HomeMy WebLinkAboutFOSSIL CREEK NURSERY PUD - PRELIMINARY - 40-95 - SUBMITTAL DOCUMENTS - ROUND 1 - LDGS ACTIVITY FORM1 23. Ice or low temperature water storage system utilized for off-peak air conditioning and reduced air conditioning equipment sizes 24. Electric resistance heat not used 25. Night air used for pre -cooling space with building air handling system, automatically controlled 26. Fluorescent lamps and electronic ballasts are used throughout the building 27. Motion detector lighting control is used for all lighting 28. Lighting watt density less than 2W/sq. ft. 29. Building uses active solar, geothermal, wind, or other non -depleting energy source (capable of collecting, storing, and distributing) for space heating, with a minimum savings fraction of 0.4 30. Radiant heating used in lieu of unit heaters 31. Roof automatically cooled with water spray 32. Windows are shaded from summer sun (over- hangs, window coverings, deciduous trees) 33. Computerized energy management system used with capability to cycle equipment, automatic lights on/off, optimum start, night/weekend setback 34. Use of an existing structure that is in compliance or is brought into compliance with the adopted Model Energy Code (entire structure must be in compliance) 35. Other rncthods (to accommodate new technology). to 1.0 0.2 0.1 9 0.2 0.3 3.0 0.2 0.1 0.2 LO 1.0 Points will be assigned on a proportionate basis by comparing the amount of energy that can be saved by the proposed measure with the amount of energy that can be saved by utilizing other items from the Method Two listing. Land Development Guidance system for Planned Unit Developments The City of Fort Collins, Colorado, Revised March 1994 - 122 - 4. Passive solar heating utilized by building healing system with a minimum of savings fraction of 0.4 (using orientation that maximizes solar gain and window coverings) 3.0 5. Natural daylighting utilized, with automatic insulated covers with minimum R-value of 2.5 0.3 6. Overall wall U-value is <0.2 1.0 7. Overall roof U-value is <0.6 0.3 8. Reflective glass or film used on all windows 0.2 9. Vestibules, air locks, or revolving doors used on all entrances 0.2 10. Automatic night/weekend temperature setback is provided 0.4 11. "Free Cooling" (using outside air) used for fan systems of less than 5000 CFM 0.2 12. Low leakage outside air and exhaust air dampers used; 1 %, leakage maximum at 5" W.C. 0.3 13. Variable air volume system used, with inlet vanes or variable speed drives 0.5 14. High efficiency motors (as labeled by manufacturer) used 0.1 15. Water-cooled condensers used for mechanical cooling systems 0.2 16. Evaporative cooling used in lieu of mechanical cooling 0.4 17. Boilers or furnaces used with firing efficiencies greater than 82% 0.2 18. Automatic spark ignition used for gas fired boilers, furnaces, unit heaters, etc. 0.1 19. Automatic dampers used in combustion air intakes 0.1 20. Outside air reset used for boiler supply water temperature control (boiler water temp reset inversely from outside temp) 0.3 21. Exhaust or condenser heal recovery utilized 0.3 22. Waste water heat recovery utilized (car washes, laundries, etc.) 2.0 Land Development Guidance System for Planned Unit Developments The City of Fort Collins, Colorado, Revised March 1994 - 121 - • APPENDIX "E" Energy Conservation Methods Method One: Direct comparison to Model Energy Code. This method awards points based on tie extent to which the proposed building exceeds the minimum standard as established in the Model Energy Code using the systems approach. Certification by a professional engineer licensed in Colorado will be required to demonstrate that the annual energy consumption will be a certain percentage, less than the same building just meeting die minimum standard as defined in the Model Energy Code. Percentage below the Model Energy Code Minimum Points Awarded 15 - 25% 1.0 point 26-35% 2.0 points 36 - 45% 3.0 points 46% or more 4.0 points Method Two: Points will be given for the implementation of one or more of tic energy conservation measures listed below. The use of Method Two requires that die final approved PUD plans and construction plans submitted for a Building Permit must specify all of die energy conservation measures for which points have been awarded in the approved plan. The total number of energy conservation points earned will be based upon die following table: 0.6 - 1.5 LO point 1.6 - 2.5 2.0 points 2.6 - 3.5 3.0 points 3.6 or more 4.0 points Method Two Energy Conservation Measures: 1. Long axis of building is cast/west (building oriented to south, with majority of windows on south wall) 0.2 2. Ratio of exterior wall area to interior Iloor area is less than 1.5 0.3 3. Mass of exterior building walls greater than 30 lb/sq. ft. 0.2 Land Development Guidance System for Planned Unit Developments The City of Port Collins, Colorado, Revised March 1994 - 120 - Activity A: ALL DEVELOPMENT CRITERIA ALL CRITERIA APPLICABLE CRITERIA ONLY CRI T =RION Is the c:ne'on a cFlicacle7 WW the cneno be salis(ea7 Yes No If no, please exclain 3 A1. COMti1UNliY-IVIDE CRITERIA. 1.1 Solar Orientation I I I I I I 1.2 ComArehensive Plan I I I I x i 1.31 Wildlife Habitat I I 1 1 1.4 Mineral Deocsit I I ( II 1 .5,=*=;Iocically Sersitive Ares I reserved I I I I I I 1— Lands-cr Acricultural Imoor,ancs I r? ?r.•ed 1.7 Enerev Conservation I I I' I I 1.8 Air Qualitv I I I I I I 1.9 Water Qualitv I I I I I I 10 Sawace and W_sies I I I I 1 11 WaterComervat4onIx 1 I 1.12 Residential Density I I 1A I 1 A. 2. NE!GHEOR.HOOD COMP.�-'TICILIT,r CRITE-R1A 2.1 Venicuiar. P=desman. Bike Transooriion IX I I I x I I 2 2 °uilcinc P!acement and Orientation 1XI I IX I I 2= Natural r"e_iures I I I I I I 2 4 Venicular Circulation anc Parkinc I ! I I I 2.� emergency Access r-ecestrlan Clrc--la[lon ix I 1 I I I 2.7=,rcnitec:ure I I I I I I 2.8Euilding !-ieic_ni and Views I I I I I I 2.S : Shading I I I 2.10 Solar Access IXI I I I 2.11 Historic Resources I I I 2.12 Setbacks 4I X 2.13 Landscape I I I k l 2.144 Signs I I I YCI I 2.13- Site Lighting I I 2.16 Ncise and Vibration I I I I 2.17 Glare or Heat I 2.18 Hazardous Materials I A 3. ENGINEERING CRITERIA 3.1 Utility Capacity 3.2 Design Standards I 3.3 Water Hazards x 3.4 Geologic Hazards I - Land Development Guidance System for Planned Unit Developments The Ciry of Fort Collins, Colorado. Revised h [994 U S� -61- P