Loading...
HomeMy WebLinkAboutBRIDGEFIELD P.U.D. - PRELIMINARY - 45-94 - SUBMITTAL DOCUMENTS - ROUND 1 - VARIANCE REQUEST2. A variance of the width of Access Street ROW from 54 feet to 34 feet and the flow line to flow line width from 36 feet to 29 feet, Table 1, Page T-1. The A.D.T. for each street where this section is proposed is 600. The street would have parking on one side only, and no parking signs will be provided by the developer. The parking would be reduced from 8 feet to 7 feet, the sidewalks would be 4 feet wide, and the driving lanes would remain 10 feet wide. The 7 foot wide parking area will be delineated by being concrete, with the two 10 foot. wide driving lanes being asphalt. There should not be problems in handling the traffic since the driving lanes remain 10 feet wide. The standard cannot be met with the garages in the rear of the lot which is desirable in order to not have the streetscape be all garage doors but rather permit the attractive house frontages and public - private, landscape - right-of-way areas as we have designed. We request that this variance be granted by reason of conditions peculiar to the site, namely the existing constraints including a) a single access from West Prospect Road at the north, b) an outlot (adjacent single family residence) at the northeast corner which must be respected, and c) a ditch (Larimer Canal #2) which bisects the property east - west creating an approximate eight -sided parcel north of the ditch and an approximate triangular shape parcel at the south of the ditch. Because of the existing constraints, there is no other way to lay out a project of this nature except in a looped right-of-way configuration with houses accessed off loop in a fashion similar to what we have shown. Furthermore, this plan is equal or better than a plan without this variance would be because this permits this innovative plan of smaller single-family houses however with character, quality, down -scaled right-of-way feel and excellent public -private, landscape - streetscape frontage. 3. A variance of Access Streets whereby egress loops will be permitted by means of connection to private driveway lane provided a) a public easement shall be granted for such use, b) all maintenance of private driveway lane shall be responsibility of Bridgefield HOA, and c) visual differentiation in paving shall be provided at connection point between the Public Street and the private drive. The justification for this is the low amount of traffic which will occur and will require turn -around for this street. This variance is required by the preexisting constraints of the project as described above. Granting this variance will not adversely affect the public health, safety or welfare and in fact will result in a project that is equal or better than it otherwise would be. If you have any questions regarding the variance requests, please call. Sincerely, 62� Richard A. Rutherford, P.EA L.S. President STEWART&ASSOCIATES Consulting Engineers and Surveyors August 22, 1994 Mr. Mike Herzig City of Fort Collins P.O. Box 580 Fort Collins, CO 80522 Dear Mike: This is a request for variances for residential streets in the proposed Bridgefield project located south of West Prospect Road and South Bryan Avenue. The variances are as follows: 1. A variance of the width of a Local Street ROW from 54 feet to 43 feet,Table 1, Page T-1. The parking would be reduced from 8 feet to 7 feet, the sidewalks would be 4 feet wide, and the driving lanes would remain 10 feet wide. The 7 foot wide parking area will be delineated by being concrete, with the two 10 foot wide driving lanes being asphalt. There should not be problems in handling the traffic since the driving lanes remain 10 feet wide. The standard cannot be met with the garages in the rear of the lot which is desirable in order to not have the streetscape be all garage doors but rather permit the attractive house frontages and public - private, landscape - right-of-way areas as we have designed. We request that this variance be granted by reason of conditions peculiar to the site, namely the existing constraints including a) a single access from West Prospect Road at the north, b) an outlot (adjacent single family residence) at the northeast corner which must be respected, and c) a ditch (Larimer Canal #2) which bisects the property east - west creating an approximate eight -sided parcel north of the ditch and an approximate triangular shape parcel at the south of the ditch. Because of the existing constraints, there is no other way to lay out a project of this nature except in a looped right-of-way configuration with houses accessed off loop in a fashion similar to what we have, shown. Furthermore, this plan is equal or better than a plan without this variance would be because this permits this innovative plan of smaller single-family houses however with character, quality, down -scaled right-of- way feel and excellent public - private, landscape - streetscape frontage. James H. Stewart and Associates, Inc. 103 S. Meldrum Street P.O. Box 429 Ft. Collins, CO 60522 303/482-9331 Fax 303/482-9382