HomeMy WebLinkAboutHEARTHFIRE (THE POND AT) SUBDIVISION - PRELIMINARY - 31-95B - SUBMITTAL DOCUMENTS - ROUND 1 - GEOTECHNICAL (SOILS) REPORTPreliminary Geotechnical Engineering Exploration Merrick & Company TCW Project No. 20955191 Terracon conditions encountered at the site, it is recommended that additional test borings be made prior to final design. Samples obtained from the borings should be tested in the laboratory to provide a basis for evaluating subsurface conditions. This report has been prepared for the exclusive use of our client for specific application to the project discussed and has been prepared in accordance with generally accepted geotechnical engineering practices. No warranty, express or implied, is made. This report has been prepared to aid in the evaluation of the property and to assist the architect and/or engineer in the preliminary design of this project. This report is for the exclusive purpose of providing preliminary geotechnical engineering and/or testing information and recommendations. The scope of services for this project does not include, either specifically or by implication, any environmental assessment of the site or identification of contaminated or hazardous materials or conditions. If the owner is concerned about the potential for such contamination, other studies should be undertaken. 9 Preliminary Geotechnical Engineering Exploration Terracon Merrick & Company TCW Project No. 20955191 U, = 15to25xD Where: Up = the uplift force in kips, and D = the pier diameter in feet Basement Construction: Groundwater was encountered on the majority of the site at depths of 6 to 14 feet below existing grade. Full -depth basement construction is considered feasible on the site provided that basement subgrade is a minimum of 3 feet above existing groundwater. Finished basement slabs should be placed a minimum of 3 feet above the bedrock stratum. A complete dewatering system should be provided around the basement area. Perched groundwater may occur at times since the subsurface soils are relatively impermeable and tend to trap water. Completion of site development, including installation of landscaping and irrigation systems, will likely lead to perched groundwater development. To reduce the potential for groundwater to enter the basement of the structure, installation of a dewatering system is recommended. The dewatering system should, at a minimum, include an underslab gravel drainage layer sloped to a perimeter drainage system. Floor Slab Design and Construction: The variability of the existing soils at approximate slab subgrade elevation could result in differential movement of floor slab -on -grade should expansive soils become elevated in moisture content. Use of structural floor systems, structurally supported independent of the subgrade soils, is a positive means of eliminating the potentially detrimental effects of floor movement. • Compliance: Recommendations for slabs -on -grade, foundations and pavement elements supported on compacted fills or prepared subgrade depend upon compliance with "Earthwork" recommendations. To assess compliance, observation and testing should be performed under the direction of the geotechnical engineer. PRELIMINARY GENERAL COMMENTS It should be noted this was a preliminary investigation and the foundation systems recommended in this report are based on preliminary tests. Due to variations in soil 8 Preliminary Geotechnical Engineering Exploration Merrick & Company TCW Project No. 20955191 Terracon 4. On -site clay soils may pump or become unstable or unworkable at high water contents. Workability may be improved by scarifying and drying. Overexcavation of wet zones and replacement with granular materials may be necessary. Lightweight excavation equipment may be required to reduce subgrade pumping. • Fill Materials: 1. On -site clay soils are suitable for use beneath slabs or as backfill. 2. On -site bedrock materials are not recommended for use beneath structural ares of the site, or as backfill. Should bedrock materials be used for general site grading, placement in fills at non-structural locations on the site is recommended. Foundation Systems: Due to the presence of moderate of high swelling soils on the site, spread footing and/or grade beam foundations bearing upon undisturbed subsoils and/or engineered fill are recommended for support for the proposed structures. Consideration should be given to using drilled pier foundations for structures founded partly on the bedrock stratum and partly in the clay soils. Additional testing should be done prior to final design. Based on preliminary test results, footing and/or grade beams founded on the undisturbed soil should be designed for a maximum allowable bearing capacity of between 2,000 to 4,500 pounds per square foot (dead load plus 1/2 live load). To counteract swelling pressures which will develop if the subsoils be wetted, all footings should be designed for a minimum dead load pressure of 500 to 1,500 per square foot. Where drilled pier foundation systems are used, the piers would have minimum 12 to 15 foot lengths and extend a minimum of 5 feet into the bedrock stratum. Based on preliminary test results, the piers should be designed for a maximum end bearing pressure of between 15,000 to 30,000 psf and skin friction of 1,500 to 3,000 psf. For preliminary design purposes, the uplift force on each pier can be determined on the basis of the following equation. 