Loading...
HomeMy WebLinkAboutHORSETOOTH EAST BUSINESS PARK, DALE'S CARPET ONE - FDP - 43-94L - SUBMITTAL DOCUMENTS - ROUND 1 - STAFF'S PROJECT COMMENTSDepartment: Transportation Planning Issue Contact: Tom Reiff Topic: General Number: 52 Created: 4/27/2004 14/27/04] No further comments. Department: Water Wastewater Issue Contact: Jeff Hill Topic: General Number: 53 Created: 4/27/2004 [4/27/04] Maintain a 4-foot minimum separation between the future building envelope and the proposed meter pit. See site, landscape and utility plans for other comments. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Yours Truly, Bob Barkeen City Planner Page 2 STAFF PROJECT REVIEW Citvof Fort Collins W.J. FRICK DESIGN GROUP Date: 04/30/2004 C/O BUD FRICK 526 S. COLLEGE AVE. FT. COLLINS, CO 80524 Staff has reviewed your submittal for HORSETOOTH EAST BUSINESS PARK, DALE'S CARPET ONE PDP - FINAL PLAN, and we offer the following comments: ISSUES: Department: Current Planning Topic: Erosion Control Number: 50 [4/28/04] Issue Contact: Bob Barkeen Created: 3/2/2004 [3/2/04] Screening of the loading area. Evergreen Trees will need to be planted adjacent to the loading area (south of the trash enclosure) to provide screening from Automation Way. Number: 51 [4/28/04] Created: 3/2/2004 [3/2/04] There is a landscape gap along Automation Way. Additional trees should be incorporated in this area to fill in the gap. Department: Engineering Issue Contact: Katie Moore Topic: General Number: 56 Created: 4/28/2004 [4/28/04] The Site plan still shows a building or building envelope overlapping a utility easement. This is not allowed. Please revise your building envelope to remove it from any easements. Topic: Plat Number: 55 Created: 4/28/2004 [4/28/04] Please see redlines for changes to a note on the plat. Department: Light & Power Issue Contact: Doug Martine Topic: Light & Power Number: 6 Created: 12/9/2003 [3/31/04] The developer will need to coordinate power requirements, transformer location, and electric development charges with Light & Power Engineering (970)221-6700. Department: Police Topic: General Number: 57 [4/28/04] No revised photometrics - parking lot requires 1.Ofc. Department: Stormwater Utility Topic: Drainage Number: 54 Please see minor comments on the redlined plans. Issue Contact: Joseph Gerdom Created: 4/28/2004 Issue Contact: Wes Lamarque Created: 4/28/2004 Page 1