HomeMy WebLinkAboutCHERRY STREET COTTAGES - PDP - PDP160041 - CORRESPONDENCE - STAFF'S PROJECT COMMENTS06/21/2017: Some of the right of way descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. Department: Water -Wastewater Engineering Contact: Wes Lamarque, 970-416-2418, wlamargue@fcgov.com Topic: General Comment Number: 1 Comment Originated: 12/29/2016 06/21/2017: Please add a note on the Utility Plan that the sewer service is to be abandoned at the main. 12/29/2016: The sewer service needs to be abandoned at the main. Comment Number: 2 Comment Originated: 12/29/2016 06/21/2017: Repeat Comment. 12/29/2016: Pease label the new water services as wet taps. Comment Number: 3 Comment Originated: 06/21/2017 06/21/2017: Please show and label all proposed and existing curb stops. Comment Number: 4 Comment Originated: 06/21/2017 06/21/2017: Please add the City's Fire Hydrant Assembly detail to the Detail Sheet. 11 Landscape Plan set, and a Utility Plan set. 12/28/2016: The Site & Landscape plans need to be separated from the Utility plans. Topic: Landscape Plans Comment Number: 9 Comment Originated: 12/28/2016 06/21/2017: There are line over text issues. See redlines. 12/28/2016: There are line over text issues. See redlines. Comment Number: 20 Comment Originated: 06/21/2017 06/21/2017: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Topic: Plat Comment Number: 1 Comment Originated: 12/28/2016 06/21/2017: This will be checked at the next round of review. 12/28/2016: The legal does not close. The boundary closes using the measured bearings. Comment Number: 2 Comment Originated: 12/28/2016 06/21/2017: Please make changes as marked. If changes are not made or you disagree with comments, please provide written response of why corrections were not made. Please provide any responses on redlined sheets and/or in response letter. 12/28/2016: Please make changes as marked. If changes are not made or you disagree with comments, please provide written response of why corrections were not made. Please provide any responses on redlined sheets and/or in response letter. Comment Number: 3 Comment Originated: 12/28/2016 06/21/2017: This has not been provided. 12/28/2016: Please provide current acceptable monument records for the aliquot corners shown. These should be emailed directly to Jeff at jcounty@fcgov.com Topic: Site Plan Comment Number: 6 Comment Originated: 12/28/2016 06/21/2017: This has not been completely corrected. See redlines. 12/28/2016: There are spelling issues. See redlines. Comment Number: 7 Comment Originated: 12/28/2016 06/21/2017: There are line over text issues. See redlines. 12/28/2016: There are line over text issues. See redlines. Comment Number: 8 Comment Originated: 12/28/2016 06/21/2017: Some of the easement descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. 12/28/2016: There are easements shown that are not referenced on the Subdivision Plat. Are these being dedicated by separate document? Comment Number: 18 Comment Originated: 06/21/2017 06/21/2017: The Subdivision Plat needs to be removed from the plan set. Comment Number: 19 10 Comment Originated: 06/21/2017 January 1, 2015, all projects are required to be on NAVD88 datum. Please provide the following information for the Benchmark Statement in the EXACT format shown below. PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - X.XX6. Comment Number: 15 Comment Originated: 12/28/2016 06/21/2017: There are line over text issues. See redlines. 12/28/2016: There are line over text issues. See redlines. Comment Number: 16 Comment Originated: 12/28/2016 06/21/2017: Some of the easement descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. 12/28/2016: There are easements shown that are not referenced on the Subdivision Plat. Are these being dedicated by separate document? Comment Number: 17 Comment Originated: 12/28/2016 12/28/2016: There are text over text issues. See redlines. Comment Number: 21 Comment Originated: 06/21/2017 06/21/2017: Comment Number: 22 Comment Originated: 06/21/2017 06/21/2017: Some of the right of way descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. Comment Number: 23 Comment Originated: 06/21/2017 06/21/2017: Some of the sheet titles in the sheet index do not match the sheet titles on the noted sheets. See redlines. Topic: General Comment Number: 4 Comment Originated: 12/28/2016 06/21/2017: These plan sets need to be completely separated. A Site & M grading around structures and in the tracts. The detention pond needs to be graded out showing the outlet structure. 