7 Preliminary Geotechnical Engineering Exploration Terracon Merrick & Company TCW Project No. 20955191 • Site Clearing: 1. Strip and remove existing vegetation, debris, and other deleterious materials from proposed building and pavement areas. All exposed surfaces should be free of mounds and depressions which could prevent uniform compaction. 2. If unexpected fills or underground facilities are encountered during site clearing, such features should be removed and the excavation thoroughly cleaned prior to backfill placement and/or construction. All excavations should be observed by the geotechnical engineer prior to backfill placement. 3. Stripped materials consisting of vegetation and organic materials should be wasted from the site, or used to revegetate exposed slopes after completion of grading operations. If it is necessary to dispose of organic materials on - site, they should be placed in non-structural areas, and in fill sections not exceeding 5 feet in height. 4. All exposed areas which will receive fill, once properly cleared and benched where necessary, should be scarified to a minimum depth of 6 inches, conditioned to near optimum moisture content, and compacted. • Utility and Site Grading: 1. It is anticipated that excavations for the proposed construction can be accomplished with conventional earthmoving equipment. 2. Excavations penetrating the well -cemented sandstone bedrock may require the use of specialized heavy-duty equipment, together with drilling and blasting, ripping or jack -hammering to facilitate rock break-up and removal. 3. Depending upon depth of excavation and seasonal conditions, groundwater may be encountered in excavations on the site. Groundwater seepage should be anticipated for excavations approaching the level of the bedrock. Pumping from sumps may be utilized to control water within excavations. Well points may be required for significant groundwater flow, or where excavations penetrate groundwater to a significant depth. 6 Preliminary Geotechnical Engineering Exploration Merrick & Company TCW Project No. 20955191 Terracon Field and Laboratory, Test Results: Field and laboratory test results indicate the clay soils are medium to very stiff in consistency and exhibit moderate to high bearing characteristics and moderate to high swell potential. The bedrock is moderately hard to hard and cemented to well cemented and exhibits very high bearing characteristics and low swell potential. Groundwater Conditions: Groundwater was encountered in Boring 2 at the time of drilling and when checked 1 to 10 days after drilling, groundwater was encountered in Borings 2 through 6 at approximate depths of 6 to 14 feet. Boring 1 remained dry. These observations represent groundwater conditions at the time of the readings, and may not be indicative of other times, or at other locations. Groundwater levels can be expected to fluctuate with varying seasonal and weather conditions. Zones of perched and/or trapped groundwater may also occur at times in the subsurface soils overlying bedrock, on top of the bedrock surface or within permeable fractures in the bedrock materials. The location and amount of perched water is dependent upon several factors, including hydrologic conditions, type of site development, irrigation demands on or adjacent to the site, fluctuations in water features, seasonal and weather conditions. Fluctuations in groundwater levels can best be determined by implementation of a groundwater monitoring plan. Such a plan would include installation of groundwater monitoring wells, and periodic measurement of groundwater levels over a sufficient period of time. The possibility of groundwater fluctuations should be considered when developing design and construction plans for the project. PRELIMINARY CONCLUSIONS AND RECOMMENDATIONS Site Development Considerations: The site appears suitable for the proposed construction. Although fill or underground facilities, such as septic tanks, cesspools, basements and utilities, were not observed during site reconnaissance, such features might be encountered during construction. 