Loading...
HomeMy WebLinkAboutWATERFIELD PUD - PRELIMINARY - 7-95B - SUBMITTAL DOCUMENTS - ROUND 2 - STORMWATER-RELATED DOCUMENTSi 1 1 1 1 1 i 1 1 1 1 1 1 1 i 1 1 1 - 4985.000 4980.000 Larimer and Weld Canal , -i Looking East 4975.000 4970.000 4965.000 o ?' Piezometer B4 m Existing Ground Surface d 4960.000 � Piezometer Bi w 4955.000 SLC ? Ground Water Table 4950.000 SS _________ -- •- V 7 _______________ ............ SLC 4945.000 _? —_— — — _ _ -----______ _ SS . SG __ 4940.000 _. 0.000 200.000 400.000 600.000 800.000 1000.000 1200.006-:t 1400.000 1600.000 Distance (ft) Legend Riverside Technology, inc. SLC - Sandy Lean Clay SS - Silty Sand Figure 6 Notes: SG - Sand and Gravel 1. Boring lithology from Earth Engineering Consultants (Sept.1996). p E 2. Ground water table information is interpreted based on preliminary and limited information. •-------- Interpreted Ground Water Table Interpreted Cross Section 4 4985.000 4980.000 HOYA POR 4970.000 4965.000 c 0 eo 4960.000 w 4955.000 4950.000 4945.000 4940.000 0.000 Larimer and Weld Canal : . , Looking East ? ? Piezometer E35 Existing Ground Surface Ground Water Table ? SLC 200.000 400.000 Notes: 1. Boring lithology from Earth Engineering Consultants (Sept. 1996). 2. Ground water table information is interpreted based on preliminary and limited information. 800.000 1000.000 1200.000 Distance (ft) Legend SLC - Sandy Lean Clay SG - Sand and Gravel — 7 Interpreted Ground Water Table 1400.000 1600.000 1800.000 Riverside Technology, inc. Figure 5 Interpreted Cross Section 3 I 1 L7 F- L [1 1 IL 1 [1 4985.000 4980.000 4975.000 Looking East 4970.000 4965.000 ? ? Piezometer B6 c 4960.000 dGround Water Table Piezometer B9 w 4955.000 Existing Ground Surface SLC , ? Wetland Area 4950.000 SCS — — —•�._ _ _ _ SLC _ ►. T. 4945.000 SG------------------------------------------SCS SG 4940.000 4935.000 0.000 250.000 500.000 750.000 1000.000 1250.000 1500.000 1750.000 2000.000 2250.000 2500.000 2750.000 Distance (ft) Legend 6,794Riverside Technology, inc. SLC - Sandy Lean Clay SCS- Sandy Clayey Silt Notes: SG - Sand and Gravel Figure 4 1. Boring lithology from Earth Engineering Consultants (Sept. 1996). r 2. Ground water table information is Interpreted based on preliminary and limited information. 7 --- Interpreted Ground Water Table Interpreted Cross Section 2 G••1 4980.000 4970.000 c 4960.000 m w 4950.000 4940.000 4930.000 0. Larimer and Weld Canal Looking East Piezometer B7 SLC Piezometer BS Existing Ground Surface _tS_ _ _ ? SLC — . V�Ground Water Table SG Inn nrn nnn -- • - -•��� .,vv.vvv /DV.UVV IUUU.UUU Notes: 1. Boring lithology from Earth Engineering Consultants (Sept. 1996). 2. Ground water table information is interpreted based on preliminary and limited information. 1250.000 Distance (ft) Legend 1500.000 1750.000 SLC - Sandy Lean Clay SS - Silty Sand SG - Sand and Gravel —V Interpreted Ground Water Table 2000.000 2250.000 2500.000 91,07"Riverside Technology, inc. Figure 3 Interpreted Cross Section 1 I I I I I I I I I I I I I I I I I I 0 *A * I CN4 7A jpjwS n�36 PE.OH-kUnI66 N A, CO S I t' L CO Ui 0 z C.0 0 LL IT C14 In 0 C > �2 Z P > N LL1 'Cc CC) 44- CL Ca 1. 0 tv . . .. I. I. . .. .. . ............. -0 .0 EL < . .. .. L) C: 0 CD Cc$ 0 (.) Z C E 0 CO m OD (D C3 �O C C If U) to (2) CTJ Cn , r 0 Cz :3 0 N Cj) (5 cis Co :3 w rL .2 rn U) `;; AQN3 A `� � l(� ; %' 1 �. o i i r� Riverside Technology, inc. Figure 2 401 ' `? ` ;( :; ��/,'>%, / j ��—i' �-� ��'� Lj 7 Potentiometric Surface 1 C C C C C 0 O O N of C C C y 7 O CO Cn J O U m 0 41 CO m Eo m a m (a Ca CO a)D Q '0N m a) hWel Riverside Technology, inc. Figure 1 Water Field Site Location Map I ' APPENDIX A Figures 1 1 F 1 1 1 RESOURCES Earth Engineering Consultants, Inc. (1996). Preliminary Subsurface Exploration Report, Country . Club Farms, Vine Drive and Summitview, Larimer County, Colorado. Landstar Surveying. (1997). Map of Piezometers and Staff Gage Locations. Fort Collins, Colorado. Riverside Technology, inc. (1996). Jurisdictional Wetlands Delineation Survey for the Country Club Farms L.L.C. Fort Collins, Colorado. Northern Engineering, Inc. (1997). Map of the site boundaries and topography. Fort Collins, Colorado. U.S. Department of Agriculture (USDA), Soil Conservation Service. (1993). Larimer County Area, Colorado: Comprehensive Hydric Soils List. ------ (1963 and 1978). Aerial photographs of the Waterfield P.U.D. site. USDA, Soil Conservation Service and Forest Service, in cooperation with the Colorado Agricultural Experiment Station. (1980). Soil Survey of Larimer County Area, Colorado. U.S. Department of the Interior, Geological Survey. (1960). 