Loading...
HomeMy WebLinkAboutREGISTRY RIDGE, 4TH FILING - PDP - 32-95G - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCE-CONCEPTUAL REVIEW,yn P% �16-00 10:32A P.O9 13. This development. proposal is subject to the requirements as set forth iri the City's LUC, specifically Articles 2. Administration (Development Review Procedures), Article. 3. General Development Standards, and Article 4. JZoning] Districts. ,, 16-00 10:31A P.08 e. Fire flows of 1,000 gallons per minute at a residual pressure of 20 pounds per square inch must be provided, f'. As t.hr. a.ppiicant's design development is completed, emergency access to the site and addressing of the dwelling units should be coordinated with the Pottdre Fire Authority. Plca.se contact Ron, at 221-6570, if you have questions about these comments. 10. At the COnceptLial Review meeting it was suggested that the applicant and City staff meet to discuss the proposed narrow street Width issue and the implications associated with such as: the street width, • Dwelling unit addressing • Emergencv access • Parking, both on -site and potentially off -site • Compliance with Section 3.5.2(C) Orientation to a Connecting Walkway Based on the position taken by Engineering and Transportation Planning, that. the reduced width streets will not. work and will not be supported, staff has determined that a meeting to discuss this issue would not be productive at this time. Internal streets designed to the City ;,S Street Design Standards will satisfy [lie aforementioned Concerns. 11. At Conceptual Review it was stated by the applicant that the Property is 8.2 acres in size. Based on the requirements as set forth in Section 4.4(D)(1)(a) of the LUC, meeting the minimum net density requirement of 5 dwelling units per acre would allow for the applicant t.o drop the proposed number of dwelling units to 41. This would potentially allow for the wider, compliant streets and maintain the proposed open space. 12. This development request will be subject to the City's development review fee and the Fee Schedule rhat is available in the Current Planning Department office. The fee is due at the time of subrriitt:al of the required documents for the Project Development Plan and the Final Compliance phases.of development. review by City staff and affected outside reviewing agencies. +_ ..16-00 10:31A P•0J 7. Mark ,Jackson of the Transportation Planning Department offered the following comments: a. Bon Homme Richard Drive will be a collector street. b. An update of the Registry Ridge TIS will be required with your PDP submittal Please contact Eric Bracke of the Traffic Operations Department, at 224-6062, and Mark, at 416-2029, to determine what information is needed in the TIS pertaining to Level of Service for vehicle, pedestrian, bicycle, and transit modes of transportation. C. Enhanced treatment for pedestrian crosswalks at Enterprise Drive and at the round -about at Nimitz Drive should be considered. The, Traffic Operations Department will make the determination aboutthe nature of the enhancement. d. Bicycle and pedestrian connections should be provided within the development and to surrounding properties. Please contact. Tom. at 416-2040. if you have questions about these comments. $. Alison Brady of the Parks Planning Department stated that the residential portions of this development. will be subject: to the City's neighborhood and community parkland fees. The fees will be assessed on each dwelling unit and. are based on the square footage of the unit. 9. Ron Gonzales of the Poudre Fire Authority offered the following comments: a. The addresses on the buildings must be visible from a street. b. The roadway must be maintained as a 20' wide unobstructed access way. C. Emergency access into this development will be an issue. d. A fire hydrant must be within 400' of all buildings and hydrants mLlst be spaced at 800' on -center. AUG-16-2000 11:31 97% P.07 16-00 10:31A P.06 ' 4� e On -site extended detention is required to treat the runoff. Please contact Glen, at 224-6065, if you have questions about these comments. S, Doug Martine of the Light & Power Department offered the following comments: �. Will there be adequate space for all the necessary utilities? There must be a 10' separation between water, sanitary sewer, and electric. All utilities must be coordinated, including the services to the dwelling units. b. Please be aware of, and provide for, the required street tree £� utilities separation distances. C. The normal electric charges will apply to this development. Please: contact Doug, at 224-6152, if you have questions about rhesc comments. e�. Kim Kreirneyer, the City's Natural Resources Planner, offered the following comments: a. Il' there are prairie dogs on this site they musr be relocated or humanely eradicated prior to any construction occurring. b. A Fugitive Dust Control Pl'mit must be issued by the La.rimer County Environmental Health Department. Please contact