HomeMy WebLinkAboutEVERGREEN BUSINESS PARK, LOTS 5 & 6, BLOCK 5 - I-L SITE PLAN REVIEW - 45-95 - CORRESPONDENCE -g. The Site Plan shows a note which states "Edge of Phase 2 asphalt/landscape mulch bed typ." However, the Landscape plan has a note which designates the limit of landscaping as the edge of Phase 1. All landscaping for Phases 1 and 2 should be shown on the Landscape Plan and notes coordinated. Please indicate the total square footage of each of the proposed buildings within the footprint of each building. Please provide typical dimensions for the standard and handicap parking spaces. Z�19 Staff suggests that sidewalks along the north property line of lot 5 and south property line of lot 6 be added to allow pedestrian connections from the proposed buildings to 1jjr the public sidewalk along Blue Spruce Drive. This may require four parking spaces to be deleted. Office facilities require safe and handicap accessible routes to the building entrances It appears that each of the "bays" are designed to be an office/warehouse. Access to the building entrances is gained via automobile travel lanes and/or through travel/parking areas for vehicles accessing the proposed overhead doors to the buildings. Staff suggests that the buildings be shifted towards the center of the site to allow for pedestrian access to entrances on the north side of the warehouse/office building on Lot 5 and to the south side of the warehouseloffice building on Lot 6. If pedestrian entrances are provided as described in comment & staff suggests that the windows and glass doors be moved to the north side of the warehouse/office building on Lot 5 and to the north side of the warehouse/office building on Lot 6. apt/ Please indicate the color(s) of the proposed buildings on the elevations. This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Once the above stated comments have been addressed, Staff will schedule an Administrative Hearing with the Director of Planning for this I-L Site Plan. Please contact me at 221-6206 if you have any questions or concerns related to these comments. I would like to schedule a meeting with you as soon as possible, if necessary, to discuss these comments. Sinceerrely/ Michael Ludwig Project Planner xc: Sheri Wamhoff Stormwater Utility file/Project Planner 6. The Water Conservation Specialist offers the following comments: The Landscape Plan shall contain a note calling for the review and approval by the City of Fort Collins of the required landscape irrigation system, prior to the issuance / of a building permit. The landscape plan shall include the total area (in square feet) for each landscape category. Landscape categories are distinguished by their water requirements and intended maintenance level. Examples of possible categories include, but are not limited to, high water turfgrass, low water turfgrass, low water planting beds, moderate water planting beds, and non -plant areas (paved areas, etc.). Please refer to page 4 of the attached Water Conservation Standards for Landscaping for further guidance. 0 Attached is a copy of the comments received from the Engineering Department. 8. Attached is a copy of the comments received from the Stormwater Utility. 9. The/Planning Department offers the following comments. g( Please add a scale for the Vicinity Map. Please revise General Note 1 on the Site Plan to state: "Existing zoning is I-L, Limited Industrial." Please revise General Note 2 on the Site Plan to state: "See Landscape Plan (Sheet 2 of 3) for all landscape requirements." Please revise the Planning certification block to state: Approved: By the Director of Planning of the City of Fort Collins, Colorado, this day of ,19 . Director of Planning Please number the Site Plan as "Sheet 1 of 3", the Landscape Plan as "Sheet 2 of 3", and the Building Elevations as "Sheet 3 of 3". Please clearly delineate the phasing line which separates Phases 1 and 2 and label Phases 1 and 2. If the applicant chooses to pave the turnaround with Phase 1, appropriate landscaping must be installed. Please show the location of trash dumpsters on the site plan. All dumpsters must be fully enclosed (not visible), gated, and located on a paved surface. c� A bike rack is needed for each of the warehouse/office buildings. A 5' landscaping strip is required along all parking/lot lines under the Phase 2 parking extension. e/ A 2" caliper deciduous trees are needed on the north and south sides of the parking lot along the property lines. A 5' landscaping strip is required along the north and south property lines. It is currently only 2' or 3' at the "back-up" sections of the parking lot. City Code requires parking lots to have 6% interior landscaping. At the present time, this proposal only provides 440 square feet of interior landscaping. A total of 1,346 square feet of interior landscaping is needed. Interior landscaping does not include the five foot landscape strip along the property lines nor the ten foot landscape strip between the parking lot and Blue Spruce Drive. The Poudre Fire Authority stated that the office/warehouse buildings on lots 5 and 6 exceed the 150' access requirement by approximately 20'. The applicant must either provide an additional fire lane access back to Blue Spruce Drive, access to adjacent properties, or fire sprinkler both of the buildings. 5� The Water and Wastewater Utility offers the following comments: Please show the existing water and sanitary sewer mains in Blue Spruce Drive on the Site Plan. Please show the water and sewer services to the proposed buildings and identify the proposed location for the curb stops and meter pits on the Site Plan. Please add standard details for the water and sanitary sewer services, meter settings/pits, etc. to the Site Plan. 7 A 4 foot separation distance for shrubs and a 10 foot separation distance for trees must be maintained from all water and sanitary sewer services. Please coordinate the location of all landscaping and services with the site engineer/designer. Commt y Planning and Environmental vices Current Planning City of Fort Collins November 3, 1995 Greg D. Fisher, Architect 3115 Clyde Street Fort Collins, CO 80524 Dear Greg, Staff has reviewed your documents for the Evergreen Park, Block 5, Lots 5 and 6, I-VAid Plan that were submitted on October 6, 1995, and would like to offer the following comments The Light and Power Utility states that street trees must be a minimum of 40 feet from street lights. The Building Inspections Department offers the following comments: The site shall be accessible to persons with disabilities in accordance with Uniform Building Code Section 3103 and UBC Appendix Section 3106. Provide designated and marked accessible routes between building and the public way and accessible parking and buildings. Provide parking and signs per Appendix Section 3107. All required exits and all building entrances located within six inches of grade must be accessible to a person in a wheelchair and must be connected to the public way (public sidewalk) by an "accessible route of travel' complying with the American National Standards Institute publication Accessible and Usable Buildings and Facilities. Running slopes on accessible routes shall not exceed 1:20 with cross slopes not exceeding 1:48. Accessible parking and access aisles shall comply with the above referenced standards with slopes not exceeding 1:48 in any direction. Please show ,connections to the public sidewalk for all entrances and exits. Oe The proposed warehouse/office buildings exceed 5,000 square feet in size and therefore must be equipped with an automatic fire suppression system or compartmentalized in sections of less than 5,000 square feet by fire resistive construction in accordance with Sections 3802, UBC as amended by the City of Fort Collins. Please add a General Note to the Site Plan regarding this requirement. 3. The Zoning Department offers the following comments: ,A! A barrier (i.e. fence) which prohibits access by vehicles other than emergency vehicles, must be installed at the edge of the asphalt paving and the temporary gravel turnaround. This fence can be removed once the turnaround is paved with Phase 2. 281 North College Avenue • P.O. Box 580 Fort Collins, CO 80522-0580 • (970) 221-6750 FAX (970) 221-6378 TDD (970) 224-6002