7.5-Minute Series Topographic Map for Fort Collins, Colorado, Quadrangle. U.S. Fish and Wildlife Service. (1975). National Wetlands Inventory Map for the Fort Collins, Colorado, Quadrangle. a42518weval.dac 04121197 5 function; however excessive amounts of sediment, oil and grease, or herbicides could be detrimental to the wetlands vegetation and wildlife. If stormwater runoff is diverted into the wetlands area, Best Management Practices (BMPs) should be implemented to reduce the amount of pollutants that reach the wetlands. BMPs could include using a grass -vegetated swale or depression that would provide a zone where the pollutants could adsorb onto the vegetation or settle out. ADDITIONAL STUDIES As project plans become more defined, it may be beneficial to obtain additional water level data and hydrogeological information. There are no ground water elevation data near the south or north side of the Larimer and Weld Canal. Additional piezometers and short-term aquifer tests (slug tests) in the vicinity of the canal or immediately downgradient from the canal would provide information to better define (1) interconnection between the canal and the water table and (2) the amount of seepage - from the canal. Additional piezometers located north of the canal (upgradient) could be used to obtain a better understanding of the regional ground water system. However this may not be possible since this area is under a different ownership. If additional information is collected to provide an understanding of (1) the existing hydrostratigraphic conditions, (2) ground water level data, (3) hydraulic conductivity of defined geologic units, and (4) construction design (utility trenches, subdrain and foundation layouts, etc.), it would be possible to implement a ground water model, such as MODFLOW, to predict or estimate how the water table will respond to site development plans. The model could also be used as a tool to evaluate the efficiency of subdrains and to estimate discharge rates. ' As mentioned previously, there is a ground water discharge area on the north side of the wetlands area with a flow of approximately 19 gallons per minute. This discharge may be an outlet for an underdrain system; however, there are no data to support this. If a drain system is encountered in ' this area, additional studies may be necessary to determine the source of the water and if any impacts to the wetlands area may occur by disturbing the drain system. 11 ' a4751sw�w1.dvc 04121197 4 ' Assu motions: ' • The ground water system below the project site is a component of the regional ground water system and includes seepage from the Larimer and Weld Canal. There is no ground water information available for the area near the canal or to the north (upgradient ) of the canal. ' • Ground water at borings B2 and B9 was encountered at a depth of 6 feet during drilling. No piezometers were installed at these sites, so a depth to ground water was assigned an elevation ' that corresponded to the 6-foot depth recorded during the time of drilling. • The potentiometric surface was based on average ground water elevations collected from September, 1996, to April, 1997. The wetlands pond is the result of a topographic low area that extends below the ground water surface (Figure 4 - Appendix A). The existing data indicate that ground water flows to the southwest ' beneath the site (Figure 2 - Appendix A). The ground water gradient was determined to be approximately 0.03 ft./ft. from piezometers B6 and B7 to the pond surface. ' The Larimer and Weld Canal, which borders the north boundary of the site, appears to have the capacity to convey a considerable amount of water. During April, 1997, the water depth in the canal was approximately 2 feet. The canal banks are composed of a silty clay covered with varying ' amounts of broken concrete. The canal width is approximately 100 feet at the top of bank and 50 feet at the bottom. If there is considerable seepage from the canal, the ground water gradient between the canal and the wetlands pond may become steeper as flows increase in the canal DISCUSSION ' The existing data indicate that the water level in the wetlands/pond area is maintained primarily by ground water discharge. As indicated on the cross sections in Appendix A, the source of the ground water may be from the regional