HomeMy WebLinkAboutEVERGREEN PARK, LOT 6, BLK. 4 (AMERICAN MOBILE WELDING) - IL SITE PLAN REVIEW - 52-94 - CORRESPONDENCE - STAFF'S PROJECT COMMENTS17. Please add the following notes to the landscape plan: "A free (no charge) permit from the City Forester is required before any trees are planted, pruned, or removed from the public right-of-way." "The landscaping shall be irrigated. The irrigation plan must meet the irrigation standards of the City Water Department prior to issuance of building permit. Both landscaping and irrigation system must be installed according to approved plans, or an acceptable bond deposited with the City, prior,to issuance of a certificate of occupancy." "Mulches shall be used in the planting beds and shall be applied to a minimum depth of three inches." "All landscape materials shall meet spcifications of the American Association of Nurserymen (A.N.N.) for Number One Grade. A11 trees shall be balled and burlapped or equivalent." This concludes Staff comments at this time. Please feel free to call or visit our office to discuss these comments. Sincerely: Ted Shepard Senior Planner TS/gjd landscape requirements for the entire parcel would have to be installed. 7. The landscape plan should be revised. The street trees should not be an Elm. Please select one of the. following: Hackberry, Honey Locust, Green. Ash, Burr Oak, Littleleaf Linden, or Kentucky Coffee. 8. Also, Russian Olives are not allowed to be planted because they are non-native, aggressive, and tend to overtake native species. As an ornamental, please select Spring Snow Crab, Radiant Crab, or any other of the "Malus" Crab species. 9. Junipers should be used along the western foundation of the 'building. Please select the type of Juniper. Staff recommends Tam, Old Gold, Seagreen, or Buffalo. 10. The areas to be covered in turf grass should be specified. 11. The landscape table should indicate the quantity of plant material and the size. For sizes, please note: street trees should be two inches in caliper; ornamentals - 1 1/2 inches; shrubs.- five gallon. 12. The site shall be accessible to persons with disabilities in accordance with Uniform Building Code Section 3103 and U.B.C. Appendix Section 3106. For further information, please contact Sharon Getz, Building Inspection Plans Examiner, 221- 6760. 13. Please add the following note to the Plan: "The Transmission line easement is a restricted area, and access within the easement area must not be impeded. The following are prohibited on the United States Easement without the expressed written permission of the Western Area Power Administration, Loveland, Co.: structures, fences, drilling wells, changes in topography, and permission to the public for any use." 14. The Public Service Company requires the following note on the Plan: "No trees to be planted within four feet of gas line." 15. If there is to be an electrical transformer located on the site, then it needs to be screened. Screening may be by solid enclosure or plant material. Please contact Doug Martine, Light and Power Department, 221-6700 for further explanation on electrical requirements and fees. 16. U.S. West requires that you contact Tim Weaver, 221-7516, three months before construction for conduit requirements for telephone service. CommL_1ty Planning and Environmental . ervices Planning Department City of Fort Collins October 26,•1994 Mr. Dennis Smilie 2917 Loch Lomond LaPorte, CO 80535 Dear Mr. Smilie: Staff has reviewed the request for Storage/Office Building - I-L Site Plan Review on Lot 6, Block 4, Evergreen Park. The following comments are offered: 1. A Drainage Report, Grading and Drainage Plan, and Erosion Control Plan must be submitted to the City of Fort Collins Stormwater Utility. The administrative hearing for the I-L Site Plan Review cannot be scheduled until Stormwater Utility has had a chance to review and comment on how the site will handle stormwater runoff. Please contact Glen Schlueter, Stormwater Engineer, 221-6589, for further information on required materials. 2. The parking spaces are only ten feet in length. These must be 19 feet in length. Stalls that are 19 feet in length need 20 feet of back-up space in the drive aisle which is not available due .to proximity of the south property line. Consequently, the parking stalls must be shifted north to account for this additional back -up space. 3. Are two spaces sufficient? The Zoning Code requires a minimum of two spaces for every three employees. Will there be.only a maximum of three employees? It is recommended that additional parking be provided to account for customers, etc. 4. A five foot landscape strip is required along the south property line from the back of sidewalk to the phase line. This strip should feature a mix of evergreen and deciduous shrubs. 5. With the increase in parking stall length to 19 feet, and the five foot landscape strip on the south property line, the building should be shifted to the north. Otherwise, there is insufficient drive aisle width for the parking stalls and the overhead door. 6. The phase line must be fenced. If the area described as Phase Two is .used for storage or -any other purpose, then the 281 North College Avenue - P.O. Box 580 - Fort Collins, CO 80522-0580 - (303) 221-6750