5 T JPreliminary Geotechnical Engineering Exploration Terracon Merrick & Company TCW Project No. 20955191 The regional dip of the Pierre shale in this area is slight and in an easterly direction. Seismic activity in the area is anticipated to be low; therefore, from a structural standpoint, the property should be relatively stable. It is anticipated that the weathered bedrock and the J majority of the firm bedrock may be excavated by conventional heavy-duty construction equipment equivalent to a D-8 tractor and ripper or a large track -mounted backhoe. However, the sandstone becomes dense at lower depths. This dense sandstone at depth 7 may require the use of special heavy-duty excavation equipment or possibly blasting for J excavation. Due to the relatively flat to gently -rolling nature of the site, geologic hazards due to mass movement caused by gravity, such as landslides, mudf lows, rockfalls, etc., are not anticipated. With proper site grading around structures and proper drainage for streets and drive areas, erosional problems at the site should be minimal. It is recommended that construction not be placed within the wet areas in the central portion of the site without proper draining and filling. The site is underlain by the Cretaceous Pierre Formation. The Pierre shale is not known to contain economic deposits of coal, limestone, or quarry rock. Sand and gravel was not encountered at the site, and economic deposits of these materials are not anticipated. Background levels of radioactivity are anticipated to be low in this area. However, the possibility does exist that abnormally high radiation rates may exist on the property. A detailed study of radon gas or radiation hazards at the site is beyond the scope of this report. It is suggested that a more detailed study be made prior to construction to more accurately determine if radiation hazards exist at the site. Soil and Bedrock Conditions: As presented on the Logs of Boring, the subsurface soils were encountered in order of increasing depths. • Silty Topsoil: The area tested is overlain by a 6-inch layer of silty topsoil. The topsoil has been penetrated by root growth and organic matter. • Sandy Lean Clay: This stratum underlies the topsoil and extends to the bedrock it below and/or the depths explored. The sandy lean clay is plastic, dry to wet and medium to very hard. • Sandstone-Siltstone Bedrock: The bedrock was encountered in Borings 2, 5 and 6 at depths of '/Z to 13 feet and extends to greater depths. The upper 1 to 1'/z feet of the bedrock is highly weathered; however, the underlying sandstone interbedded with claystone is well -cemented and hard. 0 0 Preliminary Geotechnical Engineering Exploration Terracon Merrick & Company TCW Project No. 20955191 • Water content • Expansion • Dry density • Atterberg limits The significance and purpose of each laboratory test is described in Appendix C. Laboratory test results are presented in Appendix B, and were used for the geotechnical engineering analyses, and the development of foundation and earthwork recommendations. All laboratory tests were performed in general accordance with the applicable ASTM, local or other accepted standards. SITE CONDITIONS The site surrounds an existing lake and wetlands areas. The area is vegetated with native grass and Russian olive and cottonwood trees and brush. Cattails were noted growing in the wetlands area. Fences are located throughout the property along with several oil wells. The site is bordered on all sides by fenced pasture land. Drainage, in general, is from the north, south, east and west toward the lake and wetlands in the center of the project. The property is bordered on the west by Larimer County Road 13, on the southwest by Richards Lake, and on the north and east by open pasture. SUBSURFACE CONDITIONS Geoloay: The proposed area is located within the Colorado Piedmont section of the Great Plains physiographic province. The Colorado Piedmont, formed during Late Tertiary and Early Quaternary time (approximately 2,000,000 years ago), is a broad, erosional trench which separates the Southern Rocky Mountains from the High Plains. Structurally, the site lies along the western flank of the Denver Basin. During the Late Mesozoic and Early Cenozoic Periods (approximately 70,000,000 years ago), intense tectonic activity occurred, causing the uplifting of the Front Range and associated downwarping of the Denver Basin to the east. Relatively flat uplands and broad valleys characterize the present-day topography of the Colorado Piedmont in this region. The site is underlain by the Cretaceous Pierre Formation. The Pierre shale at the site consists of sandstone and claystone. Bedrock was encountered in Borings 2, 5, and 6 at depths of Yz to 13 feet, and it is anticipated it underlies the remainder of the site at depths of 20 to 25 feet. The bedrock is overlain by residual and alluvial clays of Pleistocene and/or Recent Age. A Geologic Map, Soil Map and legend are included in Appendix A. 3 Preliminary Geotechnical Engineering Exploration Terracon Merrick & Company TCW Project No. 20955191 SITE EXPLORATION The scope of the services performed for this project included site reconnaissance by a geotechnical engineer