ground water system, the Larimer and Weld Canal, or a combination ' of both sources. Lowering the ground water table is an option that has been considered to allow for the construction of basements. However, if the ground water table in the immediate vicinity of the pond is lowered ' below 4,949 feet, the wetlands area will most likely begin to dry up. ' If the ground water table is lowered but still retains a positive flow toward the wetlands pond, a reduction in the wetland size may still occur due to the flattening of the ground water gradient. A flatter gradient could reduce the rate of ground water discharge to the wetlands area. ' An option to maintain sufficient ground water flow to the wetlands area while still lowering the ground water system would be to place the underdrain outfall in the wetlands area. Another option ' to consider is using canal or well water to supplement in flow to the wetlands area. The current owner of the property has indicated that an adjudicated water right to canal water exists, as well as an adjudicated well. ' In addition, it might be possible to direct stormwater runoff from the development into the wetlands area to supplement the water source to the wetlands. Typically wetlands purify water by taking up nutrients and filtering sediment. The wetlands at the Waterfield site would provide this purifying ' o+2518weml.da MUM 3 . 0 u 1 1 L HYDROGEOLOGY EEC observed the presence of and depth to ground water while drilling and after completing each of the borings. Field piezometers were installed at six of the boring locations (B1,4,5,6,7, and 8) to allow for longer term monitoring of ground water levels. The piezometers consisted of 2-inch polyvinyl chloride pipe with slots in the bottom 5 feet. It does not appear that a gravel -pack back fill or surface seal was used to construct the piezometers. The locations of the piezometers are shown in Figures 1 and 2 in Appendix A. At the time of drilling, ground water depth was observed ranging from 5 to 7 feet below the present ground surface. Ground water levels were recorded at each of the piezometers during September, October, and November, 1996, and March and April, 1997. These data are summarized in Table 1. TABLE 1 Ground Water Elevations (Waterfield P.U.D.) Piezometer Number Ground Surface Elevation (feet) Ground Water Elevation (feet) 09/17/96 09/27/96 10/11/96 11/11/96 03/04/97 04/03/97 B 1 4957.19 4950.09 4949.66 4949.19 Dry Dry D* B2 4961.00 4955.00 -- -- -- -- -- B4 4961.05 4956.87 4956.57 4956.17 4955.47 4955.07 4955.06 B5 4955.94 4951.34 4951.07 4950.67 4949.92 4950.87 4949.28 B6 4959.45 4956.20 4956.6 4956.5 4956.25 4956.0 4956.03 B7 1 4965.41 1 4960.57 1 4959.97 4959.77 4959.13 1 4959.68 1 4959.45 B8 4952.92 4947.78 4946.98 4946.18 Dry Dry Dry* 139 4947.00 4941.00 -- -- -- -- -- *Piezometers were silted in: Bl to 4947.75 feet; B8 to 4945.93 feet Notes: Borings B3 and B10 did not encounter any ground water. Boring depths extend approximately 15 feet below ground surface. Piezometers were not installed in borings B2 and B9. Water levels were only recorded at the time of drilling. A staff gage was installed in the wetlands pond in April of 1997 to correlated the pond surface elevation with the existing ground water elevation (Figure 2 - Appendix A). The pond surface elevation was surveyed at 4,948 feet in April of 1997. Ground water seepage was observed flowing into a ditch that extends along the north and east side of the wetlands and then into the ponded area (Figure 1 - Appendix A). A flow measurement was taken in the ditch on April 14, 1997, using a portable flume. The flow was estimated at 0.04 cubic foot per second (cfs) or approximately 19 gallons per minute. ' The water level data, along with the assumptions listed below, were used to develop a potentiometric surface map and cross sections for the site (Figures 2-6 - Appendix A) and to analyze potential impacts to the wetlands area. ' u475/Rweml.doc 04121197 2 ' INTRODUCTION ' This report presents the results of Riverside Technology inc.'s (RTi's) preliminary evaluation of the ground water system at the Waterfield P.U.D. site located in the City of Fort Collins northwest of the intersection of Summit View and East Vine Drive. RTi understands that the site is under ' consideration for single and multi -family residential development. The purpose of this review is to evaluate the ground water system and determine if development activities may impact the wetlands