HomeMy WebLinkAboutGLENMOOR DRIVE PUD - FINAL - 8-95B - CORRESPONDENCE - STAFF'S PROJECT COMMENTSN N This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please be aware of the following dates and deadlines to assure your ability to stay on schedule for the January 22, 1996 Planning and Zoning Board hearing: RR*AARR*ARRAR**RRk*kA*RR*RkkRRAAAAAAARRAA*RRAARRA**AARkARA**kA***A****kA*****kk Plan revisions are due by 5:00 p.m. on January 3, 1996. Please contact me for the number of folded revisions required for each document. Mrs, renderings, and 8 folded copies of final revisions are due by 3:00 p.m. on January 16, 1996. 1tfl RflAAR*f1AftAlt*flk RkflRRRf1f1RRA R*AA ARAARRRA AARRR**RAARRR**RAAR*RR**RAAA*RAAARRk RRRR Please contact me at 221-6206 if you have any questions or concerns related to these comments. I would like to schedule a meeting with you as soon as possible, if necessary, to discuss these comments. Sincerely, NLchael Ludwig Project Planner xc: Jeff Couch, P.E. Kerrie Ashbeck Stormwater Utility file/Project Planner N 5. The Light and Power Utility states the following: a. The ash trees along Glenmoor Drive will need to conform to the tree/streetlight standards. b. Provisions need to be made for utilities to cross the box culvert. C. The placement of electrical meters on the buildings needs to be coordinated with the Light and Power Utility. Please contact Bruce Vogel at 221-6700 to discuss this comment. 6. The Planning Department offers the following comments. a. Several comments have been made by reviewing agencies and by the Planning and Zoning Board at the Preliminary P.U.D. hearing regarding a difficulty in reading the plans. Staff feels that the combined Site/Landscape Plan provides to much information for one sheet. Please separate the Final Site/Landscape Plan into a Final Site Plan (Sheet 1 of 3) and Final Landscape Plan (Sheet 2 of 3). Label the building elevations as Sheet 3 of 3. b. Preliminary PUD approval was granted for a minimum of 16 dwelling units (8 duplex structures) or a maximum of 22 dwelling units (6 triplex structures and 2 duplex structures). The Final PUD should reflect what will actually be built. Please reflect the actual number of dwelling units and type of structures which will be built. 7. The Water and Wastewater Utility states the following comments: a. The water main connection to Plum street must be offset (show it offset) from tee. b. Need to pothole utilities now to verify locations in order to achieve a complete design. C. Please coordinate the landscape plan with the utility plans to provide 10' separation of trees and 4' separation of shrubs from water and sewer mains and services. d. Are there any irrigation taps proposed. 8. Engineering Department comments are forthcoming (plans were not submitted until 11/30/95). 9. Stormwater Utility comments forthcoming (plans were not submitted until 11/30/95). Comm 1 Planning and EnvironmentalNces Current Planning City of Fort Collins December 15, 1995 Robert K. Glover 1005 Country Club Road Fort Collins, CO 80524 Dear Kint, Staff has reviewed your documents for the Glenmoor Drive P.U.D., Final that were submitted on November 20, 1995, and would like to offer the following comments: The Mapping Department questions whether this P:U.D. will be confused with the Glenmoor PUD. It is suggested that the name of this PUD be Glenmoor Second PUD or something similar for better clarity. 2. Public Service of Colorado stated the following: a. Utility easements need to be such that from the back of walk to the rear line the easement is 13 feet minimum. b. No trees are allowed within 4' of gas lines. There may be a potential conflict with street trees. 3. The Zoning Department states the following: a. Please indicate the distances from building envelopes to the lot lines. Since the lots are different sizes and shapes, this will have to be shown for each lot. Another option would be to eliminate the building envelopes and just have a building setback table (i.e. 20' front, 5' side, 15' rear, etc). b. Please revise the landscape note to state "Landscaping and irrigation system for common areas shall be installed or secured with a letter of credit, escrow..........." 4. The Building Inspections Department states: "The Plat indicates that the project consists of duplex and triplex residential units on individual lots. Duplex buildings are classified as R- 3 Occupancies as defined in the building code and triplex buildings are R-1. Provide required distances to property lines from exterior walls or fire -resistive wall constructions and opening protection for doors and windows. Construct architectural projections in accordance with building code requirements. It is unclear why building envelopes are designated if the building footprint is already determined. 281 North College Avenue • P.O. Box 580 Fort Collins, CO 80522-0580 • (970) 221-6750 FAX (970) 221-6378 TDD (970) 224-6002