HomeMy WebLinkAboutWATERFIELD PUD, FIRST FILING - FINAL - 7-95C - CORRESPONDENCE - STAFF'S PROJECT COMMENTSI. The 8-plex building that backs up to Merganser needs to be modified/shifted as it is too close to the r.o.w. Landscaping (potentially a screen wall) is needed to provide privacy for the residents. M. Additional trees are needed between the fronts of all multifamily buildings and the sidewalk/parking. Please refer to Preliminary PUD comments regarding this. Also refer to Advance Planning comments. n. Foundation plantings (trees and shrubs) are needed on the sides and rear of all multi -family buildings. Please also refer to Advance Planning comments. o. Please provide a fence detail an elevation sheet for the properties (out parcels) that are adjacent to the multifamily portion of the development. These fences must be shown and labeled on the Site and Landscape Plans. This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. As previously discussed, plan revisions for the Waterfield PUD, First Filing are due no later than July 29, 1997 in order to stay on schedule for the September 18, 1997 Planning and Zoning Board hearing. Please contact me for the number of folded revisions required for each document prior to the submittal of plan revisions. Please contact me at 221-6206 if you have any questions or concerns related to these comments. I would like to schedule a meeting with you as soon as possible, if necessary, to discuss these comments. Sincerely, %W'-4A . Michael Ludwig, AICP Project Planner xc: Tim Blandford Stormwater Utility file/Project Planner 13. Redlined Utility Plans from the ELCO Water District are attached. Please return redlined plans with plan revisions to Mike Ludwig of the Current Planning Department. 14. Redlined Utility Plans from the Water and Wastewater Utility are attached. Please return redlined plans with plan revisions to Mike Ludwig of the Current Planning Department. 15. The Current Planning Department offers the following comments: a. Please provide Final PUD building elevations for all multi -family building types and the clubhouse building. Building materials and colors must be labeled and specific (paint stock number, etc.). b. Please renumber all plan sheets accordingly to accommodate the inclusion of building elevations in the plan set. C. The zoning districts on the Site Plan vicinity map no longer exist. Please revise according the CityPlan zoning map. d. Please note the existing zoning in the Land Use Breakdown information. e. Please verify all gross and net area calculations after plan revisions are made. f. Please add overall density information for the First Filing in the Land Use Breakdown table (219 units on 27.5 acres =7.96 dwelling units per acre). g. Please add a note under the solar orientation data regarding the fact that a variance to All Development Criteria A-1.1 was granted at Preliminary on May 19, 1997. h. Please add a note that 16, 4-BR units are allowed per the P&Z during Preliminary on May 19, 1997. i. Please provide per unit type and overall parking calculations. The Bull Run portion of the development is short at, least 13 spaces. This is further impacted by the loss of 4 spaces where the potential access to the Plummer school site is shown (replace with landscape island). Please add at least 17 spaces to the plan (example: private drives are 30 feet wide and would allow on -street parking on one side). Please label the width of all sidewalks on the Site Plan. k. Please label the width of all drive aisles and parking stall dimensions. 9. Comments from the Advance Planning Department are attached. Please return redlined plans with plan revisions to Mike Ludwig of the Current Planning Department. 10. The Building Inspections Department offers the following comments: a. Apartments accessible and adaptable for use by persons with disabilities must be provided in accordance with Uniform Building Code Section 3103(a)8. As amended by the City of Fort Collins. The 1992 edition of the American National Standard Institute publications #A117.1 "Accessible and Usable Buildings and Facilities" should be used in the design of accessible/ adaptable dwelling units. A local amendment to the UBC requires that accessible units with numbers of bedrooms and other amenities be provided in numbers proportionate to the remainder of the project. When more stringent, the Colorado revised Statute, Title 9, Article 5, Section 111 also applies to apartment projects. Though not administered at the municipal level, similar requirements are contained in State and Federal civil rights legislation (Fair Housing Acts). Where provided in a project containing accessible dwellings, a portion of garages or covered parking must be accessible. b. 