HomeMy WebLinkAboutHEARTHFIRE (THE POND AT) SUBDIVISION - PRELIMINARY - 31-95B - CORRESPONDENCE - CITY STAFFZONING, ANNEXATION AND DEVELOPMENT OF LAND
dred (100) feet for the uses set forth in §
29-132(2), (3) and (5) above.
(3) Minimum depth of the front yard shall be
twenty (20) feet.
(4) Minimum depth of the rear yard shall be
fifteen (15) feet.
(5) For residential uses, the minimum side yard
width shall be fifteen (15) feet on the street
side of any corner lot and five (5) feet for all
interior side yards. For all other uses, the
minimum side yard width shall be the equiva.
lent of one (1) foot for each three (3) feet or
fraction thereof of building height, provided
that for school or church uses no side yard
shall be less than twenty-five (25) feet wide.
(Code 1972, § 11841(B) -.(F))
Sec. 29.134. Planned Unit Developments
Development of areas in the R-L District as a
Planned Unit Development plan as defined, pro-
cessed and approved according to § 29-526 may
vary the requirements of this Subdivision.
(Code 1972, § 118-41(G))
Secs. 29.135-29.145. Reserved.
Subdivision F. R-L P Low Density
Planned Residential District
Sec. 29-146. Purpose,
• The R-L-P Low Density Planned Residential Dis-
trict is for areas planned as a unit to provide
variation in use, density and building placement.
(Code 1972, § 118-41.1)
Sec. 29-147. Uses permitted.
The uses Permitted in the R-L-P District are as
follows:
(1) Any use permitted in the R-L Low Density
Residential District, subject to any use re-
quirement specified for the R-L District.
Any land use located on a Planned Unit
Development plan as defined. Processed and
approved according to § 29-526.
(Code 1972, § 118-41.1(A))
Supp. No. 19
1997
§ 29.163
Sec. 29.148. Bulk and area requirements.
The minimum area of lots, minimum width of
lots, minimum front yard, minimum rear yard
and minimum side yard requirements shall be
the same as specified for the R-L Low Density
Residential District.
(Code 1972, § 118-41.1(B))
Sec. 29-149. Planned Unit Developments.
Development of areas in the R-L-P District as a
Planned Unit Development plan as defined, pro-
ceased and approved according to § 29.526 may
vary the requirements of this Subdivision.
(Code 1972, § 118-41.1(C))
Secs. 29-150-29-160. Reserved.
Subdivision F.1. R.L.M Low Density
Multifamily District
Sec. 29.161. Purpose.
The R•L-M Low Density Multifamily District is
for areas containing low density multifamily uses.
(Code 1972, § 11842)
Sec. 29-162. Uses permitted.
The uses permitted in the R-L-M District are as
follows:
(1) Any use permitted in the R-L Low Density
Residential District, subject to all use re.
quirements specified for the R-L District.
(2) Two-family dwellings and multifamily dwell-
ings up to and including four -family units.
(3) Any land use located on a Planned Unit
Development plan as defined, Processed and
approved according to § 29-526.
(Code 1972, § 118.42(A))
Sec. 29-163. Bulk and area requirements.
The area requirements in the R-L-M District
are as follows:
(1) Minimum lot area shall be the equivalent
of three (3) times the total floor area of the
buildings, but not less than six thousand
(6,000) square feet for a single-family or
two-family dwelling and not less than nine
§ 29.118 FORT COLLINS CODE
(6) Any land use located on a Planned Unit
Development Plan as defined, processed and
approved according to § 29-256. .
(Ord. No. ill, 1991, § 1, 10.1-91; Ord. No. 68,
1992, § 1, 7-7-92)
Sec. 29.119. Bulk and area requirements.
(The bulk and area requirements in the N•C-L
District are as follows:]
(1) Mfnimuin lot area shall be equivalent to at
least three (3) times the floor area but not
less than six thousand (6,000) square feet.
(2) Minimum lot width shall be forty (40) feet.
(3) Minimum front yard depth shall be fifteen
(15) feet. Setbacks from garage doors to the
backs of public walks shall not be less than
twenty (20) feet.
(4) Minimum depth of rear yard shall be five
(5) feet to an existing alley or otherwise
fifteen (15) feet.
(5) Minimum side yard width shall be fifteen
(15) feet on the street side of any corner lot
and five (5) feet for all interior side yards.
