HomeMy WebLinkAboutJEFFERSON COMMONS PUD - PRELIMINARY - 50-95 - CORRESPONDENCE - REVISIONS (3)Please contact me at 221-6206 if you have any questions or concerns related to these comments. I
would like to schedule a meeting with you as soon as possible, if necessary, to discuss these
comments.
Sincerely,
Michael Ludwig
Project Planner
xc: Kerrie Ashbeck
Stocmwater Utility
file/Project Planner
h. The Site Plan shows only five trash enclosures for 204 units. More enclosures are
needed and should incorporate recycling bins.
i. Please add a note to the Landscape Plan which stateLJ"The developer shall ensure
that the landscape plan is coordinated with the plans done by other consultants so that
the proposed grading, storm drainage, or other construction does not conflict no
preclude installation and maintenance of landscape elements on this plan."
j. General note 14 on the Site Plan is not relevant and can be deleted.
k; 4 bedroom apartments (potentially 4 unrelated individuals per dwelling unit) are not
allowed through the variance process. Pursuant to Section 29-526 (E6) of the City
Code, "All residential developments approved pursuant to this section shall conform
to the definition of "family" as established in Section 20-1 of the code, provided,
however, that with respect to multiple -family dwellings only, the Planning and Zoning
Board may, upon receipt of written request by the developer and upon a finding that
all applicable criteria of this section have been satisfied, increase the number of
unrelated persons who may reside in individual dwelling units. Further, the Planning
and Zoning Board shall not increase said number unless it is satisfied that the
developer has provided additional open space, recreational areas, parking areas, and
public facilities as are necessary to adequately serve the occupants of the development
and to protect the adjacent neighborhood." Please submit a request and justification
for such an increase at the Jefferson Commons PUD.
This completes the review comments at this time. Additional comments may be forthcoming as the
various departments and reviewing agencies continue to review this request. Please be aware of the
following dates and deadlines to assure your ability to stay on schedule for the January 26, 1996
Planning and Zoning
Board hearing:
**************R****RRR******R*RRR*******RRRR**********RRRR******R****RRR*RRRRRR
Plan revisions are due by 5:00 p.m. on January 3, 1996. Please contact me for the number of
folded revisions required for each document.
PMT's, renderings, and 8 folded copies of final revisions are due by 3:00 p.m. on January 16,
1996.
****R******RRRRRRRRR******RRR****RRRRRR**RRRRRR*****R*RRR**********************
A-2.2 Building Placement and Orientation. It does not appear the proposed Site
Plan has any relationship to neighborhood character. It does a marginal job of
forming the "activity area". The basketball, and tennis courts appear to be stuck in
the corner of the development where they will get very little use. Why not
incorporate them in the middle of the development? Will this area be lighted? What
about noise and light pollution on surrounding neighbors to the north and east?
The ratio of the building heights to the width of the open space is should be
reconsidered. It appears that open space was an after thought and that it is only the
remainder of land after buildings and parking were placed on plan.
A-2.4 Vehicular Circulation and Parking asks: "Is the street and parking system
designed to be safe, efficient, convenient and attractive, considering use by all modes
of transportation that will use the system, (including, without limitation, cars, trucks,
buses, bicycles and emergency vehicles)? The proposed "secured" or "gated"
community does not meet this criteria. The circulation through the parking lot is not
efficient or convenient. The parking lot is over -parked by approximately 200 spaces
and does not contribute to the developments attractiveness. The formation of
useable or purposefiil spaces is marginal. Rather, parking is everywhere and useable
spaces are "left over" and not distributed proportionately.
A-2.6 Pedestrian Circulation asks: "Does the pedestrian circulation system (a)
accommodate pedestrian movement from the neighborhood to the site and throughout
the proposed development safely and conveniently and (b) contribute to the
attractiveness of the development?" The "secured" or "gated" community prevents
pedestrian movement from the neighborhood to and throughout the site. The
proposed layout is not efficient, convenient, or attractive. The entire development is
auto -oriented, not pedestrian -oriented or equal.
A-2.7 Architecture. Buildings should be of a similar size to o err bu- ildings in the
neighborhood. It does not appear that height is the issue. It is the placement and
mass of the buildings. Staff suggests smaller buildings towards the single family side
of the development and the larger buildings near the commercial uses and existing
multi -family buildings east of this proposal. The mass and scale of the proposed
buildings must be mitigated. Brick on the first floor and heavy dimensional, high -
profile shingles are a starting point.
A-2.8 Building Height and Views. Staff does not see the height of buildings as an
issue (see A-2.7). However, the applicant must submit a request and justification for
a variance to exceed 40'. Please refer to Section 29-526 (K) of the City Code (page
108 of the LDGS) for an explanation of the variance procedures.
A-2.12 Setbacks. Staff is especially concerned about the placement of building 4 in
relation to the single family residences. This building is 47' tall and a portion of is not
more than 10' from the property line.