them directly for information about their rcquiremen ts. C. Bicycle and pedestrian connections should be provided within the development and to surrounding properties. d. Native plant materials and grasses should be incorporated in the Landscape Plan for this development. C. The trash dumpsters, if proposed, should be designed and constructed to provide for recycling. Please contact Kim, at 221-6641, if you have questions about these comments. AUG-16-2000 11:70 OOY n nr 16-00 10.31A P-05 find parking internally eventually park illegally on a public street and, sometimes, get ticketed. They usually are not very happy and call the Transportation Planning Departmenr.. Also, this obstructs the on - street bike lanes. f. The private drive layout will create problems with addressing of the dwelling units. y. The standard utility plan submittal requirements will apply to this development request. h. With the potential traffic intensity being a point of discussion, an updated Transportation Impact Study (TIS) will be required with the PDP submittal. Please contact Eric Bracke of the; Traffic Operations Department, al. 224-6062, and Marl:, at 416-2029, to determine what information is needed in the TIS pertainin17 to Level of Service for vehicle, pedestrian, bicycle, and transit modes of transportation. Please contact Marc, at 221-6750, if you have questions about these comments. :3. Roger Buffington of the Water/Wastewater Department stated chat service in this area will be provided by the Fort Collins - Loveland Water District and the Sour.h Fort Collins Sanitation District. 4. Glen Schlueter of the Storrnwater Utility offered the following comments: a. The site is located in the Fossil Creek Drainage Basin, where the development fee is $2,274 and subject to the runoff coefficient reduction. The site: is in Inventory Grid #51J. b. The Registry Ridge, 1st Filing drainage report and construction plans designed the drainage system Cor this site. However, the new rainfall criteria will need to be applied to this site. Therefore, the detention pond may need to be larger than originally designed -The necessary drainage. report and construction plan update must be prepared by a professional engineer registered in the State of Colorado. RU5-16-2000 11:30 97% P.05 16-00 10:30A P.04 b. Street oversizing fees will apply .to this development. These fees are based on vehicle trip generations for the proposed land uses in the development plan. Please contact Matt .Baker, at 224-6108, for detailed information on the fees. C. All incomplete infrastructure along the streets in this overall development must be completed with this filing of development. d. All required utility easements must be included on the subdivision plat. e. The proposed reduced width of the internal public streets, from 30' to 24' and prohibiting parking on the street, will not work and will not be supported. • With the proposed duplex use the traffic could be more intenae than multi-(amily as it is closer to a single family detached use than multi -family. It is possible that these duplexes, each unit with a 2-car garage, will house larger families that have multiple cars. The potential overflow parking will have to go somewhere.. By allowing public srreets at a reduced width that does not allow parkin;, it is very possible that there would be inadequate on -sire parking and the overflow parking would potentially go to Bon Homme Richard Drive. This street will be a collector without: parking and the overflow parking could, therefore, go into the . on -street bike lanes. Also, enforcement of no parking on the reduced width 24' internal streets could become an issue. • Perhaps the largest issue with the reduced street width, more than Poudre Fire Authority's concerns about access and addressing, is not having parking on the internal streets. The Transportation Planning Department has, brought up numerous situations in the past where an inadequate internal roadway network (usually private drives) in multi -family developments often causes parking to spill over onto the adjacent public street network. Often times, the parking spills onto a public street that has bike lanes but no parking and, as a result, people who cannot ti_ 16-00 1O:3OA P-03 �r b. Building envelopes for the duplex structures must be delineated and described (scaled distances to property lines) on the Site Plan. C. 'Typical building elevations for the duplex structures must be submitted with the Project Development (PUP) plans, d. Landscaping, including street trees, must comply with Section 3.2.1 of the LUC. A "typical" lot and building foundation landscape plan could/should be provided. c. For a project of this size (just over 8 ,acres) it will bc, best to do a I -phase Landscape. Plan and indicate Lhis in the notes on the plan. f. flow is trash pick-up' going to occur in Lhis development? Will there be central trash enclosures or curbside pick-up? g. This development proposal must. comply with the applicable General Development Standards as set forth in Article 3 of the LUC. h. This development proposal must comply with the Land Use Standards and Development Standards as set forth in Division 4.4 - LMN District of the LUC. Specifically, Section 4.4(D)(1) Density in the LMN - Low Density Mixed -Use Neighborhood District of the LIJC sets fort.h the requirements for the minimum and maximum densities on a development plan. Please contact ,Jenny, at 221-6760, if you have questions about these comments. 