HomeMy WebLinkAboutESKIN PUD - PRELIMINARY - 48-95 - CORRESPONDENCE -e. Please provide the following additional "Project Information' for existing conditions, proposed Alternative A, and proposed Alternative B: (1) The number bedrooms. (2) The residential density. (3) The total floor area and ratio of floor area to lot size with a breakdown by land use. (4) The proposed coverage of buildings and structures including the following: (a) Percentage and square footage of building coverage. (b) Percentage and square footage of driveways and parking. (c) Percentage and square footage of landscaped area. (5) The number of off-street parking spaces including standard, handicapped, bicycle, and motorcycle parking. f. The Site and Landscape Plan currently states that all landscaping is existing and that no additional landscaping is proposed. However, the applicant is proposing to increase parking areas. The perimeter of all parking areas must be screened and 6% interior parking lot landscaping must be provided. Please clearly designate existing and proposed landscaping. This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please be aware of the following dates and deadlines to assure your ability to stay on schedule for the December 18, 1995 Planning and Zoning Board hearing: ****************************************************************************** Plan revisions are due by 5:00 p.m. on November 29, 1995. Please contact me for the number of folded revisions required for each document. PMI's, renderings, and 8 folded copies of final revisions are due by 3:00 p.m. on December 11, 1995. ****************************************************************************** Please contact me at 221-6206 if you have any questions or concerns related to these comments. I would like to schedule a meeting with you as soon as possible, if necessary, to discuss these comments. Sincerely, Michael Ludwig Project Planner xc: Kerrie Ashbeck Stormwater Utility file/Project Planner Site Plan. U S WEST states that the owner is responsible for all telephone wiring beyond the main j terminal in the building. 4! 1 The Engineering Department states that the Final P.U.D. submittal must include all utility, grading and drainage information. The Water and Wastewater Utility stated that there may be a conflict between an existing fire hydrant at the corner of Drake and Harvard and the proposed parking. 6. Th lnternative the following comments: hieves more than 50% of the maximum applicable points on the Uses Point Chart and is "essentially the same as what already exists." Theination of a 2,015 square foot medical office and 3 bedroom apartment (as per Linda Ripley on 11/l/95) generates an off-street parking need of 11 spaces. Based upon the Zoning Department's comments, it appears that 11 off-street parking spaces can be provided. Alternative B would allow Dr. Eskin to change his place of residence and keep his chiropractic office at its current location as described in the Planning Objectives which were submitted. Alternative A does not achieve at least 50% of the maximum applicable points on the Business Service Uses Point Chart. The combination of a 2,015 square feet of medical office use and 2,351 square feet of general office use generates an off-street parking need of 16 parking spaces. Based upon the comments expressed by the Zoning Department and constraints of the site, it does not appear that the proposed site can provide 16 off-street parking spaces and would therefore fail to meet All - Development Criteria A-2.4, Vehicular Circulation and Parking. Staff does not feel that variances to these requirements are justified on the basis that Alternative A, as currently proposed, is detrimental to the public good and that Alternative A is not equal to or better than Alternative B. Please list the specific energy conservation measures which will be incorporated with this P.U.D. by Energy Conservation Method 2 on the Preliminary Site/Landscape Plan. A joint access agreement with the State Farm Insurance Office must be obtained for the rear parking lot. Please submit this agreement by the November 29, 1995 plan revision deadline. he Site Plan should show all surrounding land uses, structures, fire hydrants, transformers, public right of way, etc. within 150' of the property boundaries. j Commi ty Planning and Environmental - ,rvices Current Planning City of Fort Collins November 1, 1995 Linda Ripley and Associates 223 Jefferson Street Fort Collins, CO 80524 Dear Linda, Staff has reviewed your documents for the Eskin P.U.D., Preliminary, #48-95, that were submitted on October 16, 1995, and would like to offer the following comments: The Building Inspections Department stated that Alternative uses A or B will cause the building to no longer be classified as a Home Occupation. All provisions of the building code must be met for the existing and proposed uses. Typically, this means providing access for the disabled, supplying fire -resistive separations between different uses, providing toilet facilities for customers and employees that are handicapped accessible. The change of use requires a revised "certificate of occupancy" obtained through a building permit process after a P.U.D. is approved. 2. The Zoning Department offers the following comments: a/ M It appears that the Eskin P.U.D. shares a drive with the State Farm Insurance office for the rear parking lot. Please show the location of the entire shared drive. There is a vehicle backing conflict in the rear parking lot. It appears that the two southern most parking spaces will have to be moved or deleted. A landscape strip with an average width of 10' (minimum width of 5' at any single point) is needed from the back of the sidewalk along Harvard to the first parking stalls. It appears that the two parking spaces immediately adjacent to the sidewalk must be deleted. There is a vehicle backing conflict in the front parking lot. It appears that the two spaces below the second story overhang should be deleted. A dumostet enclohes ekan bike rac must be added to the Site Plan. Building dimensions and the distance of the building to lot lines must be added to the 281 North College Avenue • P.O. Box 580 Fort Collins, CO 80522-0580 • (970) 221-6750 FAX (970) 221-6378 TDD (970) 224-6002