and an engineering geologist, a subsurface exploration program, laboratory testing and engineering analysis. Field Exploration: A total of 6 test borings were drilled on July 6, 1987 and October 31, 1995 to depths of 15 feet at the locations shown on the Site Plan, Figure 1. The borings were drilled within the area of proposed buildings. All borings were advanced with a truck - mounted drilling rig, utilizing 4-inch diameter solid stem auger. The borings were located in the field by pacing from property lines and/or existing site features. Elevations were taken at each boring location from a topographic map prepared by Merrick & Company. The accuracy of boring locations and elevations should only be assumed to the level implied by the methods used. Continuous lithologic logs of each boring were recorded by the geotechnical engineer during the drilling operations. At selected intervals, samples of the subsurface materials were taken by means of pushing thin -walled Shelby tubes, or driving split -spoon samplers. Penetration resistance measurements were obtained by driving the split -spoon into the subsurface materials with a 140-pound hammer falling 30 inches. The penetration resistance value is a useful index to the consistency, relative density or hardness of the materials encountered. Groundwater measurements were made in each boring at the time of site exploration, and 1 to 10 days after drilling. Laboratory Testing: All samples retrieved during the field exploration were returned to the laboratory for observation by the project geotechnical engineer, and were classified in accordance with the Unified Soil Classification System described in Appendix C. Samples of bedrock were classified in accordance with the general notes for Bedrock Classification. At that time, the field descriptions were confirmed or modified as necessary, an applicable laboratory testing program was formulated to determine engineering properties of the subsurface materials. Boring logs were prepared and are presented in Appendix A. Selected soil and bedrock samples were tested for the following engineering properties: 2 PRELIMINARY GEOTECHNICAL ENGINEERING REPORT Terracon THE POND AT HEARTHFIRE DOUGLAS ROAD AND COUNTY ROAD 13 FORT COLLINS, COLORADO TCW Project No. 20955191 April 22, 1996 INTRODUCTION This report contains the results of our preliminary geotechnical engineering exploration for the proposed first filing of The Pond at Hearthfire located at the southeast corner of Larimer County Road 13 and Douglas Road, northeast of Fort Collins, Colorado. The site is located in the West 1 /2 of Section 30, Township 8 North, Range 68 West of the 6th Principal Meridian. The purpose of these services is to provide preliminary geotechnical engineering information relative to: • subsurface soil and bedrock conditions • groundwater conditions • earthwork • preliminary foundation systems • basement construction • preliminary floor slab design and construction • utilities The conclusions and recommendations contained in this report are based upon the results of limited field and laboratory testing, engineering analyses, and experience with similar soil conditions and structures and our understanding of the proposed project. Prior to final design, additional studies will be required. PROPOSED CONSTRUCTION The site will be developed as a residential subdivision with single-family and multifamily housing. Residential streets will be constructed throughout the project area. Grading plans were not available at the time of preparation of this report, and it is anticipated that some cut and fill will be required. Preliminary Geotechnical Engineering Exploration Terracon Merrick & Company TCW Project No. 20955191 TABLE OF CONTENTS (Cont'd) APPENDIX A Figure Nos SitePlan ................................................. 1 GeologicMap ............................................. 1 SoilsMap ................................................ 1 Logs of Borings ..................................... Al thru A6 Legend.................................................. 7. APPENDIX B Summary of Test Results .................................... B1 APPENDIX C: GENERAL NOTES Drilling & Exploration ........................................ C1 Unified Soil Classification .................................... C2 Bedrock Classification, Sedimentary Bedrock ....................... C3 Laboratory Testing, Significance and Purpose ...................... C4 Report Terminology ........................................ C5 Preliminary Geotechnical Engineering Exploration Terracon Merrick & Company TCW Project No. 20955191 TABLE OF CONTENTS Page No. Letter of Transmittal ............................................... ii INTRODUCTION ................................................ 1 PROPOSED CONSTRUCTION ....................................... 1 SITE EXPLORATION ............................................. 