'The site shall be accessible to persons with disabilities in accordance with Uniform Building Code Section 3103 and UBC Appendix Section 3106. Provide a designated and marked "accessible route of travel' among all the buildings on the site and building exits and entrances and the public way (public sidewalk). Accessible routes shall comply with ANSI A117.1-1992 with running slopes no greater than 1:20 and cross slopes no steeper than 1:50. Where routes cross lanes for vehicle traffic, they shall be designated and marked as a cross walk. Provide parking and signs per Appendix Section 3107. Parking and access aisles shall comply with ANSI A117.1- 1992 with slopes no greater than 1:50 in any direction. C. Buildings shall be designed to comply with the Fort Collins Nonresidential Energy Code (ASHRAE 90.1 with local amendments) or Residential Energy Code (1995 Model Energy Code with amendments), whichever applies to each building. 11. Comments and redlined plans from the Engineering Department are attached. Please return redlined plans with plan revisions to Mike Ludwig of the Current Planning Department. 12. Comments and redlined plans/report from the Stormwater Utility are attached. Please return redlined plans/report with plan revisions to Mike Ludwig of the Current Planning Department. d. "Paired" water service locations must be coordinated with Light and Power prior to construction of the water lines. If water services conflict with planned electric vaults or streetlights, the water service locations will need to change. 4. The Zoning Department offers the following comments: a. Please make sure topo lines are removed from the final site plans Jmake Lqh&)• b. Please provide parking breakdown calculations for the Bull Run Apartments including the number of units, vehicle parking ratio, and number of spaces for each unit type. C. If dotted lines on the Site Plan represent building envelopes, then indicate as such. d. Please clarify (note on the Site Plan and Plat) who will maintain trees in the right-of-way. e. Please indicate distances from the building envelopes to the property lines. The distances shown from multifamily building envelopes along the north side of the Bull Run project are. not to the property line. They show a distance, but to what? 5. The Parks Planning Department stated that Neighborhood and Community Parkland Fees will be assessed on each dwelling unit based on the square footage of the unit. 6. The Poudre Fire Authority offers the following comments: a. An additional fire hydrant is required near the 8-plex located east of the Oppie property and at the northeast corner. b. Please check street names with Ken Jackson at Fire Dispatch. 7. Comments from Sommermeyer Wick & Campbell, LLC (attorneys for the Larimer and Weld Irrigation Company) are attached. 8. Public Service Company offers the following comments: a. Easements through Tract D are inadequate for natural gas. All areas outside of building envelopes should be designated as utility easements. b. No trees are to be planted within 4' of gas lines. Community Planning and Environmental Services Current Planning City of Fort Collins July 16, 1997 Country Club Farm, LLC c/o Cathy Mathis V-F Ripley Associates 1113 Stoney Hill Drive P.O. Box 271217 Fort Collins, CO 80525 Dear Cathy, Staff has reviewed your documents for the Waterfield PUD, First Filing, Final that were submitted on June 23, 1997, and would like to offer the following comments: 1. The Streets Department requests that a note be added to the Plat and Site Plan that clarifies the entity that is responsible for sidewalk snow removal on residential streets. 2. The Water Conservation Specialist states that the landscape plan shall include the total area (in square feet) for each landscape category. Landscape categories are distinguished by their water requirements and intended maintenance level. Examples of possible categories include, but are not limited to, high water turfgrass, low water turfgrass, low water planting beds, moderate water planting beds, and non -plant areas (paved areas, etc.). 3. The Light and Power Utility offers the following comments: a. Building envelopes in the apartment area are so close to the sidewalk, installation of both Public Service Company Gas and Light and Power electric may be difficult. Light and Power can install under the parking area, but historically, PSCo doesn't install their mains under asphalt. Please contact PSCo if they haven't already been contacted. b. Street tree locations need to be flexible so minimum clearances to streetlights can be maintained (40' from shade trees and 20' from ornamental trees). C. The lot numbers on V-F Ripley Associates drawings are quite different from those on Landstar Surveying Inc. drawings. Please coordinate. 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020