'Ird. In order to claim 5 points for Criterion "m" of the Residential Uses point chart, there
must be at least 1.586 acres (69,086.16 square feet) of recreational space.
"Recreational space shall mean privately owned space which is designed for active
recreational use for more than three (3) families and would qualify as one (1) of the
following categories:
(1) Active open space.
[a] A parcel of not less than ten thousand (10,000) square feet and not
less than fifty (50) linear feet in the smallest dimensions;
[b] Public dedications may not contribute to the active open space area;
[c] Partial credit may be given to active open space areas which are
devoted to improved flood control channels and areas encumbered by
flowage, floodway, or drainage easements.
(2) Active indoor space.
[a] Recreational facilities or structures and their accessory uses located in
approved areas including, but not limited to game rooms, swimming
pools, gymnasiums, bowling alleys, exercise rooms, and tennis and
racquetball courts-,
[b] Residents of the project for which the facility is planned must
automatically be members without additional charge."
Please submit a plan which outlines the areas which constitute the 1.586 acres of
recreation space.
e. 10 points are being claimed for Criterion' IV" of the Residential Uses point chart. This
-akggests that 'wiH be spent on a neighborhood public tramit facility. Please
submit a letem fi anrTfoef©rt- which states there aeceptance of the proposed facrLty
at the entr sand veriftcation eft l! easii
facility. Q61 �b
f. 10 bonus points will not be awarded for Criterion "u" of the Residential Uses point
chart. Automatic fire extinguishing systems for the dwelling units are required by the
Building Code (see Poudre Fire Authority comments).
g. The All -Development Criteria of the Land Development Guidance System are
mandatory compliance criteria. Staff feels that the land use is appropriate for this site.
However, staff is concerned about how the proposed Site Plan meets All -
Development Criteria A-2.2, A-2.4, A-2.6, A-2.7, A-2.8, and A-2.12.
8. The Water Conservation Specialist states that the final Landscape Plan will need to include
a schedule of the landscape water use categories and associated square footages.
9. The Natural Resources Department states that more information is needed on the design,
establishment, and preservation of wetlands on this site. Please contact Susie Gordon at 221-
6265 to discuss the information required.
10. Comments from the Engineering Department are attached.
11. Comments from the Stormwater Utility are attached.
12. The City Forester states that the large spruce tree along West Elizabeth needs to be
preserved. It is not currently shown on the Site Plan. The applicant should contact Tim
Buchanan at 221-6361 to schedule a meeting on site to discuss the preservation of this tree.
13. The Transportation Department states that there must be bike and pedestrian connections
from the site to the east (see Planning comment "g").
14. Transfortstated that the there is currently a weekly bus route which serves the CSU campus
that has a turnaround in Cedarwood Plaza. This bus stop must be moved out of the shopping
center and will be eliminated in January. Transfort is exploring other options at this time.
However, as stated in earlier discussions with the applicant, the proposed bus stop and
turnaround on the Jefferson Commons Site Plan does not work as the Transfort bus would
have to make an unsignalized left turn onto West Elizabeth. Please contact Gaylene Rossiter
of Transfort at 221-6195 to discuss further options.
15. The Planning Department states the following:
a. Criterion "b" of the Residential Uses point chart requires the proposed project to be
within 650 feet of an existin transit stop. Points will not be awarded for Criterion
"b" for the proposed bus stop at the entrance of Jefferson Commons.
b. Criterion "c" of the Residential Uses point chart awards points for proximity to a
existing neighborhood park; or a publicly owned but not developed neighborhood
park; or a publicly owned golf course. Points are awarded for only one or the other.
The proposed project ' ' 3,500 feet of a neighborhood park (Avery Park) and
therefore is eligible fo 20 or the applicant may claim 10 points for being within
3,500 feet of City Par golf course.
Criterion "f' of the Residential point chart references the projects proximity to a major
employment center. Please submit documentation from Poudre High School or the
Poudre R-1 School District which verifies that there are at least 100 full-time
employees at Poudre High School during a single, eight hour shift.
parking. Accessible routes shall comply with ANSI Al 17.1-1992 with running slopes
no greater than 1:20 and cross slopes no steeper than 1:48. Where routes cross lanes
for vehicle traffic they shall be designated and marked as a cross walk. Provide
parking and signs per Appendix Section 3107. Parking and access aisles shall comply
with ANSI Al 17.1-1992 with slopes no greater than 1:48 in any direction. Curb
ramps shall be provided where the accessible routes traverse curbs. Ensure that bike
racks are located to leave accessible routes unobstructed. Where accessible routes
cross lanes for vehicle traffic they shall be designated and marked as a crosswalk.
