Loading...
HomeMy WebLinkAboutBRIDGEFIELD P.U.D. - PRELIMINARY - 45-94 - CORRESPONDENCE - (5)18. The bridge must meet HS20 loading requirements. Please contact Kerrie Ashbeck or Mike Herzig at 221-6750 if you need more details. 18. Street oversizing fees are $584.00 per dwelling unit and are collected at the time of building permit issuance. 19. A standard engineering submittal is required. The requirements are outlined in the Development Manual. 20. A neighborhood meeting is. -required. Please contact Steve Olt about scheduling this meeting. 21. A minimum of 65% of the lots must meet the definition of a solar oriented lot. Please refer to the Solar Orientation Ordinance. These lots must be designated on the plat and site plan and written information provided on the % of lots meeting the definition. 7. There is a parkland fee of $779.00 per dwelling unit collected at the time of building permit issuance. 8. Parks and Recreation is looking at an informal "path", unpaved along the ditch in this area. Stormwater is also working with Parks to provide some kind of public access to the area purchased by the City. This proposed development should provide adequate pedestrian connections within the development and to surrounding properties. 9. The property is located in the Canal Importation drainage basin. Stormwater development fees are $6181.00 per acre subject to the coefficient of run-off and provisions for on - site detention. 10. Submittal requirements include a standard stormwater drainage and grading plan, drainage report, and erosion control plan for the construction phase. These requirements are outlined in the Development Manual. 11. There is an existing drainage easement on this property at the south end for drainage purposes. Please contact the Stormwater Utility (Glen Schlueter) for more information about this easement. The portion of property located in the flood plain requires a special use permit and other restrictions apply, such as flood proofing, etc. Please verify the location of the flood plain in this area and show this line on the site plan and plat. 12. The Natural Resources Department has written .a memo regarding their concerns (see attached). 13. A traffic study is required as part of the submittal. The study should focus on traffic volumes expected to be -generated from this project, the single point of access onto Prospect Road, alignment of the proposed access point with the street on the north side of Prospect Road, and stacking of vehicles on Prospect Road and on the site. 14. A repay is due to the City for improvements made to Prospect Road. Please contact Matt Baker at the City's Engineering Department for more information. 16. You will need to meet current City street standards for all public streets, or variances must be requested at the time of submittal. Variances must be written and signed by a licensed engineer. 16. Would it be possible to provide access to the out parcel to the east, through this property? 17. Ditch company approval will be required for the ditch crossing. Ditch company's review the plat and utility plans and a sign -off signature block must be provided. .N CONCEPTUAL REVIEW STAFF COMMENTS MEETING DATE: July 11, 1994 SUBJECT: Single family at Prospect and Constitution .(south side of Prospect Road between Heatheridge and the Bridges. LAND USE: 95 single family detached "cottage homes" on 18 acres. COMMENTS: 1. There are Light and Power facilities on the south side of Prospect Road near this site. If you bridge the ditch you need to incorporate conduit for utilities in the bridge design and coordinate with the various utilities. 2. A utility coordination meeting will be required for this project given the configuration of drives and streets. Kerrie Ashbeck at the City Engineering Department (221-6750) will schedule the meeting at an appropriate time, before and/or after submittal. 3. The site is located within the RLP and RP zones. The product you are proposing would require a Planned Unit Development, PUD. 4. There is an 18"'sewer line in Prospect and it is fairly deep. There is also a 15" sewer line north of Heatheridge Lake. There is a 12" water line in Prospect Road and a 6" main in the apartment development to the east (Heatheridge) which you should tie into to provide a loop to maintain adequate pressure in the area. 5. Fire Authority will want to make sure that adequate .fire access is maintained, including 20' of clear access. Fire hydrants must be located within 400' of all structures. Please show the location of fire hydrants on the site plan. The standard 150' fire access around all buildings must be maintained or buildings must have fire sprinkler systems. 6. The second point of access will require negotiations with the property to the east. Those negotiations will be your responsibility. The emergency access drive and barriers must meet the Fire Authority's standards, 20' of all weather surface, etc. COMMUNITY PLANNING & ENVIRONMENTAL SERVICES 281 NORTH COLLEGE P.O.BOX 580 FORT COLLINS, COLORADO 80522-0580 (303)221.6750 PLANNING DEPARTMENT w c CommL y Planning and Environmental rvices 7 _ Planning Department City of Fort Collins July 21, 1994 John Prouty Lagunitas Co. 3307 S. College Ave. Fort Collins, Co 80525 Dear John: For -your information, attached is a copy of the Staff's comments concerning 95-single family detached -'cottage homes' or718 acres;ypre sented before the Conceptual Review Team"on July-11;-1994.-. The comments are offered informally by Staff to assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 221-6750. Sincerely,- ,g,l z/(-- ),�t Kirsten Whetstone, AICP Project Planner KAW/gjd Attachments cc: Bob Blanchard, Chief Planner Transportation Department Stormwater Department Project Planner File 281 North College Avenue • P.O. Box 580 • Fort Collins, CO B0522-0580 • (303) 221-6750