HomeMy WebLinkAbout620 SOUTH SHERWOOD - NCB SITE PLAN REVIEW - 51-95 - CORRESPONDENCE - (5),
ZONING, ANNEXATION AND DEVELOPMENT OF LAND
residential neighborhoods and more intensive
commercial -use areas or high traffic zones.
(Ord. No. 111, 1991, § 3, 10-1.91)
Sec. 29-209. Uses permitted.
The following uses shall be permitted in the
N-C-B District:
(1) Single-family dwellings.
(2) Two-family dwellings.
(3) Multifamily dwellings up to four (4) units,
provided no structural additions or exterior
alterations are made to the existing
building, or the dwellings are constructed
on a vacant lot or a parcel which did not
contain a structure at the time of the adop-
tion of this.Section.
(4) Boarding, rooming, and tourist homes.
(5) 011irches and uses providing meeting places
and places for public assembly with inci-
dental office space.
(6) Medical and dental clinics, professional of-
fices and personal service shops, provided
no structural additions or exterior alter-
ations are made to the existing building, or
the uses are constructed on a vacant lot or
a parcel which did not contain a structure
at the time of the adoption of this Section.
§ 29.210
contained a structure at the time of
adoption of this Section.
b. Multifamily dwellings greater than
four (4) units at up to twenty-four (24)
units per acre.
C. Parking lots and parking garages.
d. Public and nonprofit quasi -public rec.
reational uses and parks.
(12) The following uses are permitted in the
N-C-B District, provided that the intended
uses are shown on a site plan submitted to
and approved by the Planning and Zoning
Board:
a. Public and private schools for pre-
school, elementary, high school, col.
lege and university education.
b. Multifamily dwellings greater than
four (4) units greater than twenty-four
(24) units per acre.
c. Fraternity and sorority houses.
d. Medical and dental clinics, professional
offices,and personal service shoos
which. propose structural additions or
.exterior alterations to the existing
building, or the uses are to be con -
strutted on a lot or parcel which con-
tained a structure at the time of adop-
tion of this Section.
e., Undertaking establishments.
(7) Essential public utility and public service (13) Any legally permissible use which existed
installations and facilities for the protec- on a parcel of property as of the effective
tion and welfare of the surrounding area, &te of the ordinance that placed such parcel,
provided that business offices and repair of property into this zoning district, pro.
storage facilities are not included. vided that such permitted use shall be lim.
(8) Child care centers. ited to such parcel of property.
(9) Group homes.
JO) Accessory buildings and uses.
(11) The following uses are permitted within the
N-C-B District, provided that the intended
uses are shown on a site plan submitted to
and approved by the Director of Planning:
a. Multifamily dwellings up to four (4)
units which propose structural : addi-
tions or exterior alterations to the ex-
isting building, or the dwellings are to
be constructed on a lot or parcel which
"tpp. No. 19
2003
(14) Any land use located on a Planned Unit
Development plan as defined, processed and
approved according to § 29-526.
(Ord. No. 111, 1991, § 3, 10-1-91; Ord. No. 68,
1992, § 7, 7-7.92)
Sec. 29.216. Bulk and area requirements.
[The bulk and area requirements for the N-C-B
District are as follows:]
(1) Minimum lot area shall be the equivalent
to the total floor area of the building, but
10. A traffic study for this development will be required if the
proposal is submitted to the City as a P.U.D. request.
11. The proposed development will prompt the need for the alley to
be paved to the nearest public street (being either South
Sherwood or Meldrum). The pavement design must be done by an
engineer registered in the State of Colorado. A reimbursement
agreement may be written that could obligate future
development on affected adjacent properties to participate in
the cost of the alley improvements. A sidewalk must be
constructed along the public street (South Sherwood) or, in
the case of an existing sidewalk, necessary repairs must be
made._ The necessary site grading associated with this
development and any proposed fencing may have impacts on the
storm drainage patterns in the area. Please contact Kerrie
Ashbeck of the Engineering Department if you have questions
pertaining to these comments. Kerrie can be reached at 221-
6750.
12. The standard utility plan submittal requirements will apply
and a development agreement between the developer and the City
(to be executed by -the developer) is required.
13. Street oversizing fees of $584 per dwelling unit will apply
and the fees will be collected at the time of issuance of
building permits.
14. This property is located within the limits of the adopted
Westside Neighborhood Plan and falls within the "residential
redevelopment (buffer) area" of the plan. The direction for
this area is defined in the Residential, Multi -Family section,
and to some extent the East Buffer Area section, of the Land
Use Plan portion of the Westside Neighborhood Plan. The
proposal is a very intensive land use for this lot and the
surrounding neighborhood.
Also, the City is in the process of reviewing the Neighborhood
Character Design Standards and Guidelines for the Eastside and
Westside Neighborhoods in Fort Collins. This document is going
to the Planning and Zoning Board on May 22, 1995 for a
recommendation to City Council. Council will then discuss this
item on June 6 and June 20, 1995 (first and second reading).
15. The City Code requires 2 on -site parking spaces for each 3-
bedroom unit. Therefore, a minimum of 12 parking spaces are
required for this development. The concept plan shows 12
spaces; however, the handicapped space, as shown, presents a.
conflict in terms of its accessibility and usability.
