23. Ice or low temperature water storage system
utilized for off-peak air conditioning and
reduced air conditioning equipment sizes
24. Electric resistance heat not used
25. Night air used for pre -cooling space with
building air handling system, automatically
controlled
26. Fluorescent lamps and electronic ballasts are
used throughout the building
27. Motion detector lighting control is used for
all lighting
28. Lighting watt density less than 2W/sq. ft.
29. Building uses active solar, geothermal, wind,
or other non -depleting energy source (capable
of collecting, storing, and distributing) for
space heating, with a minimum savings fraction
of 0.4
30. Radiant heating used in lieu of unit heaters
31. Roof automatically cooled with water spray
32. Windows are shaded from summer sun (over-
hangs, window coverings, deciduous trees)
33. Computerized energy management system
used with capability to cycle equipment,
automatic lights on/off, optimum start,
night/weekend setback
34. Use of an existing structure that is in
compliance or is brought into compliance
with the adopted Model Energy Code
(entire structure must be in compliance)
35. Other rncthods (to accommodate new
technology).
to
1.0
0.2
0.1
9
0.2
0.3
3.0
0.2
0.1
0.2
LO
1.0
Points will be assigned on a
proportionate basis by
comparing the amount of energy
that can be saved by the
proposed measure with the
amount of energy that can be
saved by utilizing other items
from the Method Two listing.
Land Development Guidance system for Planned Unit Developments
The City of Fort Collins, Colorado, Revised March 1994
- 122 -
4.
Passive solar heating utilized by building
healing system with a minimum of savings
fraction of 0.4 (using orientation that
maximizes solar gain and window coverings)
3.0
5.
Natural daylighting utilized, with automatic
insulated covers with minimum R-value of 2.5
0.3
6.
Overall wall U-value is <0.2
1.0
7.
Overall roof U-value is <0.6
0.3
8.
Reflective glass or film used on all windows
0.2
9.
Vestibules, air locks, or revolving doors used
on all entrances
0.2
10.
Automatic night/weekend temperature
setback is provided
0.4
11.
"Free Cooling" (using outside air) used for fan
systems of less than 5000 CFM
0.2
12.
Low leakage outside air and exhaust air
dampers used; 1 %, leakage maximum at 5" W.C.
0.3
13.
Variable air volume system used, with inlet
vanes or variable speed drives
0.5
14.
High efficiency motors (as labeled by
manufacturer) used
0.1
15.
Water-cooled condensers used for
mechanical cooling systems
0.2
16.
Evaporative cooling used in lieu of
mechanical cooling
0.4
17.
Boilers or furnaces used with firing
efficiencies greater than 82%
0.2
18.
Automatic spark ignition used for gas
fired boilers, furnaces, unit heaters, etc.
0.1
19.
Automatic dampers used in combustion
air intakes
0.1
20.
Outside air reset used for boiler supply
water temperature control (boiler water
temp reset inversely from outside temp)
0.3
21.
Exhaust or condenser heal recovery utilized
0.3
22.
Waste water heat recovery utilized (car
washes, laundries, etc.)
2.0
Land Development Guidance System for Planned Unit Developments
The City of Fort Collins, Colorado, Revised March 1994
- 121 -
•
APPENDIX "E"
Energy Conservation Methods
Method One: Direct comparison to Model Energy Code.
This method awards points based on tie extent to which the proposed building exceeds the minimum
standard as established in the Model Energy Code using the systems approach. Certification by a
professional engineer licensed in Colorado will be required to demonstrate that the annual energy
consumption will be a certain percentage, less than the same building just meeting die minimum
standard as defined in the Model Energy Code.
Percentage below the
Model Energy Code Minimum Points Awarded
15 - 25% 1.0 point
26-35% 2.0 points
36 - 45% 3.0 points
46% or more 4.0 points
Method Two:
Points will be given for the implementation of one or more of tic energy conservation measures
listed below. The use of Method Two requires that die final approved PUD plans and construction
plans submitted for a Building Permit must specify all of die energy conservation measures for
which points have been awarded in the approved plan. The total number of energy conservation
points earned will be based upon die following table:
0.6 - 1.5
LO point
1.6 - 2.5
2.0 points
2.6 - 3.5
3.0 points
3.6 or more
4.0 points
Method Two Energy Conservation Measures:
1. Long axis of building is cast/west (building
oriented to south, with majority of windows
on south wall) 0.2
2. Ratio of exterior wall area to interior Iloor
area is less than 1.5 0.3
3. Mass of exterior building walls greater than
30 lb/sq. ft. 0.2
Land Development Guidance System for Planned Unit Developments
The City of Port Collins, Colorado, Revised March 1994
- 120 -
Activity A: ALL DEVELOPMENT CRITERIA
ALL CRITERIA
APPLICABLE CRITERIA ONLY
CRI T =RION
Is the c:ne'on
a cFlicacle7
WW the cneno
be salis(ea7
Yes No If no, please exclain
3
A1. COMti1UNliY-IVIDE CRITERIA.
1.1 Solar Orientation I I I
I I I
1.2 ComArehensive Plan I I I
I x i
1.31 Wildlife Habitat I
I 1 1
1.4 Mineral Deocsit I I
( II
1 .5,=*=;Iocically Sersitive Ares I reserved
I I I
I I I
1— Lands-cr Acricultural Imoor,ancs I r? ?r.•ed
1.7 Enerev Conservation I I I' I I
1.8 Air Qualitv I I I I I I
1.9 Water Qualitv I I I I I I
10 Sawace and W_sies
I I I I
1 11 WaterComervat4onIx
1 I
1.12 Residential Density I I 1A I 1
A. 2. NE!GHEOR.HOOD COMP.�-'TICILIT,r CRITE-R1A
2.1 Venicuiar. P=desman. Bike Transooriion IX I I
I x I I
2 2 °uilcinc P!acement and Orientation
1XI I
IX I I
2= Natural r"e_iures I I I
I I I
2 4 Venicular Circulation anc Parkinc I !
I I
I
2.� emergency Access
r-ecestrlan Clrc--la[lon
ix I 1 I
I
I
2.7=,rcnitec:ure I I I I
I
I
2.8Euilding !-ieic_ni and Views I
I I I
I
I
2.S : Shading
I I
I
2.10 Solar Access IXI
I I
I
2.11 Historic Resources I
I
I
2.12 Setbacks
4I X
2.13 Landscape
I I I
k l
2.144 Signs
I I I
YCI
I
2.13- Site Lighting
I I
2.16 Ncise and Vibration
I I I
I
2.17 Glare or Heat
I
2.18 Hazardous Materials
I
A 3. ENGINEERING CRITERIA
3.1 Utility Capacity
3.2 Design Standards
I
3.3 Water Hazards
x
3.4 Geologic Hazards
I
-
Land Development Guidance System for Planned Unit Developments
The Ciry of Fort Collins, Colorado. Revised h [994
U S�
-61-
P