(c� Approval from the Larimer County Health Department is required for the swimming
pool. Please contact the health department at (970) 498-6775 for requirements.
d� Storage or use of hazardous materials (pool chemicals) must be in compliance with
the Fire Code and Chapter 9 of the 1991 Uniform Building Code as adopted by the
City of Fort Collins. A list of such materials with quantities and classifications should
be submitted for review at the time of building permit application.
6. The Water and Wastewater Utility states:
a. The water mains and sanitary sewer mains need to be constructed in accessible areas
such as drives, alleys, and parking areas.
b. The 6" water main in Plum Street on the south side of the property needs to be
connected (looped) with the proposed system.
c The tennis court can not be constructed on top of the sanitary sewer main.
d. Please route the drainage channel so that it is not over the existing sanitary sewer.
e. The water mains in Orchard must be connected.
f. Please add a note to the Landscape Plan which states: "Maintain a minimum
separation distance of 10 feet for trees and 4' for shrubs from any water/sewer mains
and services."
g. Please add a note that states: "Utilities to be located in the field prior to layout and
planting of landscaping."
7. Public Service of Colorado states:
a. PSC gas does not want to be limited to "rear lot" easements. Access easements on
"parking lot" sides of buildings should also be designated as utility easements.
Jx b. Gas mains will be under asphalt since there is no landscape area on the front or the
lot.
b. The Title on the Plat should read "Preliminary Plat of Jefferson Commons PUD".
C. Double row (end to end) parking stalls must be a minimum of 19' in length. Currently
these stalls vary from 17' to 18'.
d. A minimum of 12,684 square feet of interior parking lot landscaped islands (6%) are
required. Please calculate and list the percentage of interior parking lot landscaping
in the land use data. r ._
e. Please show building dimensions and distances to property lines,pn t e Site Pl4n.
on ®£ The building height shown on the elevations is approximately 47'. However,ery°t`*he
General Note on the Site Plan indicates that the maximum height is 40'. A variance
to the 40' building height limit will be required of this development (see Planning
comment "g").
g. Please add a note to the landscape note which states that "all landscaping and
irrigation systems shall be installed or secured with an irrevocable letter of credit,
escrow, or performance bond for 125% of the valuation of materials and installation
prior to the issuance of the first certificate of occupancy."
h. Please submit a plant list for the landscape plan. (c,� '0-1 w
5. The Building Inspections Department states the following:
a. Apartments accessible and adaptable for use by persons with disabilities must be
provided in accordance with Uniform Building Code Section 3103(a)8. as amended
by the City of Forty Collins. The 1992 editions of the American National Standard
Institute publication #A117.1 "Accessible and Usable Buildings and Facilities" should
be used in the design of accessible/adaptable dwelling units. A local amendment to
/ the UBC requires that accessible units with numbers of bedrooms and other amenities
be provided in numbers proportionate to the remainder of the project. When more
stringent, the Colorado revised Stature, Title 9, Article 5, Section 111 also applies to
apartment projects. Though not administered at the municipal level, similar
requirements are contained in State and Federal civil rights legislation (Fair Housing
Acts). Where provided in a project containing accessible dwellings, a portion of
garages or covered parking areas must be accessible.
b. The site shall be accessible to persons with disabilities in accordance with Uniform
Building Code Section 3103 and UBC Appendix Section 3106. Provide a designated
and marked "accessible route of travel" between all the buildings and facilities
(including mail and trash disposal) on the site; building exits and entrances and the
public way (public sidewalk); and between accessible buildings/facilities and accessible
December 15, 1995
JPI Texas Development, Inc.
c/o Rick Hattman
Gefroh Hattman Architects
145 W. Swallow Road
Fort Collins, CO 80525
Dear Rick,
Staff has reviewed your documents for the Jefferson Commons PUD, Preliminary, that were
submitted on November 20, 1995, and would like to offer the following comments:
1. The Light and Power Utility states the following:
a. A utility coordination meeting regarding this site should be held with all affected
parties bringing preliminary layouts. Kerrie Ashheak of the Engineering Department
will contact you regarding the date, time, and location of this meeting. APIWZ
b. Trees on W. Elizabeth and Orchard Place streets will need to conform to t WstrPeete" FkKkL
standards. r�oie on lar 6c� �1wr\.
C. Provisions need to be made in the two bridges for utilities to cross. Me% ko,LL, ppopip5
2. The Poudre Fire Authority states the following:
a. The proposed bridges must be capable of supporting a 35 ton fire apparatus. ffkEli!S
b. Buildings that are three or more stories in height or contain 16 or more dwelling units
must be equipped with an automated fire suppression system. —
C. The proposed security gate must be provided with an emergency access code or
knox-box key system (see Planning Department comment "g").
3. Comments from the Pleasant Valley and Lake Canal Company are forthcoming.— Kor- - 1
4. The Zoning Department states the following:
a. Don't show building envelopes on the Plat unless they are substantially larger than the
building foot print. If any portion of the buildings project outside or overhang the
building envelope, the applicant will be required to replat and vacate easements.