2. Marc Vira t.a the Engineering Department offered the following comments: a. This parcel of land was/is not included in the any of the previous Registry Ridge subdivision plats. Therefore, a. subdivision plat for this property must be included as part of the PDP submittal for this development request. RUG-16-2000 11:29 97_ P.03 16-00 10:30A zw•f.4 CONCEPTUAL REVIEW STAFF CO(NINIENTS City of Fort Collins MEETING DATE: August 14, 2000 ITEM: Registry Ridge, 4th Filing -Duplex Resiclenlial APPLICANT: VF Ripley Associates, Inc. c/o Linda Ripley CFO 1 West Mountain Avcnue, Suite 201 Fort Collins, CO 80521 LAND USE DATA: Request for 46 duplex dwelling units (in 23 buildings) on 8.2 acres located at. southwest. corner of Sowh Shields Street and Bon Homme Richard Drive. The property is in the LINJN - Low Density Mixed -Use Neighborhood Zoning District. COMMENTS: ,Jenny NUCkols of the Zoning Department offered the following 00mmcnr.s: a. The property is in the LMN - Low Density Mixed -Use Neighborhood Zoning District in the City of Fort Collins Land Use Codc (LUC). • The proposed duplex residential use is permitted in the. LMN District, and would be subject to an administrative ('lope I) review and public hearing. If all of the applicable standards in the LUC cannot be met, then either an Alternative Compliance plan or a Modification to a Standard requcst must be submitted for review. A Modification to a Standard would "bump" the development request to a Planning and Zoning Board (Type II) review and public hearing. ?.1\•ll:Nt'1.)('1.AVNINC: ANI1IfNV1Rtln',HLNT:1,1.5L'ItVI('i:s =4;'. Nv'' CtI 11"N.i.<II F",rk .ali�1•., C.O RIi,�:i,^, Il:..il) ('+ III __I•n:`11 RUG-16-2000 11:29 97% P.02 Aug-16-00 10:30A (006� ,A=dm Citv of Fort Collins Community Planning and Environmental Services Current I'Liniiiii-, August 15, 2000 VF Ripley Associates, Inc. c/o Linda Ripley 401 West. Mountain Avenue, Suite 201 Fort Collins, CO 80521 Dcar Linda, P-01 Post -It` Fax Note 7671 Male At U 111 US To, , From CiOJ o 1 C , Phone A Phnne N Fax a F ak # For your information, attached is a copy of the Staffs comments concerning the request for Registry Ridge, 4th Filing - Duplex Residential, which was presented before I.he Conceptual Review Team on August 14, 2000. This is a request 1'()r 46 duplex dwelling units (in 23 buildings) on 8.2 acres located at southwest corner of South Shields Street and Bon Hummc, Richard Drive. The property is in the LMN — Low Density Mixed - Use Neighborhood Zoning Distri<:L. The comments are offered informally by Staff to assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 221-6341. Si cercly, S*Oh, Project Planner cc: Cameron Gloss, Current Planning Director St.ormwater Utility Streets File li-,\ ,80 • F,irt Gplli . 0) 11;^ �r' 7� - ttr 3 __-II,�ti11 ( 701:_1-li,5I) • F:•1X 1`70)-I1n-_070 AUG-16-2000 11:29 9?% P.01 7. Transportation Planning Department a. Noted b. See traffic study c. See site plan d. See site plan 8. Parks Planning Department 9. Poudre Fire Authority a. Noted b. Noted c. See site plan d. Noted e. Noted f. Meeting was established on August 21, 2000, to discuss these issues. 10. Because staff was not in support of the 24' road width, they would not schedule a meeting to discuss further options. 11. Noted 12. Noted 13. Noted Sincerely, achel Linder Project Manager VF Ripley Associates September 8, 2000 Steve Olt Project Planner 281 North College Ave. Fort Collins, CO 80522 Dear Steve Olt, The comments below address the issues raised at the Registry Ridge Fourth Filing Conceptual Review meeting on August 14, 2000. 1. Zoning Department: a. Type I review b. See site plan c. See architectural elevations d. See landscape plan e. See plant notes on landscape plan f. There will be curbside trash pick-up. g. See submittal h. See submittal 2. Engineering Department a. See plat b. Street oversizing fees c. All street infrastructure will be completed with this filing. d. See plat e. The internal street is at a width of thirty feet. f. The internal street will be public therefore having a name and address will no longer be an issue. g. See utility plan h. See traffic study 3. Water/Wastewater Department 4. Stormwater Utility a. Noted b. See engineering plans c. See engineering plans 5. Light and Power Department a. See utility plan b. See landscape plan c. Noted 6. Natural Resources Planner a. Noted b. Noted c. See site plan d. See landscape plan e. No trash dumpsters