area or require corrective measures. RTi s scope of work was limited to (1) compiling and analyzing existing data on the site, along with preliminary development plans provided by Northern Engineering Inc.; (2) installing a staff gage in the wetland pond to allow for a correlation between ground water elevations, flow in the canal, and pond surface elevation; and (3) presenting a summary of the ground water system at the site and any potential impacts that the project plans may have on the system, including the wetlands. ' SITE DESCRIPTION The majority of the Waterfield site consists of upland agricultural development: The terrain slopes ' gently to the south, with elevations ranging from approximately 4,950 to 4,980 feet. The Larimer and Weld Canal traverses the northern boundary of the property. A naturally occurring topographic low area has developed into a cattail marsh with ponded water that is 1 foot deep on average (Figure 1 - ' Appendix A). Excavations on the south side of the wetlands area appear to be in locations that, at one time, ' contained a tile drain system. Broken remnants of the tile drains were evident in the excavated areas. Mr. Bob Rudolf, who is currently farming the site, was contacted to obtain information on any drain systems that may have been installed. He was not aware of any existing drain systems, but felt that ' there was a high probability that some subsurface drains had been previously installed because of the shallow ground water system and the property's proximity to the Larimer and Weld Canal. ' SOILS AND SUBSURFACE CONDITIONS Ten soil borings extending to depths of 15 feet below present site grade were advanced by Earth Engineering Consultants Inc. (EEC). The subsurface exploration results are presented in the report entitled Preliminary Subsurface Exploration Report, Country Club Farms, Vine Drive and Summitview, Larimer County, Colorado (1996). A summary of EEC's observations of the ' subsurface conditions is provided below: Four to 6 inches of vegetation and/or topsoil was encountered at the surface of the boring locations. ' The topsoil/vegetation was underlain by brown and light brown sandy lean clay with varying amounts of silt. These soils extended to depths ranging from approximately 4 to 14 feet. The sandy lean clay was underlain by predominantly silt soils containing varying amounts of sand and clay or ' silty fine sands and ranged in depth from 9 to 14 feet. The fine grained sands and silts were underlain by granular soils, including varying amounts of sand and gravel. The granular soils extended to the bottom of the borings at depths of approximately 15 feet. The lithology of each ' boring is presented in Figures 3 through 7 - Appendix A. ' a425/Swewi.dac 0421N7 TABLE OF CONTENTS Section PRO Introduction..............................................................................................................................................1 SiteDescription.......................................................................................................................................1 Soilsand Subsurface Conditions............................................................................................................1 Hydrogeology..........................................................................................................................................2 Discussion...............................................................................................................................................3 AdditionalStudies....................................................................................................................................4 Resources...............................................................................................................................................5 APPENDIX A - Figures Figure 1 Water Field Site Location Map Figure 2 Potentiometric Surface Figure 3 Interpreted Cross Section 1 Figure 4 Interpreted Cross Section 2 Figure 5 Interpreted Cross Section 3 Figure 6 Interpreted Cross Section 4 List of Tables Table Page 1 Ground Water Elevations...........................................................................................................2 Ifl Preliminary Evaluation of the Ground Water System at the Waterfield P.U.D. Site submitted to City of Fort Collins and Northern Engineering Inc. by Riverside Technology, inc. 2290 East Prospect Road, Suite 1 Fort Collins, Colorado April 1997