Loading...
HomeMy WebLinkAboutBRIDGEFIELD P.U.D. - PRELIMINARY - 45-94 - CORRESPONDENCE - STAFF'S PROJECT COMMENTS****************************************************************** Plan revisions are due no later than the end of the working day, October 5, 1994. Please contact me for the number of folded revisions required for each document. PMTIs, renderings, and 8 folded copies of final revisions (for the Planning and Zoning Board packets) are due by 3:00 p.m. on October 17, 1994. ****************************************************************** Please contact me at 221-6750 if you have questions or concerns related to these comments. I would like to schedule a meeting with you as soon as possible, if necessary, to discuss these comments. Sincerely, Asteot4— Project Planner xc: Ron Phillips, Planning Director Bob Blanchard, Chief Planner Kerrie Ashbeck Advance Planning Stormwater Utility Transportation Parks & Recreation Natural Resources file/Project Planner V g) There are two drafting errors in the boundary. Please contact Kerrie Ashbeck or Sheri Wamhoff, at 221-6750, if you have questions about these engineering comments. 13. The proposed five lots between the Larimer County Canal No. 2 and the New Mercer Ditch, to be accessed from West Stuart Street, cannot be developed. The City purchased an easement from Keith Sharf in January, 1992 for storm drainage purposes. There is a statement in this recorded easement to the effect that "Grantor shall not erect or.construct any building or other structure,". This document is recorded in the Larimer County Clerk & Recorder's Office under Reception #92004395. 14. A secondary emergency access is required for the 36 lot portion of the development south of the Larimer County Canal No. 2 and north of the Heatheridge pond. The Heatheridge development does not need this emergency access but the Bridgefield P.U.D. does. Verification of an access easement agreement with the Heatheridge development must be provided to the City no later than the revision due date of October 5, 1994. 15. The geometrics of primary access point (containing the center median) on West Prospect Road are awkward and should possibly be redesigned. 16. The setback distances of the drives paralleling West Prospect Road are not adequate. This is especially true in the northwest corner of the proposed development. 17. There are.significant drainage concerns associated with this development. No preliminary contours were submitted and it is very difficult to see how the grading will work. Information must be submitted to the City for review no later than the revision due date of October 5. 1994 or this item will be taken off of the agenda for the October 24th Planning and Zoning Board hearing and continued to a later date. 18. Access to some of the lots seems very awkward (#'s 23, on the top section, and 34, on the lower section, as examples). 19. There is a recently adopted City Ordinance No. 76, 1994 that deals with landscape design guidelines and irrigation design guidelines for developments. The common areas of this development are subject to the new ordinance, which is available in the Planning Office. This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please be aware of the following dates and deadlines to assure your ability to stay on schedule for the October 24,-1994 Planning and Zoning Board hearing: 11. The Natural Resource Division has the following comments to offer: a) The Division has been, and still is, interested in acquiring the lower portion of the property (south of the northerly portion of the Larimer County Canal No. 2 and north of the Heatheridge pond). b) If the Division fails to acquire the lowland piece they will still require a wetland delineation to be conducted for it as specified in their memo dated July 13, 1994. They will also require design considerations (i.e., native plant landscaping and buffer zones of 30' next to ditches and 100' next to wetlands) unless it can be shown that water quality will not be impacted by the development. c) Please indicate how public bicycle/pedestrian access may be provided to the open space around Heatheridge Lake. d) The south lots, 1 through 5, will not be permitted to be developed. Please contact Susie Gordon, at 221-6600, if you have questions about these natural areas comments. 12. The Engineering Department has the following comments to offer: a) A.secondary emergency access is required for the portion of the development south of the Larimer County Canal No. 2 and north of the Heatheridge pond. b) Definition is needed between the public and private streets. Currently, the public streets blend into the private. City Code requires City streets to end in a publicly dedicated turn -around. A meeting is suggested to discuss the options. c) The parking numbers appear to be adequate; however, the parallel parking areas shown on the plans are 6.33' wide. This is short of the 7' wide parking variance requested, S' is the standard and is being suggested. d) Add a north arrow, scale, and major identifying streets and sites to the Vicinity Map. e) Add approximate acres to the legal description. f) It is being suggested that the final survey be adjusted. The Preliminary Plat closes at 11: 2,9301. This is barely acceptable for urban standards. 4' 4. The "duplexes" appear to be one unit per lot. These are probably more correctly called "0-lot line attached single family" dwellings. Separate building permits are required for each lot. 5. The layout of the development could create addressing problems. 6. The Poudre Fire Authority has the following comments to offer: a) Fire hydrants must be located within 400' of all dwelling units and the hydrants must be capable of 1,000 gallons per minute with 20 pounds per square inch residual pressure. b) The bridge must be constructed to withstand the weight of fire department apparatus (H6). c) The streets shown as 34' in width must be a minimum of 36' wide. d) The proposed emergency access must be constructed of hard surface, all weather material. Please contact -Mike Pretz, at 221-6570, if you have questions about these comments. 7. The City Light & PowerDepartmenthas indicated that they will require a utility coordination meeting before they can make any meaningful comments. This project has many of the"same concerns, if not more, than the Indian Hills project. Clarification is needed on the utility routes. Please contact Bruce Vogel, at 221-6700, if you have questions about the electric service comments. 8. The Transportation Department has stated that the parking requirements and assumptions for this development need to be evaluated. Also, the street width issues need to be resolved. 9. The developer should schedule an on-site.meeting with Tim Buchanan, the City Forester, to evaluate the existing trees on -site. Also, the City Forester should be consulted about what species of trees to use as street trees along West. Prospect Road. 10. Public access is needed to the City -owned open space that is west of the project adjacent to the Bridges P.U.D. development. Access should be from West Stuart Street and West ,Prospect Road. Commw. _ f Planning and Environmental . vices - � Planning Department City of Fort Collins September 13, 1994 Jon Prouty Lagunitas Company 3307 South College Avenue, 4200 Fort Collins, CO. 80525 Dear Jon, Staff has reviewed your documents for the Bridgefield P.U.D. - Preliminary that were submitted to the City on August 22, 1994, and would like to offer the following comments: 1. Columbine CableVision TV has the following comments to offer: a) CCTV would like to see all utility easements marked on the plat map. They would also like to see the open space along West Prospect Road (west of the entry drive) marked as a utility easement. b) CCTV would like to work with the developer on installing their main lines in a joint trench with U.S. West telephone or City power. They would also like to see thee buildings pre -wired with cable and in accordance with a method that meets their standards. 2. Public Service Company of Colorado has the following comments to offer: a) PSC needs a 6" sleeve in each bridge for a gas main crossing. b) Easement widths adjacent to rights -of -way and drives need to be 13' from the back of sidewalks to the rear easement line. c) There is a strong possibility that West Prospect Road will have to be open cut to extend into this development. d) Tree planting within 4' of gas lines is prohibited. e) Private drives and open spaces should be designated as utility easements. , 3. The Post Office has no concerns as long as interior drives are not named. 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 8052-0580 • (303) 21-6750