Loading...
HomeMy WebLinkAboutEVERGREEN PARK, LOT 16, BLK. 4 (TRAFFIC MASTERS / VOGEL CONCRETE) - I-L SITE PLAN REVIEW - 38-95 - CORRESPONDENCE -l • " PROJECT ' City of Fort Collins COMMENT SHEET CurrentPlanning DATE: 21 August 1995 DEPARTMENT: PROJECT: 38-9S EVERGREEN PARK, Blk4, Lot 16 - IL Site Plan (Traffic Masters/Vogel Concrete) PLANNER: Mike Ludwig All comments must be received by: Friday, 1 September No Problems 'Problems or Concerns (see below) site plan • no comments utility plans - sheet 2 • indicate the widths of the drive on this sheet or on the detail • provide additional elevations in the driveway. detail only gives maxs and mins - how is it to be built? Date: /�/�� signature: -)=% i CHECK IF YOU WISH TO RECEIVE ❑ PLAT COPIES OF REVISIONS; ❑ SITE ❑ LANDSCAPE ❑ UTILITY COMMUNITY PLANNING and ENVIRONMENTAL. SERVICES... 281 NORTH COLLEGE, P.O.BOX 580 FORT COLLINS, COLORADO 80522-0580 (303)221-6750 CURRENT PLANNING DEPARTMENT Citv of Fort Collins PROJECT COMMENT SHEET DATE: 21 August 1995 DEPARTMENT: PROJECT: 38-95 EVERGREEN PARK, Blk4, Lot 16 - IL Site Plan (Traffic Masters/Vogel Concrete) PLANNER: Mike Ludwig All comments must be received by: Friday, 1 September No Problems ElProblems or Concerns (see below) comments: 1.) Please provide a copy of the drainage easement document for the detention pond. 2.) Please tie proposed and existing contours. 3.) Please show the existing contours on Blue Spruce Drive. 4.) Please show the 100-year HWL in, the gutter in the Section A -A detail on the Drainage Plan. 5.) Please provide the Q2 and Q100 values in the Drainage Summary on the Drainage Plan. 6.) Please include a vegetation/cover crop species table. Date: Signature: CHECK IF YOU WISH TO RECEIVE ❑ PLAT COPIES OF REVISIONS: ❑ SITE ❑ LANDSCAPE ❑ UTILITY COMMUNITY and ENVIRONMENTALAL SERVICES... 281 NORTH COLLEGE, P.O.BOX 580 FORT COLLINS, COLORADO 80522-0580 (303)221-6750 SER CURRENT PLANNING DEPARTMENT shall not be planted closer than four feet to any water or sewer line or service. Tree planting shall be coordinated with Public Service Company. Locations of all utilities shall be verified in the field prior to planting." This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Upon receipt and review of the requested revisions, staff will schedule an administrative hearing for the proposed I-L Site Plan. Please contact me at 221-6206 if you have any questions or concerns related to these comments. I would like to schedule a meeting with you as soon as possible, if necessary, to discuss these comments. Sincerely, Michael Ludwig Project Planner xc: Kerrie Ashbeck Stormwater Utility file/Project Planner f n in a wheelchair and must be connected to the public way (public sidewalk) by an "accessible route of travel" complying with the American National Standards Institute publication Accessible and Usable Buildings and Facilities. Running slopes on accessible routes shall not exceed 1:20 with cross slopes not exceeding 1:48. Accessible parking and access aisles shall comply with the above referenced standards with slopes not exceeding 1:48 in any direction. Please show a connection to the public sidewalk for all exits/entries. .K. Storage or use of hazardous materials must be in compliance with the Fire Code and Chapter 9 of the 1991 Uniform Building Code as adopted by the City of Fort Collins. A list of such materials with quantities and classifications should be submitted for review at the time of building permit application. Exterior walls, openings in exterior walls and projections from exterior walls (cornices, eave overhangs, etc.) shall be of fire resistive construction if located less than 10 feet from a property line. The storage buildings must be located 10 feet from the property lines or be of fire -resistive construction. 4. Attached are comments from the Engineering Department. 5. Attached are comments from the Stormwater Utility Department. 6. The Planning Department offers the following comments: ✓a. Additional plantings (shrubs, etc.) are needed beneath the trees along the Blue Spruce frontage. . The slatted, chain link fence should also be installed along the eastern boundary of the gravel road base (western edge of the paved surface). ✓c. Foundation plantings are needed on the east side of the warehouse building. Vd• Please add "MA" to the plant list. Cc'wnj +o GvAcmasler Please add -an "overhead door" (?) note to the site plan at the southwest corner of the building. Please add notes to the building elevations which describe th colo and materials of the proposed buildings. Staff suggests adding a brick or conc a block foundation to the building. Please add overall dimensions to the building elevations The Water and Wastewater Utility requests that the following landscape note be added to the Site/Landscape Plan: "Trees shall not be planted closer than four feet to any gas or electric line and no, closer than 10 feet to any water or sewer line or service. Shrubs Community . ,anning and Environmental Serx :s Current Planning 0 September 15, 1995 Dick Wartenbe and Dan Vogel c/o Phil Robinson Stewart and Associates P. O. Box 429 Fort Collins, CO 80522 Dear Phil, Staff has reviewed your documents for the Evergreen Park, Block 4, Lot 16, I-L Site Plan, that were submitted on August 18, 1995, and would like to offer the following comments: The Poudre Fire Authority states that the warehouse building shown exceeds the 5,000 square feet containment area and will need to be provided with an approved fire suppression system or fire contained to less than 5,000 square feet sections. 2. The Zoning Department offers the following comments: 4. An additional street tree is needed along the Blue Spruce Drive frontage. Trees must be planted every 50' along the north and south property lines from Blue Spruce Drive back to the western edge of the asphalt paving. /c. No storage or parking of vehicles will be allowed on the gravel road base area. If storage or parking of vehicles is proposed, the area must be paved and landscaped. ✓d. Please show bike rack locations on the Site/Landscape Plan. 4 Please show the location of any trash dumpsters. Dumpsters must be fully enclosed. 3. The Building Inspections Department offers the following comments: The site shall be accessible to persons with disabilities in accordance with Uniform Building Code Section 3103 and UBC Appendix Section 3106. Provide designated and marked accessible routes between the building and the public way and accessible parking and buildings. Provide parking and signs per Appendix Section 3107. The office use is required by Section 3103 Uniform Building Code to be handicapped accessible. All required exits and all building entrances located within six inches of grade (in the portion of the building used for offices) must be accessible to a person 281 North College Avenue • P.O. Box 580 Fort Collins, CO 80522-0580 • (970) 221-6750 FAX (970) 221-6378 TDD (970) 224-6002