross slope requirement. Thank you for the exhibit, it really made reviewing the design easy!! Department: Engineering Issue Contact: Sheri Wamhoff Topic: Details Number: 163 Created: 1 /16/2006 [1 /16/06] Add the following details to the plans — Sump condition flowline detail (have attached an example). Trail detail. Department: Engineering Issue Contact: Susan Joy Topic: General Number: 44 Created: 4/23/2004 [1/16/06] Offsite easements need to be provided. Please note that as of January 1, 2006 there is now a processing fee for each easement needed and submitted for processing. For easement dedications this is $250 for each easement and for vacations this is $400 for each easement. The fees will apply to this project and the easements to be submitted since they will be submitted after the first of the year. Appears that the following off -site easements are needed: grading and construction easements, drainage easement, temporary turnaround easement, drainage, grading and utilty easement and maybe a utility easement. [6/14/05] Offsite grading and construction easements required from Filing One and Filing Three. Please provide legals and exhibits for verification and then you'll need to record them. The grading around the detention pond in Filing One can be handled as a revision to Filing One plans. Grading offsite to the east of Filing Two will require offsite grading and construction easements from that property owner. [1/27/05] Easements need to be recorded for any offsite improvements and the reception number needs to go on the plans. [5/25/04] [4/23/04] Please provide letters of intent from the ditch company and/or other property owners for offsite grading in order to go to hearing. The actual easement can be provided during final compliance. Page I