(6) Maximum building height shall be thirty
(30) feet.
(Ord. No. 111, 1991, § 1, 10.1.91)
Sec. 29.120. Site plan requirements.
Permitted uses, listed in § 29.118(4) shall re-
quire that a site plan, landscape plan, .building
elevations and other supporting documentation
comply with § 29.526(g) shall be submitted to and
approved by the Planning and Zoning Board. Upon
receipt of a complete application, the Director of
Planning shall schedule the application for the
next Planning and Zoning Board hearing.
In conducting the review and making a decision
the Planning and Zoning Board shall determine
whether the proposed development conforms to §
29.526(d), Activity A, "All Development Criteria"
of the Code, the Design Standards for the neigh-
borhood planning area, and the standards for any
applicable historic district or structure. if the pro.
posed development conforms, it shall be approved;
if the proposed development does not conform, it
shall be denied.
(Ord. No. 111, 1991, § 1, 10-1.91; Ord. No. 68,
1992, § 2, 7.7-92)
Secs. 29.121-29-130. Reserved.
Subdiuision E. R-L Low Density
Residential District'
Sec. 29.131. Purpose.
The &L Low Density Residential District des.
ignation is for low density residential areas lo-
cated throughout the city.
(Code 1972,. § 118-41)
Sec. 29.132. Uses permitted.
The following uses are permitted in the R.I.
District:
(1) Single-family dwellings.
(2) Public and private schools for elementary
and high school education.
(3) Public and nonprofit quasi -public recreational
uses as a principal use.
(4) Essential public utility and public service
installations and facilities for the protec-
tion and welfare of the surrounding area,
provided that business offices and repair
and storage facilities are not included.
(5) Churches.
(6) Group homes, subject to approval by spe-
cial review.
(7) Accessory buildings and uses.
(8) Any land use located on a Planned Unit
Development plan as defined, processed and
approved according to § 29-526. .
(Code 1972, § 11841(A))
Sec. 29-133. Area requirements.
The area requirements in the R-L District are
as follows:
(1) Minimum lot area shall be the equivalent
of three (3) times the total floor area of the
building but not less than six thousand (6,000)
square feet.
(2) Minimum lot width shall be sixty (60) feet
for a single-family dwelling and one hun-
•Cross reference —Sign regulations, § 29.591 et seq.
Supp. No. 19 1 1996
From: Peter Eames
To: BBLANCHARD, SOLT
Date: 5/15/96 1:43pm
Subject: The Pond at Hearthfire
I'm sorry I won't be able to attend your neighborhood meeting tonight for The Pond at Hearthfire, but hopefully the
following will be helpful.
As a use -by -right single family subdivision in the RLP zone the process is fairly straightforward.
We review the plat prior to final to ensure that all of the lots conform to the minimum requirements of the zone. In
this case, each lot must be at least 6000 sq. ft., have 20' frontage on a public street, and be at least 60' wide at the
portion of the lot where the building will sit. If the proposed plat meets these requirements, then that part of the
zoning code is met.
Once the plat is approved and recorded, the contractor may begin submitting building permit applications. The first
review of the application that is done by the City is a zoning site plan review. Staff examines the site plan submitted
and the construction drawings to make sure that the required setbacks from property lines are met. In this zone, the
setbacks are 20' from the front property line, 15' from rear property line, 5' from interior side lot lines, and 15' from
the street side lot line on a comer lot. (It might not hurt to mention that these are the setbacks commonly used in
PUD's also, except that many PUD's only require a 10' rear setback). Staff also ensures that the building is not too
large for the lot. In the RLP zone, the lot has to be at least 3 times as large as the house. For instance, a 3000 sq.
ft. home needs a lot of at least 9000 sq. ft.
Once zoning has verified compliance with these regulations, a zoning release is given for the permit. This does not
mean that a permit can be issued yet. Many other depts. must also determine that their own requirements are met
before they can sign off on it. For example, Engineering must verify that certain public improvements are in, such as
curb and gutter, street, etc.. Only after all of the departments involved have signed off can a permit be issued. (This
is really no different than what happens with a PUD. The City has the same concerns regardless of what type of
approval process the development was subject to).
Some use -by -right subdivisions that are currently under construction or have recently been completed are:
Clarendon Hills
English Ranch
Coventry (US Homes)