12/27/2016: Please provide a detailed grading plan showing grading around the proposed structures. Comment Number: 25 Comment Originated: 12/27/2016 06/21/2017: Please see redlines for revisions to the outlet structure table. 12/27/2016: Please use and provide the detail for the City's standard water quality outlet structure. Comment Number: 29 Comment Originated: 06/21/2017 06/21/2017: The linework on the sheets in the Utility Plans are incomplete and do not show all of the improvements. Comment Number: 30 Comment Originated: 06/21/2017 06/21/2017: Please show existing off -site grading 50 feet from the property line to document all grading will tie into existing grades. Comment Number: 31 Comment Originated: 06/21/2017 06/21/2017: The inlet at the end of the alley needs sizing calculations and a sub -basin to document the flows entering the inlet. Comment Number: 32 Comment Originated: 06/21/2017 06/21/2017: Please provide an actual Drainage Easement for Tract A. Comment Number: 33 Comment Originated: 06/21/2017 06/21/2017: The detention pond needs to meet the City's Detention Pond Landscape Standards. This includes varying and inundating slopes with some plantings. Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Construction Drawings Comment Number: 13 Comment Originated: 12/28/2016 06/21/2017: Please provide the following information for the Benchmark Statement in the EXACT format shown below. PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - X.XX'. 12/28/2016: The City has moved to the NAVD88 vertical datum, and as of 9 any work in the floodplain. Comment Number: 9 Comment Originated: 12/21/2016 06/20/2017: This information was added to the drainage report, but was not included on D-1. 12/21/2016: On Sheet D-1 of the Utility Plans, please create a table showing the BFE at the upstream edge of each building, and the RFPE (BFE + 18�), the FF elevation, and the HVAC elevation for each building within the floodplain. Comment Number: 10 Comment Originated: 12/21/2016 06/20/2017: This information was not provided as requested. 12/21/2016: On Sheet D-1 of the Utility Plans, please include a detail drawing for each foundation type (slab -on -grade or crawl space) showing the BFE, RFPE, FF, and HVAC elevations. Comment Number: 11 Comment Originated: 12/21/2016 06/20/2017: Please include building outlines and FF of the garages and the houses. 12/21/2016:On Sheet D-1 of the Utility Plans, please add Finished Floor elevations for each building. Comment Number: 26 Comment Originated: 06/20/2017 O6/20/2017: On the Site Plan (S1), please add a note that basements are not allowed on Lots 3, 4, 5, or 6 due to the presence of the floodplain. Comment Number: 27 Comment Originated: 06/20/2017 06/20/2017: Please move the cross -sections from the Erosion Control Plan (E-1) to the Drainage Plan (D-1). Comment Number: 28 Comment Originated: 06/20/2017 06/20/2017: Please remove the BFE designation from the Erosion Control Plan (E-1). Contact: Wes Lamarque, 970-416-2418, wlamargue@fcgov.com Topic: General Comment Number: 22 Comment Originated: 12/27/2016 06/21/2017: The LID design is required to be volume based. The City suggests a meeting to further clarify this requirement. 12/27/2016: No LID per the City's requirements was proposed for this development. Comment Number: 23 Comment Originated: 12/27/2016 06/21/2017: The Drainage Plan is incomplete and does not clarify if any off -site flows are entering the site. 12/27/2016: Please provide a drainage plan with all basins shown, including off -site basins that drain through the site. Comment Number: 24 Comment Originated: 12/27/2016 06/21/2017: The Grading Plan is incomplete and does not show all of the ►7 Comment Number: 5 Comment Originated: 12/28/2016 06/21/2017: This dimension needs to labeled on the plan. 12/28/2016: The garages must beset back from the private alley by eight feet. Comment Number: 6 Comment Originated: 12/28/2016 06/21/2017: replace carriage unit with "second story dwelling unit" 12/28/2016: For Lots one, two and three, please label the garages indicating that they are also planned to include second story carriage units. Comment Number: 9 Comment Originated: 12/28/2016 06/21/2017: repeat comment 12/28/2016: On the Site Plan, all the line weights are the same. Please use heavier line weight to demarcate the individual lots. Comment Number: 11 Comment Originated: 12/28/2016 06/21/2017: repeat comment 12/28/2016: On the Site Plan, please label the retaining wall. On the Landscape Plan, please provide a schematic as to the height and materials of this wall. On the Site Plan, please label the adjoining use to the north. Comment Number: 13 Comment Originated: 12/28/2016 06/21/2017: Repeat comment 12/28/2016: On the Landscape Plan, the detention pond needs additional plant material. Please add trees and shrubs in areas that will not be impacted by inundation. Also, please label the ground cover. Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-29329 ischlam@fcgov.com Topic: Erosion Control Comment Number: 1 Comment Originated: 12/12/2016 12/12/2016: The site disturbs more than 10,000 sq. ft., therefore Erosion and Sediment Control Materials need to be submitted. The erosion control requirements are in the Stormwater Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3. Current Erosion Control Materials Submitted do not meet requirements. Please submit; an Erosion Control Plan (Based on Redlines), an Erosion Control Report (That meet City Criteria), and an Escrow / Security Calculation (Based upon Criteria). If you need clarification concerning the erosion control section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com Contact: Mark Taylor, 970-416-2494, mtaylor@fcgov.com Topic: Floodplain Comment Number: 3 Comment Originated: 12/21/2016 06/20/2017: This note didn't end up on the Utility Plans. On Sheets U-2, D-1, and G-1, please include a note that a floodplain use permit will be required prior to beginning any work in the floodplain. 12/21/2016: On Sheets U-1, G-1, and D-1 of the Utility Plans, please include a note indicating that a floodplain use permit will be required prior to beginning 06/21/2017: Remove proposed grading lines from the site plan. Comment Number: 17 Comment Originated: 06/21/2017 06/21/2017: We often have issues with the construction of stairs and any need handrails. If there are stairs to be constructed for each lot within the utility easement and through a retaining wall, separate from porch stairs, a typical section detail will be needed to provide consistency and ensure that the stairs are constructed properly in the easement area. Comment Number: 18 Comment Originated: 06/21/2017 06/21/2017: Clarify in the land use table the amount of off-street parking provided for each lot and where the off-street parking will be located. Comment Number: 19 Comment Originated: 06/21/2017 06/21/2017: Lighting — this will be done per city standards. Need to clarify whether the special street light will be permitted. Lighting locations need to be confirmed with City Light and Power if this has not yet been done. Comment Number: 20 Comment Originated: 06/21/2017 06/21/2017: Landscape plan needs work be round 1 comments. Also add standard planting details and a parkway sod detail. Comment Number: 21 Comment Originated: 06/26/2017 06/26/2017: Please see redlines from Planning, Technical Services and Utilities staff. Contact: Ted Shepard, 970-221-6343, tshepard@fcgov.com Topic: General Comment Number: 1 Comment Originated: 12/28/2016 06/21/2017: Please remove the utility plan index from the Planning Set cover page. 12/28/2016: Please re -arrange the Sheet Index. The Planning Set is to be separated from the Utility Plans. The Site Plan Notes sheet should become the Site Plan Cover Sheet. The Planning Set will then consist of the Site Plan Cover Sheet, Site Plan, and Landscape Plan. Please delete the City approval block in the lower right corner of these sheets as this block is for the Utility Plan only. loll send you an example of the proper City approval block. Comment Number: 3 Comment Originated: 12/28/2016 06/21/2017: Label on the site Plan "Tract A" and "Tract B" 12/28/2016: On the Plat and Site Plan, Lot 7 should be re -labeled as Tract One since it is not a buildable lot per se and will be owned in common. Under Plat Notes, please add a new note that states the purpose, ownership and maintenance of the Tract. Comment Number: 4 Comment Originated: 12/28/2016 06/21/2017: Still not clear on the site plan with the details requested below. 