16. A neighborhood meeting will be required prior to formal
submittal of a development request to the City. Please contact
Steve Olt of the Planning Department and he will assist you
with the scheduling of the time and place for this meeting.
Steve can be reached at 221-6750.
5. The City has existing single phase power in the alley behind
this property. The overhead electric lines must be
undergrounded with this development and there would be a
charge of $467.00 to the property owner for the
undergrounding. A 6' x 6' utility easement for an electric
transformer would be required at the southeast corner of the
property. The normal electric development charges would apply
to this request. Please contact Kevin Westhuis of the Light &
Power Department if you have questions pertaining to the
requirements for electric service to the property. Kevin can
be reached at (970)221-6700.
6. The City has an existing 6" water main and an 8" sanitary
sewer main in South Sherwood Street that can be used for
utility services to this property. Plant investment fees and
water rights will be collected at the time of issuance of
building permits. Please contact Roger Buffington of the
Water/Wastewater Department if you have questions pertaining
to water and sanitary sewer services to the property. Roger
can be reached at 221-6681.
7. There are City water conservation standards for irrigation
systems and landscape plans that have "recently been approved
and adopted by City Council. A copy of the ordinance is
available in the Planning Department or, if you have specific
questions about the ordinance, you can contact Jim Clark, the
City's water conservation specialist, at 221-6681.
8. The property is in the Old Town Storm Drainage Basin and any
development on the property is subject to the basin fees of
$4,150 per acre, based on the runoff coefficient for the
proposed land use. The fees can be reduced if on -site
stormwater detention is provided and approved by the
Stormwater Utility. In this case, on -site detention will be
required and the release rate will have to be for the 2 year
historic. There are no storm sewers close to this property.
Stormwater can be released into the curb and gutter system in
the street; however, no discharge can be made into the alley.
The underground Arthur Ditch touches a corner of this property
and this may have an affect on necessary improvements to the
alley. The standard requirements for a drainage report,
grading and drainage plan, and erosion control plan to be
submitted to the City will apply to this development. Please
contact Glen Schlueter if you have questions pertaining to
storm drainage related to this property. Glen can be reached
at 221-6589.
9. Parkland fees of $779 per dwelling unit will apply to this
development and the fees will be collected at the time of
issuance of building permits. The fees are presently being
evaluated by the Parks & Recreation Department and it is
probable that they will increase by approximately 4.5%
sometime this year.
4ftCONCEPTUAL REVIEW STAFF COMMENTS
City of Fort Collins
MEETING DATE: May 1, 1995
ITEM: 620 South Sherwood Street
APPLICANT: Mark Cucarola
Midwestern Homes Company
P.O. Box 280024
Lakewood, CO. 80228
LAND USE DATA:
Request for a 6-plex multi -family' residential building (with
associated parking) on the lot at 620 South Sherwood Street. Each
unit is to contain 3 bedrooms.
COMMENTS:
1. The property is in the NCB - Neighborhood Conservation Buffer
Zoning District. The proposed use is permitted in this
District, provided that the intended use is shown on a Site
Plan that is submitted to the City for review and approval by
the Planning and Zoning Board [see attached copy of Section
29-209(12)b of the City Code]. The lot is 50' x 190' = 9,500
square feet, or 0.22 acre, in size. The proposed 6 dwelling
units on a 0.22 acre site = a density of 27 dwelling units per
acre. As the Code states: "Multi -family dwellings greater than
four (4) units greater than twenty-four (24) units per acre',
must be approved by the Planning and Zoning Board.
2. All ground floor units must be handicapped accessible.
3. The 8' side yard setback on the south side (as shown on the
concept plan) is probably not enough. The staircases are
considered to be part of the building and, therefore, the
required setback of 1' for each 3' of building height (for a
multi -family use) must be from the outside of the staircases.
A variance to this requirement would have to be done by
request to the Zoning Board of Appeals or through the planned
unit development (P.U.D.) process that requires approval by
the Planning and Zoning Board.
4. The proposed building may have to be equipped with an
automatic fire sprinkler system. Please contact Mike Pretz of
the Poudre Fire Authority for assistance in determining if a
sprinkler system is required. Mike can be reached at (970)221-
6570.
ENVIRONMENTAL SERVICES 281 NORTH COLLEGE P.O.BOX 580 FORT COLLINS, COLORADO 80522-0580 (303)221-0750
PLANNING DEPARTMENT
Com: -tity Planning and Environmen .iervices
Current Planning
Citv of Fort Collins
May 4, 1995
Mark Cucarola
Midwestern Homes Company
P.O. Box 280024
Lakewood, CO. 80228
Dear Mark:
For your information, attached is a copy of the Staff's comments
concerning the request for 620 South Sherwood Street, which was
presented before the Conceptual Review Team on May 1, 1995.
This is a request for a 6-plex multi -family residential building
(with associated parking) on the lot at 620 South Sherwood Street.
Each unit is to contain 3 bedrooms.
The comments are offered informally by Staff to assist you in
preparing the detailed components of the project application.
Modifications and additions to these comments may be made at the
time of formal review of this project.
If you should have any questions regarding these comments or the
next steps in the review process, please feel free to call me at
221-6750.
Sincerely,
oo
4tvtej Olt
Project Planner
cc: Stormwater Utility
Transportation Department
File
281 North College Avenue • P.O. Box 580 Fort Collins, CO 80522-0580 • (303) 221-6750