HomeMy WebLinkAboutHARMONY RIDGE PUD, PHASE 2 (2ND FILING) - PRELIMINARY / FINAL - 49-95D - CORRESPONDENCE - VARIANCE REQUEST (3)March 20, 2001
Mr. Mike Virata .
City Of Fort Collins
Engineering Department
281 N. College Avenue
Fort Collins, CO 80524
Re: Harmony Ridge P.U.D. SECOND FILING
Project NO. 0927-010
Dear Mike:
This letter is in response to staff comments of January 19, 2001 regarding the above -
reference project.
Also, this letter is for the purposes of requesting a variance to City Standard 1.02.03.04
— a minimum approach grade of 2% to be provided at the intersection of local streets.
This variance is for the following Intersections:
1. Approach grades on Prairie Ridge Ct. at the intersection of Prairie Ridge Dr. We
are requesting a variance to City Standard 1,02.03.05(c). After discussion
between Mike Jacobson and you, it was determined that the best alternative for
this Intersection was to hold the "K" value and let the approach grade vary. The
approach grade on the west flow line has been designed to a 4% grade and the
east flow line is a 3.09% approach grade. While both of these grades do exceed
the existing standard they still are in compliance with the new guidelines as
adopted by the City of Fort Collins.
Should you have further questions or comments, please do not hesitate to contact me.
Sincerely,
TST, INC. CONSULTING ENGINEERS
ichard A. Dvorak
RADIamb
TST, INC, 748Whalers Way - Building D
Consulting Engineers Fort Collins, CO 80525
(970) 226-0557
Metro (303) 595-9103
Fax (970) 226-0204
Email Info®tsdnc.com