HomeMy WebLinkAboutHEARTHFIRE (HOFFMAN) PUD - PRELIMINARY - 31-95A - CORRESPONDENCE - (7)Please contact me at 221-6750 if you have questions or concerns related to these comments. I would like to schedule a meeting with you as soon as possible, if necessary, to discuss these comments. Sincerel Steve Olt Project Planner xc: Kerrie Ashbeck/Sheri Wamhoff Stormwater Utility Transportation Please provide justification for the points taken in the Bonus section of the Residential Density Chart. The points taken for Bonus criteria m, n, p, and q are very difficult to understand and support. How much area is being considered "recreational use" and how does that meet the City's definition of Recreational Space in the L.D.G. S.? What areas) are considered to be "permanent off -site open space" and how can this percentage be so high? How will the commitment to this be assured? What neighborhood facilities and services not otherwise required by City code are being proposed? How will the commitment to a percentage of the dwelling units to be for low income families be assured? Base criterion j - contiguity to existing urban development - cannot be varied. The density chart will have to be discussed thoroughly. Staff has concerns about whether this development can meet the minimum requirements based on the location of the proposed development at this time and place. 4. The Vicinity Map on the Site Plan shows a potential connection to Serramonte Highlands but the subdivision plat does not. What is the intent for and who owns the "public access"? The Stormwater Utility has concerns about the wetlands. They appear to be perched, with no outlets. Are basements being planned? Groundwater infiltration may be a problem. A hydrologic study maybe should be done now. The affected ditch company will have to approve and sign the utility plans. This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please be aware of the following dates and deadlines to assure your ability to stay on schedule for the August 21, 1995 Planning and Zoning Board hearing: Plan revisions are due no later than the end of the working day, August 3, 1995. Please contact me for the number of folded revisions required for each document. PMT's (photo reduction of site Plan, Landscape Plan, Building Elevations to 8.5" x 11")9 rendering (one each colored full-size Site u Landscape Plan and Building Elevations), and 8 folded copies of the final full-size Site Plan, Landscape Plan, and Building elevations revisions ( for the Planning and Zoning Board members packets) are due on August 14, 1995. *aa**a***a�**a**a*********w**a�x�c***aaa�e*�**past*ft**************a�ese*****��*s•�ee L �< July 17, 1995 Commui l Planning and Environmental, vices Current Planning Jim Sell Jim Sell Design 117 East Mountain Avenue Fort Collins, CO. 80524 Dear Jim, The following comments for the Hoffman O.D.P. and the Hoffman P.U.D., Preliminary are in addition to the comments dated July 12, 1995 that were previously sent to you: Overall Development Plan: Public Service Company has stated that easement widths adjacent to County Road rights -of -way and internal streets must be adequate for all utilities. Preliminary P.U.D.: The following comments have been received from Public Service Company: a. Utility easement widths adjacent to street rights -of -way must be such that from the back of walk to the rear line of the easement is 13' minimum. b. Utility easements adjacent to rights -of -way must also be along all tracts, as well as .all lots. C. Any reroute/abandonment of existing PSC facilities due to this development will be at the developer's expense. 2. Columbine CableVision has stated that "marked in pink are the areas we will need utility easements. We would also need the tracts marked in blue as open space and utility easements". They are obviously referring to a document that I do not seem to have. I would suggest contacting Dennis Greenwalt at the cable company for clarification on this comment. 281 North College Avenue • P.O. Box 580 Fort Collins, CO 80522-0580 • (970) 221-6750 FAX (970) 221-6378 TDD (970) 224-6002