Loading...
HomeMy WebLinkAboutNEW BELGIUM BREWERY - OVERALL DEVELOPMENT PLAN - 1-95C - CORRESPONDENCE -v'l along each development boundary that abuts potentially developable or redevelopable land. It is possible that street connections will be desired through your site to the north. c. Pay particular attention to section 3.2.1 of the LUC for landscaping standards, section 3.2.2 for parking standards, section 3.4.1 for Natural Habitats and Features standards, and section 3.5.1 for applicable building standards. d. Be sure to read sections 4.23(D)(1) Dimensional Standards, 4.23(E)(2) Building Design, and 4.23(E)(3) Site Design for standards specific to development within the I -Industrial zone. 5 (cardboard, cans, plastics, etc.), and dumpsters must be enclosed within a fenced or walled area. d. We ask that a single trash hauler be used to minimize traffic impacts. e. Native grasses and plant materials should be used wherever appropriate, and bluegrasses should be minimized. f. If construction lasts for more than 6 months, you will have to file a permit for fugitive dust control with Lorimer County. 6. Fire Department: a. The chemical storage for the treatment plant - involve PFA in the planning. b. The building must be sprinklered. c. Fire hydrants - capacity of 1500 g.p.m G 20 p.s.i. Hydrants must be spaced no further apart than 600 feet on center. 7. Light and Power: a. Single phase power is available on Laporte Avenue. b. You may need an easement to get the power from Laporte Avenue onto your site. c. If you build a commercial component to this development, 3 phase power would not be practical. d. Normal development fees apply. 8. Transportation: a. The TI5 update will need to address all modes of transportation including vehicle, bicycle, pedestrian and transit. Contact Eric Bracke (vehicular), Mark Jackson (ped & bike), and Gayleene Rossiter (transit) for scoping. b. Be sure that your internal pedestrian and bicycle circulation provides direct connections to nearby destinations. c. Bicycle parking must be provided near building entrances. d. Option 2 may have neighborhood opposition to the south. Keep that in mind. e. Buckingham is a collector. f. The proposed rail spur may conflict with the Fort Collins Streets Facility and the CDOT Facility north of this site. 9. Current Planning: a. Refer to Section 3 (General Development Standards), and Section 4.23 (Industrial Zoning District) in the Land Use Code for the standards that apply to your proposed development. The Land Use Code is available to view on the internet at www.ci.fort-collins.co.us/CITY HALL/CODES. b. As per Section 3.6.3(F) of the LUC, your development plan shall provide for future public street connections to adjacent developable parcels by providing a local street connection spaced at intervals not to exceed 660' 4 3. Engineering Department: a. The project will require a Traffic Impact Study (TIS) that addresses site access, and all modes of transportation including automobile, bicycle, pedestrian, and transit. b. Street Oversizing Fees are based on the Traffic Impacts. Check with Matt Baker for the specific amount of this fee for your project. c. The property will need to be platted where the proposed water treatment plant will be located. The dedication of right-of-way to standards includes necessary easements. d. The irrigation ditch on Buckingham will need to be relocated. e. Improvements will be needed to. the frontage along the area being platted (dedicate ROW and easements, move ditch out of ROW). f. Need to see any changes to existing drives. g. Need to see how proposed drives align with existing streets. h. Railroad spur - include info on use. Need to see how you plan on getting tracks to the site, how it affects other properties. Need easements and right-of-way. i. Lemay - if the project gets out this far, you would probably only need to escrow for improvements at this time. j. Need to plat. k. You will be required to have a Development Agreement, a Development Construction Permit, and Utility Plans. 4. Water & Wastewater Utility: a. An 8" sewer main was extended across the site of the building expansion. If this sewer runs under a area with only overhead conveyers, we may be able to make it work. b. There is and existing 12" water main, and an 8" sewer main in Buckingham. We are experiencing capacity problems in this area. c. Water Plant Investment Fees and Water Rights are due at the time of building permit. d. Water conservation standards for landscape irrigation will apply. 