12/28/2016: Also, on the Plat and Site Plan, the private alley should be demarcated, dimensioned and labeled as Tract Two and removed from being included within the six individual lots. For example, its not clear where the private alley terminates to the east. Under Plat Notes, please add a new note that states the purpose, ownership and maintenance of the Tract. �i of 25 feet inside and 50 feet outside. > Be visible by painting and/or signage, and maintained unobstructed at all times. Sign locations or red curbing should be labeled and detailed on final plans. Comment Number: 3 Comment Originated: 12/28/2016 12/28/2016: PREMISE IDENTIFICATION: ADDRESS POSTING & WAYFINDING Addresses shall be posted on each dwelling unit and where otherwise needed to aid in wayfinding. A plan for accessing and locating the three additional dwelling units on the 3 west lots has not been clearly identified. An understanding of the plan is required before detailed comments can be provided. If access is by means of the private alley, monument signage will be required at the alley entrance. Code language below. > IFC 505.1: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible, visible from the street or road fronting the property, and posted with a minimum of six-inch numerals on a contrasting background. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Comment Number: 4 Comment Originated: 06/12/2017 06/12/2017: PRIOR PFA COMMENTS NOT ADDRESSED Poudre Fire Authority comments from 12/28/2016 were not addressed in the applicant's response letter dated 06/05/2017. Prior PFA comments shall remain outstanding until acknowledged and resolved by the applicant. In summary, the Site Plan should indicate man -doors on carriage house with walk approach so as to better understand accessibility. The three carriage units are required to be addressed separately from the main residences on Cherry St. A plan to resolve address posting and wayfinding to the units is required prior to approval. If carriage house access is to be from the private alley rather than a sidewalk from Cherry St (for example), a monument sign will be required at the alley entrance and the alley will need to function as a fire lane, meeting minimum access standards. Department: Planning Services Contact: Jason Holland, 970-224-6126, lholland@fcgov.com Topic: General Comment Number: 14 Comment Originated: 06/21/2017 06/21/2017: Linework on the plans is very difficult to read; elements cannot be distinguished and is not presentable to a hearing officer. Please refine the linetypes, line weights and line type scales used. Adjust line type scales in the lot detail so that the PL's/ROW and other lines used are more understandable. Comment Number: 15 Comment Originated: 06/21/2017 06/21/2017: Planning and Owner Signature blocks need to be added to the site plan cover sheet. Comment Number: 16 4 Comment Originated: 06/21/2017 Topic: General Comment Number: 4 Comment Originated: 12/27/2016 12/27/2016: Please contact Todd Vedder with Light & Power Engineering if you have any questions tvedder@fcgov.com or 224-6700. Please reference our Electric Service Standards to ensure electrical infrastucture installation is in compliance with City regulations. A link to this document is below. http://www.fcgov.com/utilities/business/builders-and-developers/development-fo rms-guidelines-regulations Comment Number: 5 Comment Originated: 12/28/2016 12/28/2016: Developer is responsible for any permitting needed for work done in floodways or floodplain areas. Comment Number: 6 Comment Originated: 06/21/2017 06/21/2017: Will carriage units be separately metered from single family detached units or will they be sharing the same meter? Comment Number: 7 Comment Originated: 06/21/2017 06/21/2017: Unit 6 does not have electric meter identified Comment Number: 8 Comment Originated: 06/21/2017 06/21/2017: Is electric primary service and transformer in utility easement? If not a easement will need to be dedicated for this line if it is crossing