2 Field Exploration .......................................... 2 Laboratory Testing ......................................... 2 SITE CONDITIONS .............................................. 3 SUBSURFACE CONDITIONS ....................................... 3 Geology................................................ 3 Soil and Bedrock Conditions .................................. 4 Field and Laboratory Test Results ............................... 5 Groundwater Conditions ..................................... 5 PRELIMINARY CONCLUSIONS AND RECOMMENDATIONS .................. 5 Site Development Considerations ............................... 5 Site Clearing ........................................ 6 Utility and Site Grading ................................. 6 Fill Materials ........................................ 7 Foundation Systems ........................................ 7 Basement Construction ...................................... 8 Floor Slab Design and Construction ............................. 8 Compliance ......................................... 8 PRELIMINARY GENERAL COMMENTS ................................ 8 Preliminary Geotechnical Engineering Exploration Terracon Merrick & Company TCW Project No. 20955191 Preliminary earthwork considerations are presented in the report. We appreciated being of service during the preliminary geotechnical engineering phase of this project, and are prepared to assist during the final geotechnical phase as well. If you have any questions concerning this report or any of our testing, inspection, design and consulting services, please do not hesitate to contact us. Sincerely, TERRACON CONSULTANTS WESTERN, INC.. L� Empire Division P"�r�SSa ' Prepared by: Senior Engineering Geologist Reviewed by: William J. Attw&rM P.E. ° Assistant Office Managee l-6,5O NRS/WJA/cic '� y.'°(°� 3ye- v ��OA Copies to: Addressee (2) Jim Sell Design (1) y Q1�F\GATE NU-(G.; 25-75 ;�•C'^,�' AIPG M• Irerracon CONSULTANTS WESTERN, INC. EMPIRE DIVISION P.O. Box 503 •301 N. Howes Fort Collins, Colorado 60522 (970) 484-0359 Fax (970) 484-0454 Larry G. O'Dell, P.E. Neil R. Sherrod, C.P.G. April 22, 1996 Merrick & Company 2450 South Peoria Street Aurora, Colorado 80014 Attn: Mr. Glen Tulk Re: Preliminary Geotechnical Engineering Report, The Pond at Hearthfire Douglas Road and County Road 13, Fort Collins, Colorado TCW Project No. 20955191 Terracon Consultants Western, Inc., Empire Division, has completed a preliminary geotechnical engineering exploration for the proposed Filing 1 of The Pond at Hearthfire to be located on Larimer County Road 13 south of Douglas Road, northeast of Richards Lake and northeast of Fort Collins, Colorado. The results of our engineering study, including the boring location diagram, laboratory test results, test boring records, and the preliminary geotechnical recommendations needed to aid in the preliminary design and construction of foundations and other earth connected phases of this project are attached. The subsurface soils at the site consist of sandy lean clays underlain by sandstone- claystone bedrock. The information obtained by the results of field exploration and laboratory testing completed for this study indicate the soils at the site exhibit moderate to. high swell potential and moderate to high bearing characteristics. The bedrock at the site exhibits high bearing characteristics and low swell potential. The soils at anticipated foundation bearing depths exhibit medium to stiff consistency, and the bedrock varies from medium hard to very hard to cemented and well cemented. Based on the preliminary geotechnical engineering analyses, subsurface exploration and laboratory test results, we recommend the proposed residences be supported on a conventional -type spread footing and grade beam and/or straight shaft pier foundation systems. Slab -on -grade may be utilized for the interior floor system provided that care is taken in the placement and compaction of the subgrade soil. If no movement can be tolerated, 'a structural floor system should be specified. Offices of The Terracon Companies, Inc. Geotechnical, Environmental and Materials Engineers Arizona ■ Arkansas ■ Colorado ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Minnesota Missouri ■ Montana ■ Nebraska ■ Nevada ■ Oklahoma -- ■ Texas ■ Utah ■ Wyoming QUALITY ENGINEERING SINCE 1966 PRELIMINARY GEOTECHNICAL ENGINEERING REPORT THE POND AT HEARTHFIRE DOUGLAS ROAD AND COUNTY ROAD 13 FORT COLLINS, COLORADO TCW PROJECT NO. 20955191 April 22, 1996 Prepared for MERRICK & COMPANY 2450 SOUTH PEORIA STREET AURORA,COLORADO 80014 ATTN: MR. GLEN TULK Prepared by. Terracon Consultants Western, Inc. Empire Division 301 North Howes Street Fort Collins, Colorado 80521 Empire Laboratories, Inc. A Division of The Terracon Companies, Inc. PRELIMINARY GEOTECHNICAL ENGINEERING REPORT THE POND AT HEARTHFIRE DOUGLAS ROAD AND COUNTY ROAD 13 FORT COLLINS, COLORADO TCW PROJECT NO. 20955191 April 22, 1996 Irerracon