5. Natural Resources: a. An Ecological Characterization Study is required because there is a Riparian Forest identified on the city's for Natural Habitats and Features plan just south of this site. b. If there are any prairie dogs on site, they will have to be relocated or humainly eradicated. c. Trash enclosures should accommodate recycling containers of sufficient size to accommodate the type of recycling appropriate for the building use 3 Light and Power Transportation Services (ped. & transit) Transportation Services (traffic) Tronsfort (local bus service) Park Planning COMMENTS: Doug Martine 221-6700 Mark Jackson 416-2029 Eric Bracke 224-6062 Gaylene Rossiter 224-6195 Craig Foremean 221-6618 1. Zoning Department: a. The property is located in the I -Industrial zoning district. b. The use would be considered light industrial and office which are both Type 1 uses. c. An ODP would be Type 2 review. d. Ensure that there is adequate bicycle parking close to the door. It appears that you may need an additional rack. e. Provide trash enclosures. f. Provide the required number of handicap parking spaces. g. The landscaping looks good, but keep the residential buffer in mind. h. Industrial uses limit parking spaces to no more than 0.75 spaces per employee. i. No more than 15 parking spaces are allowed in a row without an intervening landscape island. All landscape islands within parking lots must have a tree and be at least 8 feet in their smallest dimension. 2. Stormwater Utility Department: a. This site is in the Dry Creek drainage basin where the new development fee is $5,000/acre which is subject to the runoff coefficient reduction. The brew house addition may be in the Poudre River basin where there are currently no new development fees. b. The site is in inventory grid #96. c. The standard drainage and erosion control reports and construction plans are required and they must be prepared by a professional engineer registered in Colorado. d. The existing outfalls for the site are limited so onsite detention is required. The standard release rate is the 2 year historic rate. However, the outfalls may even limit it more. I would suggest a meeting with Stormwater staff once the design engineer has reviewed the site constraints and has preliminary ideas of how to drain the site as well as the historic drainage patterns. A new outfall system to the Poudre River may be needed since there are properties in the County that are flooded frequently now. e. Water quality extended detention is required to treat runoff. f. This site is not in a floodplain or the Poudre River "product corridor". 2 MEETING DATE: August 7, 2000 ITEM: Expansion of New Belgium Brewery. APPLICANT: Angie Melewski BHA Design 4803 Innovation Drive Fort Collins, CO 80525 LAND USE DATA: The New Belgium owners actually own (or have an option on) all the property between the existing brewery building and Lemay. The applicant intends to submit an application for an ODP by early September. The expansion is proposed in 2 to 3 phases. This conceptual includes 2 future phases: (1) an addition to expand storage and distribution to the east of the existing building, and (2) an addition to expand the brew house to the north west between the existing building and Linden Street. The applicant is proposing an on site water treatment plant to reuse some of the water. A visitor center and possible bed & breakfast building are proposed in a new detached building near the south property line. The applicant is exploring the possibility of extending a rail spur from the railroad along drive to the site. Two alternatives were presented: option 1 had a new parking lot on the north side of the building, option 2 had an expanded parking lot on the south side of the building and a new service drive on the north. DEPARTMENTAL CONTACTS: Current Planning- Troy Jones 221-6750 Zoning Department- Jenny Nuckols 221-6760 Engineering Department- Sheri Womhoff 221-6605 Street Oversizing Coordinator- Matt Baker 221-6605 Poudre Fire Authority- Ron Gonzales 221-6570 Stormwater Utility- Glen Schlueter 224-6065 Water & Sewer Utilities- Roger Buffington 221-6854 Natural Resources Development Planner Kim Kreimeyer 221-6750 COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. PO. Box 580 Fort Collins, CO80522-0580 (970) 221-6750 CURRENT PLANNING DEPARTMENT i._ City of Fort Collins Commi y Planning and Environmental Current Planning Angie Melewski BHA Design 4803 Innovation Drive Fort Collins, CO 80525 Dear Ms. Melewski: vices August 25, 2000 For your information, attached is a copy of the Staff's comments concerning the New Belgium Brewery expansion presented before the Conceptual Review Team on August 14, 2000. The comments are offered informally by Staff to assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 221-6750. SiAcerely, Tro;/. Jon s City Planner cc: Eric Bracke, Streets Department 5tormwater Department Project Planner File 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020