over lot lines Department: PFA Contact: Jim Lynxwiler, 970-416-2869, Ilynxwiler@poudre-fire.org Topic: General Comment Number: 1 Comment Originated: 12/28/2016 12/28/2016: FIRE ACCESS The Site Plan does not indicate how the three additional dwelling units on the western three lots will be oriented or accessed. Fire access is required to within 150' of all exterior portions of any structure. If primary access if via the private alley, the alley will need to serve as a fire lane, be dedicated as and Emergency Access Easement and be constructed to minimum fire lane standards (see next comment). Comment Number: 2 Comment Originated: 12/28/2016 12/28/2016: FIRE LANE SPECIFICATIONS A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: > Shall be designated on the plat as an Emergency Access Easement. > Maintain the required 20 foot minimum unobstructed width & 14 foot minimum overhead clearance. > Be designed as a flat, hard, all-weather driving surface capable of supporting 40 tons. > Dead-end fire access roads in excess of 150 feet in length shall be provided with an approved area for turning around fire apparatus. > The required turning radii of a fire apparatus access road shall be a minimum 3 Comment Number: 1 Comment Originated: 12/14/2016 12/14/2016: The TDRFees will be reviewed again with the next submittal as I am thinking that things will change. For example the site plan indicates that there will be a dwelling unit in the detention pond - which is unlikely. Any adjustments needed will be made at that time. Department: Environmental Planning Contact: Stephanie Blochowiak, 970-416-4290, sblochowiak@fcgov.com Topic: General Comment Number: 6 Comment Originated: 06/20/2017 06/20/2017: Besides lighting all other Environmental Planning comments addressed since December 2016 round of review. Thank you. Environmental Planning is ready for Hearing. Topic: Lighting Plan Comment Number: 5 Comment Originated: 06/20/2017 06/20/2017: Did not see a Lighting Plan. Will there be street lights? If so, need to see luminaire schedule and lighting plan by Final Plan stage of review. Department: Forestry Contact: Molly Roche, mroche@fcgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 01/03/2017 06/21 /2017: Continued: 01/03/2017: In the Landscape Planting Schedule, please list all trees as B&B (balled and burlapped). Comment Number: 2 Comment Originated: 01/03/2017 06/21 /2017: Continued: 01/03/2017: Please include Landscape Notes and Street Tree Notes, which are available through the City Forester. Comment Number: 3 Comment Originated: 01/03/2017 06/21 /2017: Continued: 01/03/2017: Are there any water or sewer service lines that cross the parkway? If so, please provide at least 66 separation from trees. Department: Light And Power Contact: Todd Vedder, 970-224-6152, tvedder@fcgov.com 2 Fort Collins Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov. com/developmen treview June 26, 2017 Paul C Sorensen SORENSEN ENGINEERING & CONSTRUCTION 1901 BEAR CT Fort Collins, CO 80525 RE: Cherry Street Cottages, PDP160041, Round Number 2 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Jason Holland, at 970-224-6126orjholland@fcgov.com. Comment Summary: Department: Engineering Development Review Contact: Katie Andrews, 970-221-6501, kandrews@fcgov.com Topic: General Comment Number: 10 Comment Originated: 12/19/2016 06/20/2017: See redlines for additional comments. Please return redlines with next round submittal. 12/19/2016: See redlines for additional comments. Please return redlines with next round submittal. Comment Number: 11 Comment Originated: 06/20/2017 06/20/2017: 11 foot ROW dedication is based on 7 foot parkway plus 4 foot sidewalk - the minimum required sidewalk width is 4.5 feet. Please label sidewalk width on utility and site plan. Comment Number: 12 Comment Originated: 06/20/2017 06/20/2017: A sidewalk chase drain is shown on the site plans but not on the utility plans. Please include the chase and more information about the ROW drainage in the utility plans. Comment Number: 13 Comment Originated: 06/20/2017 06/20/2017: A note on the plat indicates that the street ROW will be permanently maintained by the HOA... is this truly the intent? Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcqov.com Topic: General